UnitIndoor UnitOutdoor Unit
Fan MotorDescriptionCross-flow FanPropeller Fan
MaterialAS + Glass Fiber 20%PP Resin
MotorTypeInduction (4-poles)Induction (6-poles)
InputW60.5 - 66.071.5 - 80.3
RatedOutputW1531
Fan SpeedLowrpmCooling; 900 - 900
Heating; 960 - 960—
MediumrpmCooling; 1,120 - 1,120
Heating; 1,120 - 1,120—
HighrpmCooling; 1,280 - 1,280
Heating;1,310 - 1,310845 - 860
SuperHighrpmCooling; 1,310 - 1,310
Heating; ——
Heat ExchangerDescriptionEvaporatorCondenser
Tube materialCopperCopper
Fin...

Page 12

4 Dimensions
4.1. Indoor Unit & Remote Control
12
CS-A7DKD CU-A7DKD / CS-A9DKD CU-A9DKD / CS-A12D KD CU-A12D KD / 

Page 13

4.2. Outdoor Unit
4.2.1. CU-A7DKD / CU-A9DKD
4.2.2. CU-A12DKD
13
CS-A7DKD CU-A7DKD / CS-A9DKD CU-A9DKD / CS-A12D KD CU-A12D KD / 

Page 14

5 Refrigeration Cycle Diagram
14
CS-A7DKD CU-A7DKD / CS-A9DKD CU-A9DKD / CS-A12D KD CU-A12D KD / 

Page 15

6 Block Diagram
15
CS-A7DKD CU-A7DKD / CS-A9DKD CU-A9DKD / CS-A12D KD CU-A12D KD / 

Page 16

16
CS-A7DKD CU-A7DKD / CS-A9DKD CU-A9DKD / CS-A12D KD CU-A12D KD / 

Page 17

7 Wiring Diagram
17
CS-A7DKD CU-A7DKD / CS-A9DKD CU-A9DKD / CS-A12D KD CU-A12D KD / 

Page 18

18
CS-A7DKD CU-A7DKD / CS-A9DKD CU-A9DKD / CS-A12D KD CU-A12D KD / 

Page 19

8 Operation Details
8.1. Heating Operation
 • Heating operation can be set using remote control.
 • This operation is applied to warm the room temperature reaches the setting temperature set on the remote control.
 • The remote control setting temperature, which takes the reading of intake air temperature sensor, can be adjusted from 16°C
to 30°C.
 • During heating operation, the compressor will stoprunning and restart as shown in below figure.
8.1.1. Heating Operation Time Diagram
19
CS-A7DKD CU-A7DKD /...

Page 20

8.2. Cooling Operation
 • Cooling operation can be set using remote control.
 • This operation is applied to cool down the room temperature reaches the setting temperature set on the remote control.
 • The remote control setting temperature, which takes the reading of intake air temperature sensor, can be adjusted from 16°C
to 30°C.
 • During cooling operation, the compressor will stoprunning and restart as shown in below figure.
8.2.1. Cooling Operation Time Diagram
20
CS-A7DKD CU-A7DKD / CS-A9DKD...