Page 11
-9- 13. Cable Clamp Clamp the DC Power Supply Cable (AW-CA4T1) connected to the DC 12 V Input Connector to pre- vent it from slipping out. 14. G/L Input Connector (G/L IN) Signals synchronized with the reference signal are to be supplied to this connector when the camera is to be synchronized with the reference signal BB. 15. Optional Card Slot Slot for inserting an optional card. For details, refer to the manual for optional cards. 12. DC 12 V Input Connector (DC 12V IN) 12 V DC is supplied through the...
Page 12
-10- • Lenses of any make can be mounted on the cam- era as long as they are equipped with a 1/2” stan- dard bayonet. • Use the lens extension cable WV-CA12T12 (6”/ 15 cm) if your lens cable is too short. VIDEO OUTG/L INI/F REMOTE OPTION CARDIRIS DC12V IN MENUITEM/AWCYES/ABCNO/BAR Control Cable To Lens I/F Connector of Camera Pan/tilt Unit Camera Cable 1. Lens Mounting Rotate the lens fixing ring knob counterclockwise and remove the lens mount cap. Mount the lens on the camera and rotate the lens fixing...
Page 13
-11- 2. Fix the camera mounting base, pan/tilt unit, and tri- pod securely in the screw hole (1/4-20UNC) of the camera mounting adaptor. 3. If the camera cannot be securely fixed, stick the supplied rubber sheet to the mounting adaptor, then mount the camera. Mounting adaptor 2. Camera Mounting1. Fix the mounting adaptor to the top or bottom of the camera. Camera Mounting Bracket (WV-831)
Page 14
-12- 1. Fully open the iris by shooting a dark object. (Iris selection switch should be set to M.) 2. Loosen the flange back lock knob. 3. Aim the camera at any object over 2 meters away from the camera. 4. Set the lens to its TELE end first and adjust its focus with the focus ring. 5. Set the lens to its widest angle next and adjust its focus with the flange back adjust ring. 6. Adjust the focus ring and the flange back adjust ring alternately for the best focus within the zoom- ing range. Tighten the...
Page 15
-13- IRIS GAIN CONTROL IN A LENSAn iris gain control hole is usually provided in the front of the lens. Adjustment of the iris gain, with a screwdriv- er through the hole may be done as follows. (Shape and location of the hole may vary depending on the type of lens.) 1. Turn the iris selection switch to Position A (AUTO). 2. Rotate the iris gain control to the maximum gain, but in a range where no hunting or oscillating of the iris ring develops. Iris gain control (G, S) Automatic iris power zoom lens
Page 16
-14- Caution: The connection and installation should be done by qualified service personnel or system installers. Refer any servicing to qualified service personnel.CONNECTIONS VIDEO OUTG/L INI/F REMOTE OPTION CARDIRIS DC12V IN MENUITEM/AWCYES/ABCNO/BAR ONPOWER OFFPOWERO I FUSE(POWER) 125V 3.15AFUSEFUSE AC Adaptor AW-PS505 nCONNECTION OF DEVICE WITH A COMPOSITE INPUT CONNECTOR1. Connect this to a DC 12 V class 2 power supply only. 2. To prevent fire or shock, the UL listed wire VW-1, style 1007...
Page 17
-15- GEN-LOCK GEN-LOCKINAUX AUXINAUTO AUTO75¶/Hi-Z /Hi-ZAUTO AUTO75¶/Hi-Z /Hi-ZR/PR /C R/PR /C OUT OUTOUT OUT AUDIO AUDIOSEE MANUAL SEE MANUAL VIDEO 1 VIDEO 1 G/Y/Y G/Y/YVIDEO 2 VIDEO 2 B/PB /B B/PB /BSYNC SYNCS-VIDEO S-VIDEO 14 23TALLY TALLY CAMERA (MULTI) CAMERA (MULTI) CABLE SELECT CABLE SELECT FUSE FUSE250V 1.25A 250V 1.25A TALK TALK INCOM INCOM RECEIVE RECEIVECONTROL CONTROLTALLY & INCOM TALLY & INCOM MULTIOVP OVP MPX MPX MPX MPX OUTPUT OUTPUT VIDEO OUTG/L INI/F REMOTE OPTION CARDIRIS DC12V IN...
Page 18
-16- VIDEO OUTG/L INI/F REMOTE OPTION CARDIRIS DC12V IN MENUITEM/AWCYES/ABCNO/BAR ALL 1 2USER SET ONPOWER OFFPOWERO I FUSE(POWER)FUSEFUSE AC Adaptor AW-PS505 nCONNECTION OF A REMOTE CONTROL BOX (RCB)The RCB (WV-CB700A) and the camera must be con- nected with the optional RCB cable AW-CA50T10. 1. Turn RCB power off before connecting cables. 2. Connect the 50-pin connector of the RCB cable to I/F REMOTE connector of the camera. The 10-pin connector must be connected to the RCB. 3. Turn RCB power on...
Page 19
-17- • To connect the pan/tilt unit to the camera, use the pan/tilt unit cable AW-CA50T15. • Power is supplied from the pan/tilt unit. 1.Before connecting them, press the power switch on the pan/tilt unit AC adaptor and the ON/OFF switch on the hybrid control panel in the OFF position, respectively. 2.Fix the camera securely to the pan/tilt unit using the mounting adaptor. 3.Connect the 50-pin end of the pan/tilt unit cable to the I/F Remote connector on the camera. Connect the 15-pin end of the cable to...
Page 20
-18- nCONNECTION WITH MULTIPLE CAMERAS (COLOR LOCK MODE)lAn example of connection for VBS/BB input (Color lock mode). • One of the multiple cameras is used as the source of ref- erence signals. • Supply a synchronizing signal (BB) to the G/L Input Connectors of each cameras.• Do not switch off the camera used for supplying the reference signals. • Adjust the SC-phase and H-phase at the Video Output Connector. 1 2 3 1 2 3OUTPUT B OUTPUT A INPUT THR SEP 75WHI-Z BA Convertible Camera AW – E600 Convertible...