Have a look at the manual Panasonic Central Processing Unit Wj Mpu955 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
41 Other Functions Digital Output Function The following function is available only if Digital Outputs has been previously established through the Administration Console. 1. Select a Digital Output number by pressing the numer- ic keys. 2. Press the [DIGITAL OUT]key to produce a one shot pulse for activating an assigned event. Area Control Function The following function is available only if the monitors are previously assigned to the areas through the Administration Console. 1. Select an Area number by pressing the numeric keys. 2. Press the [AREA]key to apply all the controller’s func- tions to the selected area. Note:Pressing the [AREA]key with no numeric input will display currently selected area number on the LCD display. Joystick Calibration The following procedure is available at startup after the HELLO! display on the LCD display of the controller or after logging out. 1. Select [1][2][3][4][5]by pressing the numeric keys, then press the [F6]key. 2. Move the Joystick to the position specified by the LCD display prompts and hold it, then press the [CLEAR] key. Repeat this procedure. The prompts on the LCD display will be replaced by pressing the [CLEAR]key as shown below. Center (Press CLR) ↓ Up (Press CLR) ↓ Right (Press CLR) ↓ Down (Press CLR) ↓ Left (Press CLR) INFORMATIONEntry:105INFORMATIONDigOut105 LOGOUTAUX1 OFF AUX1 ON CALL PRESETPGM PRESET CAM POSIDIGITAL OUTDEF OFF DEF ON AREA AUX2 OFF AUX2 ON CAMERA (ENTER)AUTO PAN CAM ID VLD S T&D ALM SGEN SYS S ( ALARM) 0 8 7 MSTATUS VLD HALL ALM H BLK5 9 6 423 1 SHIFTCLEAR ( ESC) EXIT INFORMATIONEntry:2INFORMATIONArea 2 LOGOUTAUX1 OFF AUX1 ON CALL PRESETPGM PRESET CAM POSIDIGITAL OUTDEF OFF DEF ON AREA AUX2 OFF AUX2 ON CAMERA (ENTER)AUTO PAN CAM ID VLD S T&D ALM SGEN SYS S ( ALARM) 0 8 7 MSTATUS VLD HALL ALM H BLK5 9 6 423 1 SHIFTCLEAR ( ESC) EXIT INFORMATIONID: NO OPERATORINFORMATIONID:12345 UP DOWNR L ARMF.1F. 2F. 3CMENU OFFF. 4CMENU ONF. 5F. 6 CLOSEIRIS WIPEROPEN NEARFA R WIDETELE AUTO FOCUS ZOOM LOGOUTAUX1 OFF AUX1 ON CALL PRESETPGM PRESET CAM POSIDIGITAL OUT CAM ID VLD S T&D ALM SGEN SYS S ( ALARM) 0 8 7 DEF OFF DEF ON MSTATUS VLD HALL ALM H BLK5 9 6 423 1 SHIFTCLEAR ( ESC) EXIT AREA AUX2 OFF AUX2 ONDEFAULT FOCUS CAM FUNC CAMERA (ENTER)AUTO PAN
44 Before starting the following procedures, all system compo- nents must be turned on. The following procedures apply when the WV-CU360C System Controller is connected to the system. Log-in 1. Turn on the power switches of all system components. 2. Turn on the power of the WV-CU360C System Controller by connecting the AC adapter to the AC out- let. The LINK indicator lights up and NO USER will appear on the LED display of the system controller. 3. Select your registered operator ID number (up to 5 dig- its) by pressing the numeric buttons, then press the [CAMERA (ENTER)]button. The underline display now appears on the LED display of the controller.4. Select your registered Password (up to 5 digits) by pressing the numeric buttons, then press the [CAM- ERA (ENTER)]button. If operator ID and password are correct, READY will appear on the LED display. Note:If an operator ID and password error have occurred, the PROHIBITED indicator on the con- troller will light up and NO ACCESS will blink on the LED display for about 3 seconds. Then the Log-in procedure automatically returns to the start. Log-in and Log-out PROGRAM PRESET CALL PRESET AUX1 OFFALM S CAM IDT&D AUX1 ONVLD S GEN WIPERSYS S AUX2 OFFALM HAUX2 ONVDL H ALL SHIFT BLK EXIT CLEAR ( ESC)DEF OFF DEF ONCAMERA ( ENTER) AUTO PA N MON STATUS PROGRAM PRESET CALL PRESET AUX1 OFFALM S CAM IDT&D AUX1 ONVLD S GEN WIPERSYS S AUX2 OFFALM HAUX2 ONVDL H ALL SHIFT BLK EXIT CLEAR ( ESC)DEF OFF DEF ONCAMERA ( ENTER) AUTO PA N MON STATUS
45 IDs Display Function This controller has the following functions. Operator ID Display Pressing the [GROUP PRESET]button while holding down the [SHIFT]button will display the Operator ID on the LED display. Controller ID Display Pressing the [PREV]button while holding down the [SHIFT] button will display the Controller ID on the LED display. Log-out This function is used when an operator is leaving the con- troller, or no longer requires access to the system. 1. Hold down the [LOGOUT]button and then press the [CAMERA (ENTER)]button to log out. NO USER is displayed on the LED display of the con- troller. AUX1 OFFALM S CAM IDT&D AUX1 ONVLD S NEXTPREV S-CTL ID STOPPAUSE CAM MENU ON CAM MENU OFFTOUR SEQGROUP SEQ MONITOR LOCK OSD SERVICECAM FUNC OSD OPE ID GROUP PRESET LOG OUT F1 F2 GEN WIPERSYS S AUX2 OFFALM H MON STATUS AUX2 ONVDL H ALL SHIFT BLK EXIT CLEAR ( ESC)DEF OFF DEF ON AUX1 OFFALM S CAM IDT&D AUX1 ONVLD S NEXTPREV S-CTL ID STOPPAUSE CAM MENU ON CAM MENU OFFTOUR SEQGROUP SEQ MONITOR LOCK OSD SERVICECAM FUNC OSD OPE ID GROUP PRESET LOG OUT F1 F2 GEN WIPERSYS S AUX2 OFFALM H MON STATUS AUX2 ONVDL H ALL SHIFT BLK EXIT CLEAR ( ESC)DEF OFF DEF ON PROGRAM PRESET CALL PRESET AUX1 OFFALM S CAM IDT&D AUX1 ONVLD S GEN WIPERSYS S AUX2 OFFALM HAUX2 ONVDL H ALL SHIFT BLK EXIT CLEAR ( ESC)DEF OFF DEF ONCAMERA ( ENTER) AUTO PA N MON STATUS NEXTPREV S-CTL ID STOPPAUSE CAM MENU ON CAM MENU OFFTOUR SEQGROUP SEQ MONITOR LOCK OSD SERVICECAM FUNC OSD OPE ID GROUP PRESET LOG OUT F1 F2
46 Monitor and Camera Selection After log-in, the following operations are available for con- trolling the system. The operation begins with selecting a monitor; then select a camera to be displayed on the active monitor screen. Monitor Selection 1. Select the desired monitor number by pressing the numeric buttons, then press the [MONITOR]button to execute the selection. The MONITOR indicator on the controller is turned on and the selected monitor number is now displayed on the LED display of the controller. If the selected monitor number is not valid or parti- tioned, the PROHIBITED indicator is on and the number on the LED display will blink for about 3 seconds. Return to step 1 and select a new monitor number. 2. Pressing the [NEXT]button while holding down the [MONITOR]button will select the next higher monitor number, or pressing the [PREV]button while holding down the [MONITOR]button will select the next lower monitor number. Note:The BUSY indicator lights, if the monitor is select- ed by a higher priority operator. Control of the same monitor is denied to an operator with a lower priority. Camera Selection 1. Select the desired monitor. Refer to the Monitor Selection. 2. Select the desired camera number by pressing the numeric buttons, then press the [CAMERA (ENTER)] button. The selected camera picture appears on the currently selected monitor and the selected camera number is now displayed on the LED display of the controller. If the selected camera number is not valid or parti- tioned, the PROHIBITED indicator is on and the number on the LED display will blink for about 3 seconds. Return to step 2 and select a new camera number. 3. Pressing the [NEXT]button while holding down the [CAMERA (ENTER)]button will replace the currently selected camera with the next higher camera number, or pressing the [PREV]button while holding down the [CAMERA (ENTER)]button will replace the currently selected camera with the next lower camera number. Note:The BUSY indicator lights, if the camera is selected by a higher priority operator. Control of the same camera is denied to an operator with a lower priority. AUX1 OFFALM S CAM IDT&D AUX1 ONVLD S GEN WIPERSYS S AUX2 OFFALM HAUX2 ONVDL H ALL SHIFT BLK EXIT CLEAR ( ESC)DEF OFF DEF ON MON STATUS NEXTPREV S-CTL ID STOPPAUSE CAM MENU ON CAM MENU OFFTOUR SEQGROUP SEQ MONITOR LOCK OSD SERVICE OSD AUX1 OFFALM S CAM IDT&D AUX1 ONVLD S NEXTPREV S-CTL ID STOPPAUSE CAM MENU ON CAM MENU OFFTOUR SEQGROUP SEQ MONITOR LOCK OSD SERVICE OSD GEN WIPERSYS S AUX2 OFFALM H MON STATUS AUX2 ONVDL H ALL SHIFT BLK EXIT CLEAR ( ESC)DEF OFF DEF ON PROGRAM PRESET CALL PRESET AUX1 OFFALM S CAM IDT&D AUX1 ONVLD S GEN WIPERSYS S AUX2 OFFALM HAUX2 ONVDL H ALL SHIFT BLK EXIT CLEAR ( ESC)DEF OFF DEF ONCAMERA ( ENTER) AUTO PA N MON STATUS PROGRAM PRESET CALL PRESET AUX1 OFFALM S CAM IDT&D AUX1 ONVLD S GEN WIPERSYS S AUX2 OFFALM HAUX2 ONVDL H ALL SHIFT BLK EXITCLEAR ( ESC) DEF OFF DEF ONCAMERA ( ENTER) AUTO PA N MON STATUS NEXTPREV S-CTL ID STOPPAUSE CAM MENU ON CAM MENU OFFTOUR SEQGROUP SEQ MONITOR LOCK OSD SERVICE OSD
47 Priority Lock This function is used to retain control of a monitor for an operator, even after that operator has selected another monitor. Caution:This function will prevent operators with a lower priority from gaining control of a monitor. However, higher priority operators may still gain control of that monitor. Applying Priority Lock 1. Select the desired monitor to apply Priority Lock. Refer to the Monitor Selection. 2. Pressing the [MONITOR]button while holding down the [SHIFT]button will toggle the Priority Lock mode on and off on the active monitor. If the Priority Lock mode is selected, the monitor num- ber with L sign is displayed on the active monitor and the MONITOR LOCK indicator on the controller is on. Releasing Priority Lock 1. Select the desired monitor to release Priority Lock. Refer to the Monitor Selection. 2. Pressing the [MONITOR]button while holding down the [SHIFT]button will release the lock mode. The monitor number is displayed normally on the active monitor and the MONITOR LOCK indicator on the con- troller is now off. AUX1 OFFALM S CAM IDT&D AUX1 ONVLD S GEN WIPERSYS S AUX2 OFFALM HAUX2 ONVDL H ALL SHIFT BLK EXIT CLEAR ( ESC)DEF OFF DEF ON MON STATUS NEXTPREV S-CTL ID STOPPAUSE CAM MENU ON CAM MENU OFFTOUR SEQGROUP SEQ MONITOR LOCK OSD SERVICECAM FUNC OSD OPE ID GROUP PRESET LOG OUT F1 F2
48 Controlling Camera Site Accessories Controls for camera site accessories are located on the right side of the front panel of the System Controller. Included are Zoom Control, Focus Control, Iris Control, Preset and Pan/Tilt Controls. Normally, combination cam- eras equipped with the specific feature or a WV-RC100 or WV-RC150 Receiver are required to utilize these functions. Lens Control Note:Confirm that the specified lens, with power zoom/focus functions, is mounted on the camera. Also confirm that the Lens Selection (DC/VIDEO) on the camera is set to the DC position. Function capabilities vary between cameras. Referring to the operating instructions of each camera is recom- mended. 1. Select the desired monitor and camera. Refer to the Monitor Selection and Camera Selection. 2. Press the [FOCUS NEAR/FAR]buttons while observ- ing the monitor to adjust the lens focus to achieve a sharply focused picture. By pressing these buttons at the same time, the lens focus is set automatically, if the specified camera with the auto focus feature is used. 3. Press the [ZOOM TELE/WIDE]buttons while observing the monitor to adjust the lens zoom to achieve the desired picture. Press the [TELE]button to optically bring an object closer. Pressing the [WIDE]button has the reverse effect. 4. Press the [IRIS CLOSE/OPEN]buttons to close/open the lens iris. Adjust the lens iris by using these buttons to obtain the proper picture exposure. By pressing these buttons at the same time, the lens iris is reset to the factory default setting. Pan/Tilt Control Pan/Tilt Control (Manual Operation) 1. Select the desired monitor and camera. Refer to the Monitor Selection and Camera Selection. 2. Move the Joystick Controller to move the Pan/Tilt Head towards the desired direction. If the joystick is positioned in between UP and R, the Pan/Tilt Head moves diagonally towards Up and Right. Eight directions are available: Up / Down / Right / Left / Up-Right / Up-Left / Down-Right / Down-left. Pan/Tilt Control (Auto Panning) The following function requires the use of cameras equipped with this specific feature. 1. Select the desired monitor and camera. Refer to the Monitor Selection and Camera Selection. 2. Pressing the [CAMERA (ENTER)]button while holding down the [SHIFT]button will activate the Auto Panning function of the selected camera. 3. To cancel the auto panning function, move the Joystick Controller. FOCUS FA R NEAR AUTO FOCUS ZOOM TELE WIDE IRIS OPEN CLOSE AUTO IRIS PROGRAM PRESET CALL PRESET AUX1 OFFALM S CAM IDT&D AUX1 ONVLD S GEN WIPERSYS S AUX2 OFFALM HAUX2 ONVDL H ALL SHIFT BLK EXIT CLEAR ( ESC)DEF OFF DEF ONCAMERA ( ENTER) AUTO PA N MON STATUS UP DOWNR L
49 Pan/Tilt Control (Program Preset Position) The following function requires the use of cameras equipped with this specific feature. 1. Select the desired monitor and camera. Refer to the Monitor Selection and Camera Selection. 2. Move the camera to the position to be preset by mov- ing the Joystick Controller and pressing the lens control buttons. 3. Select the desired preset position number by pressing the numeric buttons. 4. Holding down the [PROGRAM PRESET]button, and then press the [CAMERA (ENTER)]button to save a preset position of the selected camera. Notes: •If the position number entered has been stored previously, the old position will be overwritten by the new one. •This function is disabled when the WV-CS600 Series or WV-CS650 Series Camera is connected to the Encoder. Pan/Tilt Control (Call Preset Position) The following function requires the use of cameras equipped with this specific feature. 1. Select the desired monitor and camera. Refer to the Monitor Selection and Camera Selection. 2. Select the preset position number by pressing the numeric buttons. 3. Press the [CALL PRESET]button to move to the pre- set position of the selected camera on the active moni- tor. Note:To be able to use the above function, the preset position number must have been set for that cam- era. PROGRAM PRESET CALL PRESET AUX1 OFFALM S CAM IDT&D AUX1 ONVLD S GEN WIPERSYS S AUX2 OFFALM HAUX2 ONVDL H ALL SHIFT BLK EXIT CLEAR ( ESC)DEF OFF DEF ONCAMERA ( ENTER) AUTO PA N MON STATUS PROGRAM PRESET CALL PRESET AUX1 OFFALM S CAM IDT&D AUX1 ONVLD S GEN WIPERSYS S AUX2 OFFALM HAUX2 ONVDL H ALL SHIFT BLK EXIT CLEAR ( ESC)DEF OFF DEF ONCAMERA ( ENTER) AUTO PA N MON STATUS
Auxiliary Control The following function is available only when the WV-RC100 or WV-RC150 Receivers are included in the system. 1. Select the desired monitor and camera. Refer to the Monitor Selection and Camera Selection. 2. Pressing the [2]button while holding down the [SHIFT] button will turn on the user’s auxiliary switch 1 of the Receiver. Pressing the [1]button holding down the [SHIFT]but- ton will turn off the user’s auxiliary switch 1 of the Receiver. 3. Press the [5]button while holding down the [SHIFT] button will turn on the user’s auxiliary switch 2 of the Receiver. Pressing the [4]button while holding down the [SHIFT] button will turn off the user’s auxiliary switch 2 of the Receiver. 50 Receiver Control Camera Housing Control The following function is available only when the WV-RC100 or WV-RC150 Receivers are included in the system and the specified camera housing is installed. • Wiper Control 1. Select the desired monitor and camera. Refer to the Monitor Selection and Camera Selection. 2. Pressing the [3]button while holding down the [SHIFT]button will turn on the Housing Wiper of the camera until buttons are released. • Defroster Control 1. Select the desired monitor and camera. Refer to the Monitor Selection and Camera Selection. 2. Pressing the [8]button while holding down the [SHIFT]button will turn on the housing defroster of the camera. To turn off the defroster, pressing the [7]button while holding down the [SHIFT]button. AUX1 OFFALM S CAM IDT&D AUX1 ONVLD S GEN WIPERSYS S AUX2 OFFALM HAUX2 ONVDL H ALL SHIFT BLK EXIT CLEAR ( ESC)DEF OFF DEF ON MON STATUS SHIFT BLK EXIT AUX1 OFFALM S CAM IDT&D AUX1 ONVLD S GEN WIPERSYS S AUX2 OFFALM HAUX2 ONVDL H ALL CLEAR ( ESC) DEF OFF DEF ON MON STATUS AUX1 OFFALM S CAM IDT&D AUX1 ONVLD S GEN WIPERSYS S AUX2 OFFALM HAUX2 ONVDL H ALL SHIFT BLK EXIT CLEAR ( ESC)DEF OFF DEF ON MON STATUS