Home > Panasonic > Air Conditioner > Panasonic Cs A7dkd Cs A9dkd Cs A12dkd Repair Manual

Panasonic Cs A7dkd Cs A9dkd Cs A12dkd Repair Manual

Here you can view all the pages of manual Panasonic Cs A7dkd Cs A9dkd Cs A12dkd Repair Manual. The Panasonic manuals for Air Conditioner are available online for free. You can easily download all the documents as PDF.

Page 1

 1 Features 2
 2 Functions 
3
 2.1. Remote Control 
3
 2.2. Indoor Unit 
4
 2.3. Outdoor Unit 
5
 3 Product Specifications 
6
 3.1. CS-A7DKD CU-A7DKD 
6
 3.2. CS-A9DKD CU-A9DKD 
8
 3.3. CS-A12DKD CU-A12DKD 
10
 4 Dimensions 
12
© 2005 Panasonic HA Air-Conditioning (M) Sdn Bhd
(11969-T). All rights reserved. Unauthorized copying
and distribution is a violation of law.
CS-A7DKD CU-A7DKD
CS-A9DKD CU-A9DKD
CS-A12DKD CU-A12DKD
 4.1. Indoor Unit & Remote Control 12
 4.2. Outdoor Unit 
13
 5 Refrigeration Cycle...

Page 2

 8.4. Automatic Operation 22
 8.5. Operation Control 
23
 8.6. Indoor Fan Speed Control 
30
 8.7. Outdoor Fan Speed Control 
32
 8.8. Vertical Airflow Direction Control 
32
 8.9. Horizontal Airflow Direction Control 
33
 8.10. Powerful Operation 
33
 8.11. Quiet Operation 
35
 8.12. Ionizer Operation 
37
 8.13. Timer Control 
38
 8.14. Random Auto Restart Control 
38
 8.15. Remote Control Signal Receiving Sound  
38
 9 Operating Instructions 
39
 10  Installation Instructions 
45
 10.1. Safety...

Page 3

2 Functions
2.1. Remote Control
3
CS-A7DKD CU-A7DKD / CS-A9DKD CU-A9DKD / CS-A12D KD CU-A12D KD / 

Page 4

2.2. Indoor Unit
Automatic Operation Button
• Press for < 5 second to operate Automatic
operation mode. Used when the remote control
cannot be used.
• Press for ≥ 5 second to operate Cooling
operation mode and compressor force to on
(“beep” sound will heard). Used when test
running or servicing.
• Within 20 second of Cooling operation, press
continuously for 5 second to enter various
setting mode. “beep, beep” sound will be heard.
(Used to toggle remote control signal receiving
sound or select remote...

Page 5

2.3. Outdoor Unit
5
CS-A7DKD CU-A7DKD / CS-A9DKD CU-A9DKD / CS-A12D KD CU-A12D KD / 

Page 6

3 Product Specifications
3.1. CS-A7DKD CU-A7DKD
UnitIndoor UnitOutdoor Unit
Power Source (Phase, Voltage, Cycle)ø, V, HzSingle, 220 - 230, 50
Cooling CapacitykW (BTU/h)2.00 - 2.00 (6,820 - 6,820)
Heating CapacitykW (BTU/h)2.10 - 2.10 (7,160 - 7,160)
Moisture Removall/h (Pint/h)1.3 (2.7)
Airflow MethodOUTLET
INTAKE
SIDE VIEWTOP VIEW
Air VolumeLom3/min (cfm)Cooling; 5.8 (205) - 5.8 (205)
Heating; 6.2 (219) - 6.2 (219)—
Mem3/min (cfm)Cooling; 6.8 (241) - 6.8 (241)
Heating; 6.8 (241) - 6.8 (241)—
Him3/min...

Page 7

UnitIndoor UnitOutdoor Unit
Fan MotorDescriptionCross-flow FanPropeller Fan
MaterialAS + Glass Fiber 20%PP Resin
TypeInduction (4-poles)Induction (6-poles)
InputW60.5 - 66.066 - 74.8
RatedOutputW1530
Fan SpeedLowrpmCooling; 780 - 780
Heating; 840 - 840—
MediumrpmCooling; 920 - 920
Heating; 920 - 920—
HighrpmCooling; 1,050 - 1,050
Heating; 1,220 - 1,220800 - 830
SuperHighrpmCooling; 1,220 - 1,220
Heating; ——
Heat ExchangerDescriptionEvaporatorCondenser
Tube materialCopperCopper
Fin materialAluminium (Pre...

Page 8

3.2. CS-A9DKD CU-A9DKD
UnitIndoor UnitOutdoor Unit
Power Source (Phase, Voltage, Cycle)ø, V, HzSingle, 220 - 230, 50
Cooling CapacitykW (BTU/h)2.65 -2.65 (9,040 - 9,040)
Heating CapacitykW (BTU/h)2.80 - 2.85 (9,550 - 9,720)
Moisture Removall/h (Pint/h)1.6 (3.4)
Airflow MethodOUTLET
INTAKE
SIDE VIEWTOP VIEW
Air VolumeLom3/min (cfm)Cooling; 5.8 (204) - 5.8 (204)
Heating; 6.2 (220) - 6.2 (220)—
Mem3/min (cfm)Cooling; 7.1 (251) - 7.1 (251)
Heating; 7.1 (251) - 7.1 (251)—
Him3/min (cfm)Cooling; 8.6 (300) -...

Page 9

UnitIndoor UnitOutdoor Unit
Fan MotorDescriptionCross-flow FanPropeller Fan
MaterialAS + Glass Fiber 20%PP Resin
TypeInduction (4-poles)Induction (6-poles)
InputW60.5 - 66.066 - 74.8
RatedOutputW1530
Fan SpeedLowrpmCooling; 780 - 780
Heating; 840 - 840—
MediumrpmCooling; 960 - 960
Heating; 960 - 960—
HighrpmCooling; 1,160 - 1,160
Heating; 1,270 - 1,270800 - 830
SuperHighrpmCooling; 1,270 - 1,220
Heating; ——
Heat ExchangerDescriptionEvaporatorCondenser
Tube materialCopperCopper
Fin materialAluminium (Pre...

Page 10

3.3. CS-A12DKD CU-A12DKD
UnitIndoor UnitOutdoor Unit
Power Source (Phase, Voltage, Cycle)ø, V, HzSingle, 220 - 230, 50
Cooling CapacitykW (BTU/h)3.52 - 3.54 (12,000 - 12,100)
Heating CapacitykW (BTU/h)4.00 - 4.05 (13,650 - 13,810)
Moisture Removall/h (Pint/h)2.0 (4.2)
Airflow MethodOUTLET
INTAKE
SIDE VIEWTOP VIEW
Air VolumeLom3/min (cfm)Cooling; 6.7 (236) - 6.7 (236)
Heating; 7.1 (251) - 7.1 (251)—
Mem3/min (cfm)Cooling; 8.3 (294) - 8.3 (294)
Heating; 8.3 (293) - 8.3 (293)—
Him3/min (cfm)Cooling; 9.5...