    Have a look at the manual Panasonic Convertible Camera Aw E600 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							-9-
    13. Cable Clamp
    Clamp the DC Power Supply Cable (AW-CA4T1)
    connected to the DC 12 V Input Connector to pre-
    vent it from slipping out.
    14. G/L Input Connector (G/L IN)
    Signals synchronized with the reference signal are
    to be supplied to this connector when the camera is
    to be synchronized with the reference signal BB.
    15. Optional Card Slot
    Slot for inserting an optional card.  For details, refer
    to the manual for optional cards. 12. DC 12 V Input Connector (DC 12V IN)
    12 V DC is supplied through the optional DC power
    supply cable (AW-CA4T1). 
    						
    							-10-
    • Lenses of any make can be mounted on the cam-
    era as long as they are equipped with a 1/2” stan-
    dard bayonet.
    • Use the lens extension cable WV-CA12T12 (6”/
    15 cm) if your lens cable is too short.
    VIDEO OUTG/L INI/F REMOTE OPTION CARDIRIS
    DC12V IN
    MENUITEM/AWCYES/ABCNO/BAR
    Control Cable
    To Lens I/F Connector of
    Camera Pan/tilt Unit
    Camera Cable
    1. Lens Mounting
    Rotate the lens fixing ring knob counterclockwise
    and remove the lens mount cap. Mount the lens on
    the camera and rotate the lens fixing ring knob
    clockwise in order to fix the lens securely. Connect
    the camera cable to the IRIS connector on the back
    panel of the camera.
    MOUNTING 
    						
    							-11-
    2. Fix the camera mounting base, pan/tilt unit, and tri-
    pod securely in the screw hole (1/4-20UNC) of the
    camera mounting adaptor.
    3. If the camera cannot be securely fixed, stick the
    supplied rubber sheet to the mounting adaptor,
    then mount the camera.
    Mounting adaptor
    2. Camera Mounting1. Fix the mounting adaptor to the top or bottom of the
    camera.
    Camera Mounting Bracket (WV-831) 
    						
    							-12-
    1. Fully open the iris by shooting a dark object.  (Iris
    selection switch should be set to M.)
    2. Loosen the flange back lock knob.
    3. Aim the camera at any object over 2 meters away
    from the camera.
    4. Set the lens to its TELE end first and adjust its focus
    with the focus ring.
    5. Set the lens to its widest angle next and adjust its
    focus with the flange back adjust ring.
    6. Adjust the focus ring and the flange back adjust
    ring alternately for the best focus within the zoom-
    ing range.
    Tighten the flange back lock knob upon completion
    of focusing.
    7. Turn the iris selection switch to Position A.
    Convertible  Camera AW –
    E600 E600
    Flange back lock knob FOCUS Ring
    Flange back adjust ring
    FLANGE BACK ADJUSTMENT (FOR ZOOM LENS) 
    						
    							-13-
    IRIS GAIN CONTROL IN A LENSAn iris gain control hole is usually provided in the front
    of the lens. Adjustment of the iris gain, with a screwdriv-
    er through the hole may be done as follows.  (Shape
    and location of the hole may vary depending on the
    type of lens.)
    1. Turn the iris selection switch to Position A (AUTO).
    2. Rotate the iris gain control to the maximum gain,
    but in a range where no hunting or oscillating of the
    iris ring develops.
    Iris gain control (G, S)
    Automatic iris power zoom lens 
    						
    							-14-
    Caution:
    The connection and installation should be done by qualified service personnel or system installers.
    Refer any servicing to qualified service personnel.CONNECTIONS
    VIDEO OUTG/L INI/F REMOTE OPTION CARDIRIS
    DC12V IN
    MENUITEM/AWCYES/ABCNO/BAR
    ONPOWER
    OFFPOWERO    I
    FUSE(POWER)
    125V  3.15AFUSEFUSE
    AC Adaptor  
    AW-PS505
    nCONNECTION OF DEVICE WITH A COMPOSITE INPUT CONNECTOR1. Connect this to a DC 12 V class 2 power supply only.
    2. To prevent fire or shock, the UL listed wire VW-1, style 1007 should be used as for the cable for DC 12 V Input
    Connector.Cautions • Connection to any device which has a composite input connector, such as a video monitor or a VCR, must be made
    through the VIDEO OUT Connector.
    • Power supply to the camera must be through the optional DC power supply Cable AW-CA4T1.
    • For DC power supply, use the optional AC adaptor AW-PS505.
    VIDEO OUT
    Connector
    Video monitor
    AC Adaptor AW-PS505
    VIDEO IN
    75 ½coaxial cable
    DC Power supply
    Cable AW-CA4T1 
    						
    							-15-
    GEN-LOCK GEN-LOCKINAUX
    AUXINAUTO
    AUTO75¶/Hi-Z
    /Hi-ZAUTO
    AUTO75¶/Hi-Z
    /Hi-ZR/PR /C
    R/PR /C
    OUT
    OUTOUT
    OUT
    AUDIO AUDIOSEE MANUAL
    SEE MANUAL
    VIDEO 1
    VIDEO 1
    G/Y/Y G/Y/YVIDEO 2
    VIDEO 2
    B/PB /B B/PB /BSYNC
    SYNCS-VIDEO
    S-VIDEO
    14
    23TALLY
    TALLY
    CAMERA (MULTI)
    CAMERA (MULTI)
    CABLE SELECT CABLE SELECT
    FUSE
    FUSE250V  1.25A
    250V  1.25A
    TALK
    TALK
    INCOM INCOM
    RECEIVE RECEIVECONTROL
    CONTROLTALLY & INCOM
    TALLY & INCOM
    MULTIOVP
    OVP
    MPX MPX
    MPX
    MPX OUTPUT OUTPUT
    VIDEO OUTG/L INI/F REMOTE OPTION CARDIRIS
    DC12V IN
    MENUITEM/AWCYES/ABCNO/BAR
    Connection to the RCU (WV-RC700A,WV-RC550) is
    made through the optional RCU cable AW-CA50A26.
    1. Turn RCU power off before connecting cables.
    2. Set the cable selection switch of the RCU to MULTI
    (in case of using the WV-RC700A)
    3. Connect the 50-pin connector of the RCU cable to
    the  I/F REMOTE Connector of the camera.
    4. Turn RCU power on and the power indicator lamp
    will light.  The camera can now be remote con-
    trolled by the RCU.Notes:
    • The maximum extension distance between the
    camera and WV-RC700A is 300 m.  The maximum
    extension distance between the camera and WV-
    RC500 is 100 m.
    • Use the following options for cable extension.
    Studio Cable WV-CA26U15 (15 m/50 ft)
    WV-CA26U30 (30 m/100 ft)
    WV-CA26U100 (100 m/330 ft)
    Cable Joint Adaptor
    WV-CA26T26nCONNECTION OF A REMOTE CONTROL UNIT (RCU)
    Set to MULTIWV-RC700A
    RCU Cable
    AW-CA50A26 (15 m) 
    						
    							-16-
    VIDEO OUTG/L INI/F REMOTE OPTION CARDIRIS
    DC12V IN
    MENUITEM/AWCYES/ABCNO/BAR
    ALL 1
    2USER  SET
    ONPOWER
    OFFPOWERO    I
    FUSE(POWER)FUSEFUSE
    AC Adaptor  
    AW-PS505
    nCONNECTION OF A REMOTE CONTROL BOX (RCB)The RCB (WV-CB700A) and the camera must be con-
    nected with the optional RCB cable AW-CA50T10.
    1. Turn RCB power off before connecting cables.
    2. Connect the 50-pin connector of the RCB cable to
    I/F REMOTE connector of the camera.  The 10-pin
    connector must be connected to the RCB.
    3. Turn RCB power on and the camera can be con-
    trolled remotely by the RCB.
    Notes:
    • The monitor output signals of the RCB attenuate
    and deteriorate with cable length. It is recommend-
    ed that the signals from the monitor output be used
    for monitoring purposes only.
    • No gen-lock signal is available from the RCB.
    AC Adaptor
    AW-PS505
    Video signal IN
    RCB WV-CB700A
    1. Connect this to a DC 12 V class 2 power supply
    only.
    2. To prevent fire or shock, the UL listed wire VW-1,
    style 1007 should be used as for the cable for DC
    12 V Input Connector.Cautions
    RCB Cable AW-CA50T10 (3 m)
    MONITOR OUT
    DC Power Cable
    AW-CA4T1
    RCB 
    						
    							-17-
    • To connect the pan/tilt unit to the camera, use the
    pan/tilt unit cable AW-CA50T15.
    • Power is supplied from the pan/tilt unit.
    1.Before connecting them, press the power
    switch on the pan/tilt unit AC adaptor and the
    ON/OFF switch on the hybrid control panel in
    the OFF position, respectively.
    2.Fix the camera securely to the pan/tilt unit using
    the mounting adaptor.
    3.Connect the 50-pin end of the pan/tilt unit cable
    to the I/F Remote connector on the camera.
    Connect the 15-pin end of the cable to the
    pan/tilt unit.
    4.Connect the pan/tilt unit to the hybrid control
    panel with the 10BASE-T cable and coaxial
    cable.  For details, refer to the manual for the
    hybrid control panel.
    5.First switch on the pan/tilt unit AC adaptor, then
    press the ON/OFF switch on the hybrid control
    panel in the ON position.  The camera and pan/
    tilt unit can now be controlled from the hybrid
    control panel.nCONNECTION OF DEVICES WITH CAMERA PAN/TILT CONTROL SYSTEM
    TALLY DC12V IN
    AUX  CONTROL
    PREVIEW IN OUT 6/1  OUTBREVIEW MONITOR OUT
    CONTROL CONTROL  OUTPAN/TILT CAMERA
    TD  MULTI  PORT  HUBG / L  IN
    S-VIDEO OUT
    ONPOWER
    OFFPOWERO    I
    FUSE(POWER)FUSEFUSEFUSE(LAMP)FUSEFUSEAC AdaptorAW-PS300VIDEO OUTG/L INI/F REMOTE OPTION CARDIRIS
    DC12V IN
    MENUITEM/AWCYES/ABCNO/BAR
    PAN/TILT CONTROL
    CAMERA CONTROL 10BASE-T
    Cable
    Coaxial
    Cable
    Coaxial
    Cable VIDEOControl Panel
    AC Adaptor
    AW-PS301 Pan/tilt unit AC
    Adaptor AW-PS300
    Hybrid control
    panel
    AW-RP501Camera Mounting
    Hole Adaptor
    (Supplied)
    Pan/tilt unit Cable
    AW-CA50T15
    Composite Video
    S VIDEOVideo
    Monitor LENS
    ZOOM/FOCUS CableLENS
    IRIS Cable
    Pan/tilt unit
    AW-PH300 
    						
    							-18-
    nCONNECTION WITH MULTIPLE CAMERAS (COLOR LOCK MODE)lAn example of connection for VBS/BB input (Color lock
    mode).
    • One of the multiple cameras is used as the source of ref-
    erence signals.
    • Supply a synchronizing signal (BB) to the G/L Input
    Connectors of each cameras.• Do not switch off the camera used for supplying the
    reference signals.
    • Adjust the SC-phase and H-phase at the Video
    Output Connector.
    1
    2
    3
    1
    2
    3OUTPUT B OUTPUT A
    INPUT
    THR SEP
    75WHI-Z
    BA
    Convertible  Camera AW –
    E600
    Convertible  Camera AW –
    E600
    Convertible  Camera AW –
    E600
    VIDEO OUT CAMERA
    Camera for External Sync
    (or Special Effect Generator)G/L IN
    VIDEO OUT
    OUTPUT
    INPUT
    Video Output
    To Special Effect Generator or Monitoring SystemVideo
    Distributor
    WJ-300C External Sync
    Signal (BB) 
    						