Panasonic Convertible Camera Aw E600 Operating Instructions
Have a look at the manual Panasonic Convertible Camera Aw E600 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
-29- nMENU ITEM SETTING• Each of the four use modes of the camera has a main menu. (Shown at right) • Each item of the main menu has a submenu, which consists of several settings. • These settings have been preset to the optimum values to suit each use mode, and can be changed to suit actual shooting conditions. • They can be set from the camera and RCU (RCB). They can also be set from the hybrid control panel using the switches, but the setting items are limited because the menu is not shown. Notes: • Composite signals are output from the video output regardless of the position ENC/VF of the RCU (RCB) user set switch. • [End] is displayed only in setting from the cam- era alone. lMAIN MENU SCREEN MENU ITEM SETTING **Halogen Mode Set** Brightness Set Color Set G/L. Color Bar Set Sharpness Set Other Set Initialize Data End Use ModeBlinking **User Mode Set** Iris, Shutter, Gain Set Color Set G/L. Color Bar Set Detail Set1 Detail Set2 Color Matrix Set Other Set Initialize Data EndMain Menu of Halogen, Fluorescent, Outdoor Mode Main Menu of User Mode
-30- nSETTING1. From the camera alone: Keep the MENU switch depressed for 5 sec- onds or more. From RCU (RCB): Set the user set switch in the pocket to the ON position. The main menu appears on the monitor screen. 2. Each time the MENU switch (M), ITEM/AWC switch (
-31- • Settings enclosed in parentheses can be set with the RCU (RCB) switch or VR in RCU (RCB) mode. • To return to the initial settings, refer to page 46.nSUB MENU (Halogen Mode, Fluorescent Mode, Outdoor Mode) **Brightness Set** Picture Level ±0 Light PEAK/AVG 0 Light Area Top cut Auto ND (ELC) (OFF) Auto Gain Up (OFF) Manu Gain Up (0dB) Pedestal (±0) Contrast(Gamma) MID Return **G/L. Color Bar Set** H Phase ±0 SC Coarse (1) SC Fine (±0) Color Bar Set (7.5IRE) Return **Other Set** Shutter Speed (OFF) Syncro Scan --- V Resolution Normal Baud Rate 9600bps Nega/Posi Posi Return **Color Set** Chroma Level ±0 Flesh Tone ±0 White Bal (AWC A) Highlight Chroma OFF Return **Sharpness (DTL) Set** DTL Select Sharpness Level (HIGH) Noise Suppress OFF Clean DNR OFF DTL Flesh Tone MID Return
• ON is automatically selected when the electronic shutter @2 on the submenu [Other Set] is set to [Auto ND]. OFF is selected when other than [Auto ND] is selected. • ON is selected when the SHUTTER switch is set to [ELC] in RCU (RCB) mode, and OFF is select- ed when it is set to other than [ELC]. -32- nSetting and Changing of the Setting (Halogen Mode, Fluores- cent Mode, Outdoor Mode)qVideo Level Adjustment [Picture Level: –50 - +50] Convergence level of AUTO IRIS/AUTO GAIN UP/ AUTO ND (ELC) can be adjusted. wDetecting Ratio Adjustment [Light PEAK/AVG: P50 - A50] The ratio of AUTO IRIS/AUTO GAIN UP/AUTO ND (ELC) detected peak to average can be adjusted within a predetermined range. ePhotometric Measurement Method Setting [Light Area: All, Center, Top cut, BTM cut, R/L cut A photometric measurement method can be select- ed for AUTO IRIS/AUTO GAIN UP/AUTO ND (ELC). All:All the screen area is measured. Center:The screen is measured mainly in the cen- ter area, about one-third of both the top and bot- tom and one-third of both the right and left por- tions of the screen are excluded from measure- ment. Top cut:About one-third of the top part of the screen is excluded from measurement. BTM cut:About one-third of the bottom portion of the screen is excluded from measurement.rAuto ND (ELC) Setting [Auto ND (ELC): ON/OFF] ON:The electronic shutter is controlled to automati- cally adjust the luminance. OFF:Luminance is not automatically adjusted by the electronic shutter. All Center Top cut BTM cut R/L cut SHUTTER RCU (RCB) R/L cut:About one-third of both the right and left portions of the screen are excluded from mea- surement. Notes R B R B PED TOTAL PED A BATW AWCAUTOHOLD ABC IRISMAN AUTO 1000 S/S ELC 500 100 OFF SHUTTER SCENE 21 3 USER SET AUTO/ATW PAINTINGGAIN
• In case of settings on the camera alone or when the iris switch on the RCU (RCB) is at [AUTO], the Auto Gain Up control may not operate if the lens iris switch is in the manual position. • When the AGC switch on the hybrid control panel is set to AGC, the Auto Gain Up control operates in the HIGH position. POWEROPERATE BAR CAMMODEGAIN AWC SCENE FILEABC AT W A B AUTO/AIW ELC LOW MID MANUON SC H OFF HIGH AGC OFF 1 / 100SHUTTER ON OFF 1 . 2 . 3 . 4 . G/L PHASE T.PED CABLE COMP 90¡ 180¡ 0¡ 270¡ YC -33- tAuto Gain Up Control Setting [Auto Gain Up: OFF/ LOW/HIGH] LOW:The Auto Gain Up control with a maximum gain increase of about 18 dB adjust the lumi- nance automatically. HIGH:The Auto Gain Up control with a maximum gain increase of about 30 dB operates. If the luminance is still insufficient, the Night Eye also operates to adjust the luminance automatically. OFF:No auto gain up takes place. (Gain can be increased manually.) Hybrid Control Panel AGC yManual Gain Up Control Setting [Manu Gain Up: 0 dB - 30 dB / N/Eye L / N/Eye H] Manual setting is possible only when the Auto Gain Up control is in the OFF position. 0 dB:0 dB should be selected in normal cases. 1 dB - 30 dB:Use this range if sufficient video out- put cannot be obtained even when the lens iris is opened in shooting dark scenes. N/Eye L / N/Eye H (Night Eye L/H):Use this mode if sufficient video output cannot be obtained even if 30 dB gain up should be selected. Night Eye can be selected to any of two (L or H) levels. Hybrid Control Panel Manual GAIN Notes • Only 0 dB, 9 dB, or 18 dB can be selected in case of using the RCU (RCB). • 0 dB when the manual GAIN switch on the hybrid control panel is at LOW, 9 dB when it is at MID, or 18 dB when it is at HIGH. POWEROPERATE BAR CAMMODEGAIN AWC SCENE FILEABC AT W A B AUTO/AIW ELC LOW MID MANUON SC H OFF HIGH AGC OFF 1 / 100SHUTTER ON OFF 1 . 2 . 3 . 4 . G/L PHASE T.PED CABLE COMP 90¡ 180¡ 0¡ 270¡ YC Notes
-34- uBlack Level Setting [Pedestal: –30 - +30] The black level (pedestal) of the luminance (Y) sig- nal can be set. Used in adjusting the black levels of two or more cameras. iContrast Adjustment [Contrast (Gamma): LOW/MID/HIGH] Contrast can be adjusted to any of three levels. oChroma Level Adjustment [Chroma Level: –3 - +3] Chroma Level can be decreased or increased to any of three levels each. !0Skin Color Adjustment [Flesh Tone: –3 - +3] Skin color can be decreased or increased to any of three levels each. !1White Balance Setting [White Bal: ATW/AWC A/ AWC B/P SET 3 200K/P SET 5 600K] ATW:The white balance is automatically adjusted to be always right. AWC A, AWC B:Once the white balance is adjust- ed with the ITEM/AWC switch on the back of the camera, it is no longer necessary to set the white balance again if you simply select AWC A or AWC B, provided that the camera is used under the same conditions.Fine color adjustment can be made after setting AWC by red/blue gain adjustment in user mode or from the RCU (RCB). P SET 3 200K:The white balance is adjusted to 3 200K illumination. P SET 5 600K:The white balance is adjusted to 5 600K illumination. !2Highlight Chroma Setting [Highlight Chroma: OFF/LOW/HIGH] At LOW or HIGH, the color dynamic range widens to prevent highlighted white portions from suppres- sion. !3Horizontal Phase Adjustment [H Phase: –206 - +49] Horizontal phase can be adjusted when a genlock signal is supplied. !4Sub Carrier Phase Coarse Adjustment [SC Coarse: 1/2/3/4] Coarse adjustment of subcarrier phase can be made when a genlock signal is supplied. Neither P SET 3 200K nor P SET 5 600K can be set from the RCU (RCB) or the hybrid control panel. Note
-35- Neither Sharpness nor Super DTL is valid for con- tour correction if Detail Level setting !8is in the OFF position.!8Detail Level Setting [Level: OFF/LOW/HIGH] Detail level can be adjusted when Detail Select set- ting !7is at Sharpness. Super DTL level can be adjusted when it is at Super DTL. In case of using the RCU (RCB), the above can be adjusted with the contour correction switch (DTL). IRISMAN AUTO 1000 S/S ELC 500 120 OFF SHUTTER SCENE 21 3 USER SET OFFON +18 +9 0(dB)+6 OFF -6(dB) GAIN BAR CAMHIGH LOW OFF RCBDTL AGC R B R B PED TOTAL PED A BATW AWCAUTOHOLD ABC AUTO/ATW PAINTINGGAINRCU (RCB) DTL !5Subcarrier Phase Fine Adjustment [SC Fine: –511 - +511] Fine adjustment of subcarrier phase can be made when a genlock signal is supplied. !6Color Bar Setup Setting [Color Bar Set: 0.0IRE/7.5IRE] The setup level of color bar can be adjusted. !7Detail Select Setting [DTL Select: Sharpness/ Super DTL] If contour correction is not sufficient at the Sharpness position when Detail Level setting !8is set to LOW or HIGH, select the Super DTL position. !9Noise Suppress Level Setting [Noise Suppress: OFF/LOW/HIGH] Screen noise can be reduced when Detail Level setting !8is at HIGH or LOW. @0Clean DNR Setting [Clean DNR: OFF/LOW/HIGH] Clean DNR effect can be selected. @1Detail Flesh Tone Level Setting [DTL Flesh Tone: LOW/MID/HIGH] LOW:Skin color coarseness is suppressed. MID:Standard HIGH:Skin color is emphasized. Note
Shutter Speed OFF 1/100 1/250 1/500 1/1 000 1/2 000 1/4 000 1/10 000 -36- @2Electronic Shutter Setting [Shutter Speed: OFF/ 1/100 to 1/10 000 / S/Scan / Auto ND] OFF:Electronic shutter is turned off. 1/100, 1/250, 1/500, 1/1 000, 1/2 000, 1/4 000, 1/10 000: Electronic shutter operates at one of these speeds as selected. S/Scan (Synchro Scan):Electronic shutter oper- ates at the speed set with the electronic shutter synchro-scan setting @3. Auto ND:Electronic shutter is controlled to auto- matically adjust the luminance. (ELC)@3Electronic Shutter Synchro-Scan Setting [Synchro Scan: 60.34 Hz - 15.75 kHz] This setting is possible only when Electronic Shutter setting @2is at S/Scan. Horizontal bar noise can be reduced by synchro- scan adjustment in shooting workstation scenes, for example. *For luminance settings at each shutter speed and synchro-scan shutter speed, refer to the table below. Required luminance ratio 1 2 4 8 16 32 64 160 Synchro-scan -99.68 Hz 250.0 Hz 492.2 Hz 984.4 Hz 1.969 kHz 3.938 kHz 7.875 kHz @4CCD Read Out Mode Setting [V Resolution: Normal/Fine] Normal:Normal image. (CCD storage will be by field storage.) Fine:Vertical resolution increases. (Vertical resolu- tion is raised without increasing residual images by frame storage and electronic shutter. Normal is recommended for general use be- cause sensitivity will decrease at the Fine set- ting. • In case of using the RCU (RCB), none of the shut- ter speeds-1/250, 1/2 000, 1/4 000, and 1/10 000 can be selected. • In case of using the hybrid control panel, only OFF, 1/100, or Auto ND (ELC) can be selected. • If the lens iris switch is at M (Manual) when oper- ating the camera alone or when the iris switch on the RCU (RCB) is at AUTO, Auto ND may not function. Set the lens iris switch to A (Auto). • Flickering may increase at Auto ND under fluores- cent lights. • Auto ND is automatically selected if Auto ND (ELC) setting ris set to ON.Notes
-37- @5PC Control Access Speed Setting [Baud Rate: 1 200 bps/2 400 bps/4 800 bps/9 600 bps] Select a communication speed in controlling the camera from the computer.@ 65Negative/Positive Selection [Nega/Posi: Posi/Nega] Posi:Normal image Nega:Image is shown reversed in darkness and color. When an option card is added, only the composite output and Y/C output will be reproduced in nega- tive image.Note
-38- nSub Menu (User Mode) **Iris, Shutter, Gain Set** Picture Level ±0 Light PEAK/AVG 0 Light Area Top cut Auto Iris Adjust OFF Shutter Mode (Step) Step (OFF) Syncro Scan --- Field/Frame Field Gain (0dB) Pedestal (±0) Return **Detail Set1** Detail (HIGH) H Detail Level H +11 V Detail Level H +12 H Detail Level L +7 V Detail Level L +6 Detail Band 2 Noise Suppress 3 Level Dependent 0% Dark Detail 0 Return **Color Matrix Set** Matrix(R-G) ±0 Matrix(R-B) ±0 Matrix(G-R) ±0 Matrix(G-B) ±0 Matrix(B-R) ±0 Matrix(B-G) ±0 Return **Color Set** Chroma Level ±0 White Bal (AWC A) Highlight Chroma OFF Painting R Gain (±0) B Gain (±0) R Pedestal (±0) B Pedestal (±0) 2D LPF OFF Return **Detail Set2** Chroma Detail 0 DTL Flesh Tone MID Corner Detail OFF Precision Detail OFF Return **Other Set** Gamma 0.45 Knee Point 88% White Clip 110% Flare R 0 Flare G 0 Flare B 0 Black Stretch OFF Clean DNR OFF Baud Rate 9600bps Nega/Posi Posi Return **G/L. Color Bar Set** H Phase (±0) SC Coarse (1) SC Fine (±0) Color Bar Set 7.5IRE Return • Settings enclosed in parentheses can be set with the RCU (RCB) switch or VR in RCU (RCB) mode. • To return to the initial settings, refer to page 46.