    Have a look at the manual Panasonic Color Cctv Camera Wv Cw864 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							32
    ● Alarm Input/Output (ALARM IN/OUT)
    Move the cursor to ALARM IN/OUT, and press the CAM (SET) key.
    The ALARM IN/OUT submenu appears.
    Note:While the camera is in the AF mode or the lens moves between
    WIDE and TELE, alarm input may be ignored if several alarm
    inputs are received in succession.
    ALARM IN 1-4
    Alarm input signals are supplied from external devices through
    the ALARM IN connector to turn the camera to a preset position.
    1. Move the cursor to ALARM IN 1* and select a preset position or
    OFF by moving the joystick, then press the CAM (SET) key.
    The factory default setting is OFF.
    *Set ALARM IN 2, 3 and 4 in the same way as ALARM IN 1.
    1 POSI, 2 POSI, 3 POSI and 4 POSI:Preset position. If an alarm
    input is received, the camera turns to a preset position, and
    sends an alarm output signal. The position number corre-
    sponds to the alarm input numbers (1-1, 2-2, 3-3 and 4-4).
    B/W:Available for ALARM INPUT 4 only. The camera changes its
    mode from color to black and white if ALARM IN 4 is sup-
    plied.
    OFF:The camera ignores alarm inputs.
    Note:If two or more alarm inputs are received while the camera is
    moving to a preset position, the camera starts to aim at preset
    positions in small preset numerical order after current posi-
    tioning.    ** SPECIAL 1 **
    PRIVACY ZONE
    PROPO.P/T
    AREA TITLE
    PATROL
    ALARM IN/OUT
    PASSWORD LOCK
    CLEANING
    EL-ZOOM
    PRESET ALM
    IMAGE HOLD     OFF
    RET          OFF(ENB) 
      ON
      ON(USER)
      STOP
       
      OFF  
      OFF 
      ON  
      OFF
    Special 1 menu
       ** ALARM IN/OUT **
    ALARM IN 1
    ALARM IN 2
    ALARM IN 3
    ALARM IN 4
     
    CNT-CLS 1
     TIME OUT
    CNT-CLS 2
    COAX ALM OUT
    RET         OFF 
     OFF 
     OFF
     OFF
       
     OFF  
     100MS 
     OFF  
     OFF
    ALARM I/O submenu
    CNT-CLS 1, 2 (Output)
    Two contact closure signals (Open collector type) are output through the Alarm Output connector.
    1. Move the cursor to CNT-CLS 1, and select OFF, ALARM or AUX 1 by moving the joystick to the right
    or left.
    The factory default setting is OFF.
    When ALARM is selected, TIME OUT appears. Select an appropriate duration from among 100 MS,
    200 MS, 1000 MS (1 s), 2000 MS (2 s) or 4000 MS (4 s) by moving the joystick to the right or left.
    The factory default setting is 100 MS.
    Note:The shorter the duration, the more frequent will be the detection output.
    2. Move the cursor to CNT-CLS 2, then select OFF, B/W or AUX 2 by moving the joystick to the right or
    left.
    The factory default setting is OFF.
    OFF:Contact closure signals are deactivated.
    ALM:Available for CNT-CLS 1 only. A motion detection signal is output.
    AUX 1(2):An alarm signal is output when the camera receives a command from the controller.
    B/W:Available for CNT-CLS 2 only. ON (active) is output when the camera operates in the black and
    white mode if ALARM IN 4 is set to B/W.
    Note:It is recommended to set the connected external device to ignore the shorter alarm outputs of
    90 ms or less from the camera. 
    						
    							33
          ** PASSWORD? **
       0 1 2 3 4 5 6 7 8 9
              . . .
              
    ↑
    OK  RESET
    NEW PASSWORD
    RET        
    PASSWORD
        ** SPECIAL 1 **
    PRIVACY ZONE   OFF(ENB)
    PROPO.P/T      ON
    AREA TITLE     ON(USER)
    PATROL         STOP
    ALARM IN/OUT
    PASSWORD LOCK  ON 
    CLEANING       OFF
    EL-ZOOM        ON
    PRESET ALM     OFF
    IMAGE HOLD     OFF
    RET
    Special 1 menu
    COAXIAL ALARM OUT
    Alarm output signals are supplied through the coaxial cable.
    1. Move the cursor to COAX ALM OUT and select ON or OFF.
    2. Press the CAM (SET) key.
    The factory default setting is OFF.
    ON:The camera sends an alarm output signal after it turns to a preset position.
    OFF:The camera does not send the output signal.
    Notes:
    •The camera ignores alarm inputs during manual operation.
    •Select OFF when the camera downloads or uploads the preset data.
    ●Password Lock (PASSWORD LOCK)
    Caution:For security do not operate your VCR for recording while the
    password menus are displayed on the monitor screen.
    A 3-digit number is used for a password to limit access to the privacy
    zone settings.
    1. Move the cursor to PASSWORD LOCK, then select ON or OFF by
    moving the joystick to the right or left.
    The factory default setting is OFF.
    Note:ON or OFF can be selected only after going through the
    password verification.
    OFF:Access to the privacy zone settings is free. ON(ENB) or
    OFF(ENB) for PRIVACY ZONE appears on the SPECIAL 1
    menu.
    ON:Access is limited in the verification menu. ON(DIS) or
    OFF(DIS) for PRIVACY ZONE appears on the SPECIAL 1
    menu.
    2. Press the CAM (SET) key.
    Password Verification
    3. The password verification menu appears.
    3-1 Select a numeral for the first digit by moving the joystick to
    the right or left, and press the CAM (SET) key. Though the
    entered password is not displayed, the up-arrow moves one
    character to the right.
    3-2 Repeat the above step for the 2nd and 3rd digits.
    Default: 123.
    3-3 The cursor moves to OK after all the three digits have been
    entered. Unless you want to change the password, press the
    CAM (SET) key.
    If the password entered is entered, the screen returns to SPE-
    CIAL 1. ON and OFF settings are the same as made on the
    SPECIAL 1 menu is as set in step 1.
    If a wrong password is entered, the screen returns to the veri-
    fication menu. Repeat steps 3-1 to 3-3 to verify the password.
    3-4 To cancel an incomplete password,. move the cursor to
    RESET, and press the CAM (SET) key. The screen returns to
    the verification menu. 
    						
    							34
    3-5 To return to the SPECIAL 1 menu without verifying the pass-
    word, move the cursor to RET, and press the CAM (SET) key.
    New Password
    4. To change the password in step 3-3 above, move the cursor from
    OK to NEW PASSWORD, and press the CAM (SET) key. The NEW
    PASSWORD menu appears.
    Notes:
    •The NEW PASSWORD menu is accessible only after the verifi-
    cation has been completed.
    •The following operations for NEW PASSWORD will not affect
    the ON/OFF setting for PRIVACY ZONE on the SPECIAL 1
    menu.
    The up-arrow mark appears indicating the first digit on the first
    line.
    4-1 Enter a new three-digit password in the same way as in steps
    3-1 to 3-2.
    4-2 The cursor moves to OK after all three digits have been
    entered. Press the CAM (SET) key to move the cursor to the
    first digit on the second line.
    4-3 Enter the same password as the one you have entered on the
    first line.
    4-4 The cursor moves to OK. Press the CAM (SET) key. If the new
    password is successfully entered, the screen returns to SPE-
    CIAL 1.
    4-5 Retry steps 4-1 to 4-4. If the first entry for the password is dif-
    ferent from the second one, the screen returns to the NEW
    PASSWORD? menu.
    4-6 To return to the SPECIAL 1 menu without changing the pass-
    word, move the cursor to RET, and press the CAM (SET) key.
    ●Cleaning (CLEANING)
    With CLEANING in the ON position, the camera’s built-in electro-
    mechanical contacts are cleaned at regular intervals (approx. every 7
    days).
    A dry contract adversely affects picture quality and motors operation.
    1. Move the cursor to CLEANING and select ON or OFF by moving
    the joystick to the right or left.
    The factory default setting is OFF.
    ON:The contacts are cleaned for approx. 1 minute. “CLEANING”
    disappears when over the cleaning process is completed.
    OFF:No contact cleaning.
    Note:Select OFF when the camera downloads or uploads the
    preset data.
       **  NEW PASSWORD? **
       
       0 1 2 3 4 5 6 7 8 9
              . . .
              
    ↑          . . .
             
    OK  RESET
    RET        
    NEW PASSWORD
        ** SPECIAL 1 **
    PRIVACY ZONE   OFF(ENB)
    PROPO.P/T      ON
    AREA TITLE     ON(USER)
    PATROL         STOP
    ALARM IN/OUT
    PASSWORD LOCK  OFF
    CLEANING       ON
    EL-ZOOM        ON
    PRESET ALM     OFF
    IMAGE HOLD     OFF
    RET
    Special 1 menu
    CLEANING
    CLEANING 
    						
    							35
    ●Electronic Zoom (EL-ZOOM)
    The electronic zoom magnifies a scene 10-fold. With a 22-fold optical
    zoom lens, the camera is capable of 220-fold zoom.
    1. Move the cursor to EL-ZOOM and select ON or OFF by moving
    the joystick to the right or left, and then press the CAM (SET) key.
    The factory default setting is ON.
    ON:10 - fold electronic zoom is available with the ZOOM switch
    on the controller.
    OFF:The electronic zoom function is not used.
    Notes:
    •A scene magnified by the electronic zoom function may be
    inferior in picture quality to a non-magnified one.
    •The electronic zoom does not function in the preset position
    setting mode.
    •To set preset positions directly from the WV-CU550B, WV-
    CU360 or WV-CU161 System Controller, you need to set the
    electronic zoom function temporarily to OFF.
    ●Preset Alarm (PRESET ALM)
    An alarm output is sent when the camera moves to the designated
    position depending on the mode.
    1. Move the cursor to PRESET ALARM and select ON or OFF.
    The factory default setting is OFF.
    ON:Alarm signals are output in the following cases.
    •When a preset positioning sequence is completed while
    AUTO MODE is set to SEQ.
    •When a preset positioning sequence is completed while
    AUTO MODE is set to SORT.
    •When positioning to the starting point is completed while
    AUTO MODE is set to AUTO PAN.
    •When the self-return function has returned the camera to its
    home position.
    •When preset positioning is completed by manual operation.
    •When positioning to the starting point is completed while
    PATROL is set to PLAY.
    OFF:Alarm signals are not output.
    Note:Select OFF when the camera downloads or uploads the
    preset data.
    ●Image Hold (IMAGE HOLD)
    The camera picture remains as a still image on the monitor screen
    until the camera reaches the preset position. This function is useful for
    surveillance via local area network.
    1. Move the cursor to IMAGE HOLD and select ON or OFF.
    The factory default setting is OFF.
        ** SPECIAL 1 **
    PRIVACY ZONE   OFF(ENB)
    PROPO.P/T      ON
    AREA TITLE     ON(USER)
    PATROL         STOP
    ALARM IN/OUT
    PASSWORD LOCK  OFF
    CLEANING       OFF
    EL-ZOOM        ON
    PRESET ALM     OFF
    IMAGE HOLD     OFF
    RET
    Special 1 menu
        ** SPECIAL 1 **
    PRIVACY ZONE   OFF(ENB)
    PROPO.P/T      ON
    AREA TITLE     ON(USER)
    PATROL         STOP
    ALARM IN/OUT
    PASSWORD LOCK  OFF
    CLEANING       OFF
    EL-ZOOM        ON
    PRESET ALM     ON
    IMAGE HOLD     OFF
    RET
    Special 1 menu
        ** SPECIAL 1 **
    PRIVACY ZONE   OFF(ENB)
    PROPO.P/T      ON
    AREA TITLE     ON(USER)
    PATROL         STOP
    ALARM IN/OUT
    PASSWORD LOCK  OFF
    CLEANING       OFF
    EL-ZOOM        ON
    PRESET ALM     OFF
    IMAGE HOLD     ON
    RET
    Special 1 menu 
    						
    							36
    ON:The last displayed still image is shown till the camera finishes
    moving to a preset position. However, the still image may be
    distorted with the effect of panning or tilting.
    OFF:The current image is being displayed while the camera is
    moving to a preset position.
    ■Camera Setting
    To Display the Camera Setting Menu
    •Move the cursor to CAMERA O, and press the CAM (SET) key.
    The camera setting menu appears.
    ●Camera Identification (CAMERA ID)
    1. Move the cursor to CAMERA ID, and select ON to display the
    camera identification by using the joystick.
    The factory default setting is OFF.
    2. Follow the steps below to edit the camera ID characters:
    2-1 Move the cursor to CAMERA ID and press the CAM (SET) key
    to display the character editing menu.
    2-2 Move the cursor to the character you want to edit or change
    by using the joystick, and press the CAM (SET) key. The
    selected character appears in the editing area.
    2-3 Repeat the steps above until all characters are edited.
    3. After editing the camera identification characters, follow the steps
    below to decide the position of the CAMERA ID.
    3-1 Move the cursor to POSI, and press the CAM (SET) key to
    display the ID position menu.
    3-2 Decide the position of the camera ID by using the joystick.
    Press the MON (ESC) key to fix the position, and return to the
    character editing menu.
    Notes:
    •When you want the pointer to move to a specific character in
    the editing area, select a new character, and press the CAM
    (SET) key. This function allows you to edit or correct a specif-
    ic character.
    •To enter a blank space into the camera ID, move the cursor to
    SPACE, and press the CAM (SET) key.
    •To erase all characters in the editing area, move the cursor to
    RESET, and press the CAM (SET) key.
       ** SET UP MENU **
    PRESET 1 
     MAP 
     HOME POSITION
     SELF RETURN
     AUTO MODE
     AUTO PAN KEY
     DIGITAL FLIP
     LOCAL/REMOTE
     SPECIAL1
    CAMERA
    RS485 SET UPOFF
    OFF
    OFF
    AUTO PAN
    ON
    LOCAL
    Setup menu
         ** SET UP **
    CAMERA ID
    ALC/MANUAL
    SHUTTER
    AGC
    SENS UP
    SYNC
    WHITE BAL
    MOTION DET
    AF MODE
    RET     SPECIAL2   ON 
    ALC 
    OFF
    ON(MID)
    X2 AUTO
    INT  
    ATW1 
    OFF 
    MANUAL S  
    Camera setting menu
    Character editing menu
    CAM1
         ** SET UP **
    CAMERA ID
    ALC/MANUAL
    SHUTTER
    AGC
    SENS UP
    SYNC
    WHITE BAL
    MOTION DET
    AF MODE
    RET     SPECIAL2    OFF 
     ALC 
     OFF
     ON(MID)
     X2 AUTO
     INT  
     ATW1 
     OFF  
     MANUAL S  
         CAMERA ID
         0123456789
         ABCDEFGHIJKLM
         NOPQRSTUVWXYZ
         ().,:;&#!?=
         +-*/%$
        SPACE
             POSI RET RESET
        CAM1............
         
    						
    							37
         CAMERA ID
         0123456789
         ABCDEFGHIJKLM
         NOPQRSTUVWXYZ
         ().,:;&#!?=
         +-*/%$
        SPACE
             POSI RET RESET
        CAM1............
        
         CAMERA ID
         0123456789
         ABCDEFGHIJKLM
         NOPQRSTUVWXYZ
         ().,:;&#!?=
         +-*/%$
        SPACE
             POSI RET RESET
        CAM1............
        
         ** SET UP **
    CAMERA ID
    ALC/MANUAL
    SHUTTER
    AGC
    SENS UP
    SYNC
    WHITE BAL
    MOTION DET
    AF MODE
    RET     SPECIAL2   OFF 
    ALC 
    OFF
    ON(MID)
    X2 AUTO
    INT  
    ATW1 
    OFF
    MANUAL S  
    Camera setting menu
        ** ALC CONT **
        BACK LIGHT COMP
    BLC
     
    LEVEL
    RETON
    ••••|••••
    -       +
        ** ALC CONT **
        BACK LIGHT COMP
    BLC
    MASK SET 
    LEVEL
    RETOFF
    ••••|••••
    -       +
    Backlight compensation menu
    •The CAMERA ID moves faster when the joystick is kept at the
    right or left for one second or more.
    •Move the cursor to RET to return to the SET UP menu, and
    press the CAM (SET) key.
    ●Light Control Setting (ALC/MANUAL)
    1. Display SET UP MENU on the monitor screen by referring to page
    16.
    2. Move the cursor to ALC/MANUAL and select ALC or MANUAL by
    using the joystick.
    The factory default setting is ALC.
    When you select ALC, set backlight compensation.
    Note:The backlight compensation submenu associated with this
    menu is described separately and should be set up after
    installing the camera at the site and observing the actual site
    picture.
    3. When MANUAL is selected, quit the setup menu by pressing the
    MON (ESC) key. Press the OPEN or CLOSE key on the controller
    for iris adjustment.
    (1) ALC Mode with BLC ON
    1. Press the CAM (SET) key after selecting ALC. The ALC CONT
    menu appears.
    2. Move the cursor to the BLC and select ON.
    3. If you want to adjust the video output level, move the “I” cursor for
    LEVEL. Adjust it to the desired level by using the joystick.
    4. Move the cursor to RET and press the CAM (SET) key to return to
    the CAM SET UP menu. To return to the camera picture, press the
    F4 button. 
    						
    							38
    (2) ALC Mode with BLC OFF
    1. Move the cursor to BLC and select OFF. (When you select MANU-
    AL, BLC is not available.) The MASK SET appears on the menu.
    2. Move the cursor to MASK SET and press the CAM (SET) key. The
    48 mask areas appear on the monitor screen. The cursor is blink-
    ing in the top left corner of the screen.
    3. To mask an area where backlight is bright, move the cursor to the
    area and press the CAM (SET) key. The mask turns white. Repeat
    this procedure to mask the desired area.
    4. To cancel a masked area, move the cursor to the area, and press
    the CAM (SET) key. To cancel all masking areas, press the F2
    button of the WV-CU550B. 
    For the WV-RM70, press the right and left switches simultaneous-
    ly.
    5. After masking is completed, press the MON (ESC) key. The 48
    mask areas on the monitor screen disappear and the ALC CONT
    menu appears.
    6. If you want to change the picture contrast, move the “I” cursor for
    LEVEL and adjust the level.
    7. Move the cursor to RET and press the CAM (SET) key to return to
    the CAM SET UP menu.
    To return to the camera picture, press the F4 button.Blinking
    Blinking
    Blinking
    Turns to white
        ** ALC CONT **
        BACK LIGHT COMP
    BLC
    MASK SET 
    LEVEL
    RETOFF
    ••••|••••
    -       +
        ** ALC CONT **
        BACK LIGHT COMP
    BLC
    MASK SET 
    LEVEL
    RETOFF
    ••••|••••
    -       + 
    						
    							39
    ●Shutter Speed Setting (SHUTTER)
    1. Display SET UP MENU on the monitor screen by referring to page
    16.
    2. Move the cursor to SHUTTER and select the electronic shutter
    speed by using the joystick. The factory default setting is OFF.
    The electronic shutter speed changes as follows by using the joy-
    stick:
    ●Gain Control (AGC)
    1. Display SET UP MENU on the monitor screen by referring to page
    16.
    2. Move the cursor to AGC and select ON (LOW), ON (MID), ON
    (HIGH) or (OFF) by using the joystick.
    The factory default setting is ON (MID).
    ON (LOW):Selects lower auto gain control.
    ON (MID):Selects normal auto gain control.
    ON (HIGH):Selects higher auto gain control.
    OFF (Fixed Level):Disables the gain control function.
    Notes:
    •Even if AGC is set to ON and if the noise reduction function is
    enabled, afterimages may be produced by shooting a moving
    object or by panning or tilting the camera.
    •For more information, refer to Digital Noise Reduction on page 46.
    ●Electronic Sensitivity Enhancement (SENS UP)
    1. Display SET UP MENU on the monitor screen by referring to page
    16.
    2. Move the cursor to SENS UP and select the desired electronic
    sensitivity enhancement mode by using the joystick.
    The factory default setting is X2 AUTO.
    The electronic sensitivity enhancement mode changes as follows
    by operating the joystick:
    Note:While the SENS UP function is selected, noise or spots may
    appear in the picture when the sensitivity of the camera is
    increased. This is a normal phenomenon.
    OFF (1/60)1/100
    1/10 0001/4 000 1/2 000 1/1 0001/2501/500
    X2 AUTOOFFX4 AUTOX6 AUTOX10 AUTO
    X16 AUTO
    X32 AUTOX2 FIX
    X6 FIXX10 FIXX16 FIX X32 FIX
    X4 FIXOFF
         ** SET UP **
    CAMERA ID
    ALC/MANUAL
    SHUTTER
    AGC
    SENS UP
    SYNC
    WHITE BAL
    MOTION DET
    AF MODE
    RET     SPECIAL2   OFF 
    ALC 
    OFF
    ON(MID)
    X2 AUTO
    INT  
    ATW1 
    OFF
    MANUAL S  
    Camera setting menu
         ** SET UP **
    CAMERA ID
    ALC/MANUAL
    SHUTTER
    AGC
    SENS UP
    SYNC
    WHITE BAL
    MOTION DET
    AF MODE
    RET     SPECIAL2   OFF 
    ALC 
    OFF
    ON(MID)
    X2 AUTO
    INT  
    ATW1 
    OFF
    MANUAL S 
    Camera setting menu
         ** SET UP **
    CAMERA ID
    ALC/MANUAL
    SHUTTER
    AGC
    SENS UP
    SYNC
    WHITE BAL
    MOTION DET
    AF MODE
    RET     SPECIAL2   OFF 
    ALC 
    OFF
    ON(MID)
    X2 AUTO
    INT  
    ATW1 
    OFF
    MANUAL S  
    Camera setting menu 
    						
    							40
    ●Synchronization (SYNC)
    1. Display SET UP MENU on the monitor screen by referring to page
    16.
    2. Move the cursor to SYNC and select LL or INT by using the joy-
    stick.
    The factory default setting is INT.
    Important Notices:
    1. The priority of SYNC modes is as follows:
    1. Multiplexed vertical drive (VD2) (highest priority)
    2. Line-lock (LL)
    3. Internal sync (INT) (lowest priority)
    2. To use internal sync, select INT.
    3. Whenever the vertical drive pulse (VD2) is supplied to the cam-
    era, the camera sync mode is automatically switched to the multi-
    plexed vertical drive pulse (VD2) regardless of the selected sync
    mode.
    Line-lock Sync Mode (LL)
    1. Display SET UP MENU on the monitor screen by referring to page
    16.
    2. Move the cursor to SYNC and select LL by using the joystick. LL
    sync mode is not available when the multiplexed vertical drive
    (VD2) pulse is supplied.
    3. After selecting LL, press the CAM (SET) key.
    The SYNC menu appears on the monitor screen.
    4. Supply the video output signal of the camera to be adjusted and
    the reference video output signal (for example, Camera 1) to a
    dual-trace oscilloscope.
    5. Set the dual-trace oscilloscope to the vertical rate and expand the
    vertical sync portion on the oscilloscope.
    6. Move the cursor to COARSE by using the joystick.
    7. Match the vertical phases for both video output signals as closely
    as possible by using the joystick. The coarse adjustment can be
    incremented in steps of 22.5 degrees (16 steps) with the joystick.
    Note:After the 16th step, the adjustment returns to the first step.
         ** SET UP **
    CAMERA ID
    ALC/MANUAL
    SHUTTER
    AGC
    SENS UP
    SYNC
    WHITE BAL
    MOTION DET
    AF MODE
    RET     SPECIAL2   OFF 
    ALC 
    OFF
    ON(MID)
    X2 AUTO
    INT  
    ATW1 
    OFF
    MANUAL S  
    Camera setting menu
         ** SET UP **
    CAMERA ID
    ALC/MANUAL
    SHUTTER
    AGC
    SENS UP
    SYNC
    WHITE BAL
    MOTION DET
    AF MODE
    RET     SPECIAL2   OFF
    ALC 
    OFF
    ON(MID)
    X2 AUTO
    LL  
    ATW1 
    OFF
    MANUAL S  
    Camera setting menu
          ** SYNC **
    V PHASE
    COARSE
    FINE
    RET1(1--16)
    •|•••••••
    -       +
    SYNC menu
    1 (1 - - - 16): 0 degrees
    2 (1 - - - 16): 22.5 degrees
    16 (1 - - - 16): 337.5 degrees
          ** SYNC **
    V PHASE
    COARSE
    FINE
    RET1(1--16)
    •|•••••••
    -       + 
    						
    							41
    8. Move the cursor to FINE by using the joystick.
    9. Match the vertical phase for both video output signals as closely
    as possible by using the joystick.
    Notes:
    •When the “|” cursor reaches the “+” end, it jumps back to “–”.
    At the same time, COARSE is incremented by one step to
    enable a continuous adjustment. The reverse takes place
    when the “|” cursor reaches the “–” end.
    •When the joystick is kept at the right or left for one second or
    more, the “|” cursor moves quickly.
    •To reset COARSE and FINE to the preset values, press the F2
    button of the WV-CU550B. For the WV-RM70, press the Right
    and Left switches simultaneously. COARSE is preset to zero-
    crossing of the AC line phase.
    •If the AC line phase contains spike noise, etc., the vertical
    phase of the video output signal may be disturbed.
    ●White Balance (WHITE BAL)
    (1) Auto-Tracing White Balance Mode (ATW1/ATW2)
    1. Display SET UP MENU on the monitor screen by referring to page
    16.
    2. Move the cursor to WHITE BAL and select ATW1 by using the joy-
    stick. 
    The factory default setting is ATW1.
    The white balance of the camera is automatically adjusted.
    3. For fine adjustment of ATW1/ATW2, press the CAM (SET) key. The
    ATW1/ATW2 fine adjustment menu appears on the monitor
    screen.
    4. Move the cursor to R.
    Obtain the optimum red gain by moving the joystick to the right or
    left.
    5. Move the cursor to B.
    Obtain the optimum blue gain by moving the joystick to the right
    or left.
    6. Move the cursor to RET by using the joystick and press the CAM
    (SET) key to return to the SET UP menu.
          ** SYNC **
    V PHASE
    COARSE
    FINE
    RET4(1--16)
    ••••••|••
    -       +
          ** SYNC **
    V PHASE
    COARSE
    FINE
    RET1(1--16)
    •|•••••••
    -       +
         ** SET UP **
    CAMERA ID
    ALC/MANUAL
    SHUTTER
    AGC
    SENS UP
    SYNC
    WHITE BAL
    MOTION DET
    AF MODE
    RET     SPECIAL2   OFF 
    ALC 
    OFF
    ON(MID)
    X2 AUTO
    INT  
    ATW1 
    OFF
    MANUAL S 
    Camera setting menu
          **  ATW1  **
    R
    B
    RET••••|••••
    -       +
    ••••|••••
    -       +
    ATW fine adjustment menu 
    						
    All Panasonic manuals Comments (0)