Page 41
5 Maintenance Screen of coaxial - LAN converter The maintenance screen can be displayed on the web browser of a PC connected to the network connector of a coaxial - LAN converter. Settings such as the following can be performed in the maintenance screen. – firmware version updates – Coaxial - LAN converter status confirmation – IP address changes IMPORTANT •To display the setting screen of a camera that is already mounted and connected, temporarily disconnect the ethernet cable from the camera side...
Page 42
5.1 Accessing the Maintenance Screen 5.1.1 Temporarily Changing the Computer’s IP Address Temporarily change the IP address assigned to your computer to access the coaxial - LAN converter’s maintenance screen. The procedure for changing the IP address differs depending on the operating system used. The following explains how to change the IP address of the PC in the Windows 7 system. In Microsoft ® Windows 7, this procedure must be performed by either the “Administrator” user, or a user assigned with...
Page 43
5.Select [Use the following IP address], then click [OK] after entering the IP address ( 192.168.249.*** ) and Subnet mask ( 255.255.255.0). Substitute “***” in “192.168.249.***” with any number between 1 and 254 other than 249 (this is the address assigned to the receiver side unit). • If an IP address has already been set, make a note of the current IP address and other settings so that you can return the computer to those settings after you have connected and configured the unit. 6. Click [Close] to...
Page 44
5.1.2 Accessing the Maintenance ScreenFollow the procedure below after you have changed the IP address of the computer. 1. Connect the camera side unit or the receiver side unit ( A) directly to a computer ( C ) using an ethernet cable ( B). When connecting the camera side unit to a PC, make sure it is connected to the receiver side unit with a coaxial cable, and that the receiver side unit is turned on. 2. Start the computer’s web browser. 3. Enter http://192.168.249.249/ in the web browser’s address...
Page 45
5.Click [OK]. • The maintenance screen is displayed. Receiver side unit Camera side unit IMPORTANT •Only a PC connected to the coaxial - LAN converter ’s network connector can display the maintenance screen and perform firmware updates, etc. • The maintenance screen is displayed in English. • The display differs between the receiver side and the camera side units. The upper picture shows the display screen of the receiver side unit. The “PLC link status ” and “MAC address of the Master ” are only...
Page 46
5.1.3 Maintenance Screen Overview Model number Name of current screen Click to jump to the corresponding page Click to restart the coaxial - LAN converter Click to view the copyright information Contents of the current screen Click to update the displayed information IMPORTANT• When consecutively connecting coaxial - LAN converters to the computer toaccess their maintenance screens, because the information (ARP table) of the previously connected coaxial LAN converter is retained, the maintenance screen...
Page 47
5.2 Using the Maintenance Screen 5.2.1 Confirming the coaxial - LAN converter’s Status You can confirm the information in the table below, such as the firmware version, MAC address of the coaxial - LAN converter, and the connection status of other coaxial - LAN converters on the [Status] screen. 1. Access the maintenance screen of the coaxial - LAN converter. 2. Click [Status]. The screen shown above is the maintenance screen of the receiver side unit. IMPORTANT • The screen shown here depicts the...
Page 48
ItemsDescriptionPLC link status (only displayed for the camera side unit)Displays the status of the connection between the camera side unit and receiver side unit. [Connected] is displayed when there is a connection, and [Disconnected] is displayed when there is no connection.MAC address of the Master (only displayed for the camera side unit)Displays the MAC address of the connected receiver side unit.48Operating Instructions 5 Maintenance Screen of coaxial - LAN converter
Page 49
5.2.2 Updating the coaxial - LAN converter’s FirmwareMake sure you download the latest version of the coaxial - LAN converter firmware from the Panasonic support site (http://security.panasonic.com/pss/security/support/) and save it to the computer before changing the computer's IP address and accessing the maintenance screen. 1. Access the maintenance screen of the coaxial - LAN converter. 2. Click [Upgrade]. 3.Click [Browse...], select the firmware file, then click [Open]. 4. Click [Start]. 5....
Page 50
5.2.3 Changing coaxial - LAN converter’s SettingsThe IP address for accessing the maintenance screen can be changed. The camera side and receiver side units can be connected at their default settings. Multiple units on the receiver side can also be connected at their default setting. Changing the coaxial - LAN converter’s IP address You may change the coaxial - LAN converter ’s IP address and subnet mask if necessary. Change the IP address in cases such as when the coaxial - LAN converter is using...