Panasonic Cs A7dkd Cs A9dkd Cs A12dkd Repair Manual
Have a look at the manual Panasonic Cs A7dkd Cs A9dkd Cs A12dkd Repair Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
UnitIndoor UnitOutdoor Unit Fan MotorDescriptionCross-flow FanPropeller Fan MaterialAS + Glass Fiber 20%PP Resin MotorTypeInduction (4-poles)Induction (6-poles) InputW60.5 - 66.071.5 - 80.3 RatedOutputW1531 Fan SpeedLowrpmCooling; 900 - 900 Heating; 960 - 960— MediumrpmCooling; 1,120 - 1,120 Heating; 1,120 - 1,120— HighrpmCooling; 1,280 - 1,280 Heating;1,310 - 1,310845 - 860 SuperHighrpmCooling; 1,310 - 1,310 Heating; —— Heat ExchangerDescriptionEvaporatorCondenser Tube materialCopperCopper Fin materialAluminium (Pre Coat)Aluminium (Blue Coat) Fin TypeSlit FinCorrugated Fin Row / Stage(Plate fin configuration, forced draft) 2×152×24 FPI2116 Size (W × H × L)mm610 × 315 × 25.4720× 504 × 36.38 Refrigerant Control Device—Capillary Tube Refrigeration Oil(cm3)—ATMOS M0 OR SUNISO 4GDID Refrigerant (R-22)g (oz)—1,080 (38.1) Thermostat—— Protection Device—— Capillary TubeLengthmm—Cooling; 630, Heating; 455 Flow Ratel/min—Cooling; 6.5, Heating; 13.6 Inner Diametermm—Cooling; 1.2 Heating; 1.5 Air FilterMaterial StyleP.P. Honeycomb— Capacity ControlCapillary Tube Compressor CapacitorµF, VAC—35 µF, 370VAC Fan Motor CapacitorµF, VAC1.5 µF, 440VAC2.0 µF, 440VAC Note: • Specifications are subjected tochange without prior notice for further improvement. 11 CS-A7DKD CU-A7DKD / CS-A9DKD CU-A9DKD / CS-A12D KD CU-A12D KD /
4 Dimensions 4.1. Indoor Unit & Remote Control 12 CS-A7DKD CU-A7DKD / CS-A9DKD CU-A9DKD / CS-A12D KD CU-A12D KD /
4.2. Outdoor Unit 4.2.1. CU-A7DKD / CU-A9DKD 4.2.2. CU-A12DKD 13 CS-A7DKD CU-A7DKD / CS-A9DKD CU-A9DKD / CS-A12D KD CU-A12D KD /
5 Refrigeration Cycle Diagram 14 CS-A7DKD CU-A7DKD / CS-A9DKD CU-A9DKD / CS-A12D KD CU-A12D KD /
6 Block Diagram 15 CS-A7DKD CU-A7DKD / CS-A9DKD CU-A9DKD / CS-A12D KD CU-A12D KD /
16 CS-A7DKD CU-A7DKD / CS-A9DKD CU-A9DKD / CS-A12D KD CU-A12D KD /
7 Wiring Diagram 17 CS-A7DKD CU-A7DKD / CS-A9DKD CU-A9DKD / CS-A12D KD CU-A12D KD /
18 CS-A7DKD CU-A7DKD / CS-A9DKD CU-A9DKD / CS-A12D KD CU-A12D KD /
8 Operation Details 8.1. Heating Operation • Heating operation can be set using remote control. • This operation is applied to warm the room temperature reaches the setting temperature set on the remote control. • The remote control setting temperature, which takes the reading of intake air temperature sensor, can be adjusted from 16°C to 30°C. • During heating operation, the compressor will stoprunning and restart as shown in below figure. 8.1.1. Heating Operation Time Diagram 19 CS-A7DKD CU-A7DKD / CS-A9DKD CU-A9DKD / CS-A12D KD CU-A12D KD /
8.2. Cooling Operation • Cooling operation can be set using remote control. • This operation is applied to cool down the room temperature reaches the setting temperature set on the remote control. • The remote control setting temperature, which takes the reading of intake air temperature sensor, can be adjusted from 16°C to 30°C. • During cooling operation, the compressor will stoprunning and restart as shown in below figure. 8.2.1. Cooling Operation Time Diagram 20 CS-A7DKD CU-A7DKD / CS-A9DKD CU-A9DKD / CS-A12D KD CU-A12D KD /