-9- 13. Cable Clamp Clamp the DC Power Supply Cable (AW-CA4T1) connected to the DC 12 V Input Connector to pre- vent it from slipping out. 14. G/L Input Connector (G/L IN) Signals synchronized with the reference signal are to be supplied to this connector when the camera is to be synchronized with the reference signal BB. 15. Optional Card Slot Slot for inserting an optional card. For details, refer to the manual for optional cards. 12. DC 12 V Input Connector (DC 12V IN) 12 V DC is supplied through the optional DC power supply cable (AW-CA4T1).
-10- • 1/3” C mount type lens can be mounted on the camera. • There may be a danger of damage to the camera depending on the type of lens. Use a lens whose mount screw height is 4.3 mm or less. – +MENU ITEM/AWC YES/ABC NO/BAROPTION CARD VIDEO OUT I/F REMOTE G/L IN IRIS DC12V IN Control Cable To Lens I/F Connector of Camera Pan/tilt Unit Camera Cable To Iris Connector 1. Lens Mounting Remove the body cap from the camera by pulling on it. Attach the lens into the lens mount and turn the lens clockwise to hold the lens securely. Connect the camera cable to the IRIS connector on the back panel of the camera. • Refer also to the manual for the lens because the mounting procedures may differ depending on the lens. 4.3 mm or less MOUNTING
-11- 2. Fix the camera mounting base, pan/tilt unit, and tri- pod securely in the screw hole (1/4-20UNC) of the camera mounting adaptor. 3. If the camera cannot be securely fixed, stick the supplied rubber sheet to the mounting adaptor, then mount the camera. Mounting adaptor 2. Camera Mounting1. Fix the mounting adaptor to the top or bottom of the camera. Camera Mounting Bracket (WV-831)
-12- 1. Fully open the iris by shooting a dark object. (Iris selection switch should be set to M.) 2. Remove the cap from the camera’s Flange-back Adjustment Screws. 3. Loosen the flange back lock screw. 4. Aim the camera at any object over 2 meters away from the camera. 5. Set the lens to its TELE end first and adjust its focus with the focus ring. 6. Set the lens to its widest angle next and adjust its focus with the focus screw. 7. Adjust the focus ring and the focus screw alternate- ly for the best focus within the zooming range. Tighten the lock screw upon completion of focus- ing. 8. Turn the iris selection switch to Position A. Convertible Camera AW – FOCUS LOCK 3.3 4 5 7 2 5.5 101.5 1.2 1 FOCUS Ring FOCUS ScrewLOCK Screw FLANGE BACK ADJUSTMENT
-13- IRIS GAIN CONTROL IN A LENSAn iris gain control hole is usually provided in the front of the lens. Adjustment of the iris gain, with a screwdriv- er through the hole may be done as follows. (Shape and location of the hole may vary depending on the type of lens.) 1. Turn the iris selection switch to Position A (AUTO). 2. Rotate the iris gain control to the maximum gain, but in a range where no hunting or oscillating of the iris ring develops. Iris gain control (G, S) Automatic iris power zoom lens
– +MENU ITEM/AWC YES/ABC NO/BAROPTION CARD VIDEO OUT I/F REMOTE G/L IN IRIS DC12V IN GEN-LOCK GEN-LOCKINAUX AUXINAUTO AUTO75 75¶/Hi-Z /Hi-ZAUTO AUTO75¶/Hi-Z /Hi-ZR/PR /C R/PR /C OUT OUTOUT OUT AUDIO AUDIOSEE MANUAL SEE MANUAL VIDEO 1 VIDEO 1 G/Y/Y G/Y/YVIDEO 2 VIDEO 2 B/PB /B B/PB /BSYNC SYNCS-VIDEO S-VIDEO 14 23TALLY TALLY CAMERA (MULTI) CAMERA (MULTI) CABLE SELECT CABLE SELECT FUSE FUSE250V 1.25A 250V 1.25A TALK TALK INCOM INCOM RECEIVE RECEIVECONTROL CONTROLTALLY & INCOM TALLY & INCOM MULTIOVP OVP MPX MPX MPX MPX OUTPUT OUTPUT -14- Caution: The connection and installation should be done by qualified service personnel or system installers. Refer any servicing to qualified service personnel. Connection to the RCU (WV-RC700A,WV-RC550) is made through the optional RCU cable AW-CA50A26. 1. Turn RCU power off before connecting cables. 2. Set the cable selection switch of the RCU to MULTI (in case of using the WV-RC700A) 3. Connect the 50-pin connector of the RCU cable to the I/F REMOTE Connector of the camera. 4. Turn RCU power on and the power indicator lamp will light. The camera can now be remote con- trolled by the RCU.Notes: • The maximum extension distance between the camera and WV-RC700A is 300 m. The maximum extension distance between the camera and WV- RC500 is 100 m. • Use the following options for cable extension. Studio Cable WV-CA26U15 (15 m/50 ft) WV-CA26U30 (30 m/100 ft) WV-CA26U100 (100 m/330 ft) Cable Joint Adaptor WV-CA26T26nCONNECTION OF A REMOTE CONTROL UNIT (RCU) Set to MULTIWV-RC700A RCU Cable AW-CA50A26 (15 m) CONNECTIONS
-15- – +MENU ITEM/AWC YES/ABC NO/BAROPTION CARD VIDEO OUT I/F REMOTE G/L IN IRIS DC12V IN ALL 1 2USER SET ONPOWER OFFPOWERO I FUSE(POWER) 125V 3.15AFUSEFUSE AC Adaptor AW-PS505 nCONNECTION OF A REMOTE CONTROL BOX (RCB)The RCB (WV-CB700A) and the camera must be con- nected with the optional RCB cable AW-CA50T10. 1. Turn RCB power off before connecting cables. 2. Connect the 50-pin connector of the RCB cable to I/F REMOTE connector of the camera. The 10-pin connector must be connected to the RCB. 3. Turn RCB power on and the camera can be con- trolled remotely by the RCB. Notes: • The monitor output signals of the RCB attenuate and deteriorate with cable length. It is recommend- ed that the signals from the monitor output be used for monitoring purposes only. • No gen-lock signal is available from the RCB. AC Adaptor AW-PS505 Video signal IN RCB WV-CB700A 1. Connect this to a DC 12 V class 2 power supply only. 2. To prevent fire or shock, the UL listed wire VW-1, style 1007 should be used as for the cable for DC 12 V Input Connector.Cautions RCB Cable AW-CA50T10 (3 m) MONITOR OUT DC Power Cable AW-CA4T1AC 120 V 50/60 HzRCB
– +MENU ITEM/AWC YES/ABC NO/BAROPTION CARD VIDEO OUT I/F REMOTE G/L IN IRIS DC12V IN ONPOWER OFFPOWERO I FUSE(POWER) 125V 3.15AFUSEFUSE AC Adaptor AW-PS505 -16- nCONNECTION OF DEVICE WITH A COMPOSITE INPUT CONNECTOR1. Connect this to a DC 12 V class 2 power supply only. 2. To prevent fire or shock, the UL listed wire VW-1, style 1007 should be used as for the cable for DC 12 V Input Connector.Cautions • Connection to any device which has a composite input connector, such as a video monitor or a VCR, must be made through the VIDEO OUT Connector. • Power supply to the camera must be through the optional DC power supply Cable AW-CA4TI. • For DC power supply, use the optional AC adaptor AW-PS505. VIDEO OUT Connector Video monitor AC Adaptor AW-PS505 VIDEO IN 75 ½coaxial cable DC Power supply Cable AW-CA4T1
-17- • To connect the pan/tilt unit to the camera, use the pan/tilt unit cable AW-CA50T15. • Power is supplied from the pan/tilt unit. 1.Before connecting them, press the power switch on the pan/tilt unit AC adaptor and the ON/OFF switch on the hybrid control panel in the OFF position, respectively. 2.Fix the camera securely to the pan/tilt unit using the mounting adaptor. 3.Connect the 50-pin end of the pan/tilt unit cable to the I/F Remote connector on the camera. Connect the 15-pin end of the cable to the pan/tilt unit. 4.Connect the pan/tilt unit to the hybrid control panel with the 10BASE-T cable and coaxial cable. For details, refer to the manual for the hybrid control panel. 5.First switch on the pan/tilt unit AC adaptor, then press the ON/OFF switch on the hybrid control panel in the ON position. The camera and pan/ tilt unit can now be controlled from the hybrid control panel.nCONNECTION OF DEVICES WITH CAMERA PAN/TILT CONTROL SYSTEM – +MENU ITEM/AWC YES/ABC NO/BAROPTION CARD VIDEO OUT I/F REMOTE G/L IN IRIS DC12V IN TA L LY DC12V IN AUX CONTROL PREVIEW IN OUT 6/1 OUTBREVIEW MONITOR OUT CONTROL CONTROL OUTPAN/TILT CAMERA TD MULTI PORT HUBG / L IN S-VIDEO OUT ONPOWER OFFPOWERO I FUSE(POWER) 250V T3.15AH 250V T3.15AHFUSEFUSEFUSE(LAMP)FUSEFUSEAC AdaptorAW-PS300 T T PAN/TILT CONTROL CAMERA CONTROL 10BASE-T Cable Coaxial Cable Coaxial CableVIDEOControl Panel AC Adaptor AW-PS301 AC 120 V 50/60 Hz Pan/tilt unit AC Adaptor AW-PS300AC 120 V 50/60 Hz Hybrid control panel AW-RP501Camera Mounting Hole Adaptor (Supplied) Pan/tilt unit Cable AW-CA50T15 Composite VideoS VIDEOVideo Monitor LENS ZOOM/FOCUS CableLENS IRIS Cable Pan/tilt unit AW-PH300
-18- nCONNECTION WITH MULTIPLE CAMERAS (COLOR LOCK MODE)lAn example of connection for VBS/BB input (Color lock mode). • One of the multiple cameras is used as the source of ref- erence signals. • Supply a synchronizing signal (BB) to the G/L Input Connectors of each cameras.• Do not switch off the camera used for supplying the reference signals. • Adjust the SC-phase and H-phase at the Video Output Connector. Convertible Camera AW – FOCUS LOCK Convertible Camera AW – FOCUS LOCK Convertible Camera AW – FOCUS LOCK 1 2 3 1 2 3OUTPUT B OUTPUT A INPUT THR SEP 75WHI-Z BA VIDEO OUT CAMERA Camera for External Sync (or Special Effect Generator)G/L IN VIDEO OUT OUTPUT INPUT Video Output To Special Effect Generator or Monitoring SystemVideo Distributor WJ-300C External Sync Signal (BB)