Have a look at the manual Panasonic Central Processing Unit Wj Mpu955 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
31 Display Setting for Controller Adjustment of LCD Display The following procedures let you adjust backlight and con- trast of the controller’s LCD display. Back Light Adjustment Adjust the back light by turning the LCD BRIGHT control located on the rear of the controller. Clockwise:increases the back light brightness Counterclockwise:decreases the back light bright- ness Contrast Adjustment Adjust the contrast of the characters displayed on the LCD display by turning the LCD CONTRAST control located on the rear of the controller. Clockwise:increases the character contrast Counterclockwise:decreases the character contrast Adjustment of LED Display The following procedure lets you adjust the brightness of the Monitor and Camera LED displays and LED indicators on the controller. Adjust the brightness by turning the LED BRIGHT control located on the rear of the controller. Clockwise:increases brightness Counterclockwise:decreases brightness IDs Display Function This controller has the following functions. Operator ID Display Pressing the [GROUP PRESET]key while holding down the [SHIFT]key will display the Operator ID number on the LCD display. Controller ID Display Pressing the [PREV]key while holding down the [SHIFT] key will display the Controller ID number on the LCD dis- play. System Version Display Pressing the [NEXT]key while holding down the [SHIFT] key will display the system version number on the LCD dis- play. CONTRAST BRIGHT LCD BRIGHT LED INFORMATIONID:100 CAM ID VLD S T&D ALM SGEN SYS S ( ALARM) 0 8 7 MSTATUS VLD HALL ALM H BLK5 9 6 423 1 SHIFTCLEAR ( ESC) EXIT GROUP PRESETPREVS-CTL ID OPE IDNEXT GROUP SEQPAUSESTOP TOUR SEQREV RUNFWD RUN OSD VER MONITOR LOCK OSD SERVICE INFORMATIONSys Ctrl ID:1 CAM ID VLD S T&D ALM SGEN SYS S ( ALARM) 0 8 7 MSTATUS VLD HALL ALM H BLK5 9 6 423 1 SHIFTCLEAR ( ESC) EXIT GROUP PRESETPREVS-CTL ID OPE IDNEXT GROUP SEQPAUSESTOP TOUR SEQREV RUNFWD RUN OSD VER MONITOR LOCK OSD SERVICE INFORMATION Ver:3.0.0.1 CAM ID VLD S T&D ALM SGEN SYS S ( ALARM) 0 8 7 MSTATUS VLD HALL ALM H BLK5 9 6 423 1 SHIFTCLEAR ( ESC) EXIT GROUP PRESETPREVS-CTL ID OPE IDNEXT GROUP SEQPAUSESTOP TOUR SEQREV RUNFWD RUN OSD VER MONITOR LOCK OSD SERVICE
32 Controlling Camera Site Accessories Controls for camera site accessories are located on the right side of the front panel of the System Controller. Included are Zoom Control, Focus Control, Iris Control, Preset and Pan/Tilt Controls. Normally, combination cam- eras equipped with the specific feature or a WV-RC100 or WV-RC150 Receiver are required to utilize these functions. Lens Control Note:Confirm that the specified lens, with power zoom/focus functions, is mounted on the camera. Also confirm that the Lens Selection (DC/VIDEO) on the camera is set to the DC position. Function capabilities vary between cameras. Referring to the operating instructions of each camera is recom- mended. 1. Select the desired monitor and camera. Refer to the Monitor Selection and Camera Selection. 2. Press the [FOCUS NEAR/FAR]keys while observing the monitor to adjust the lens focus to achieve a sharply focused picture. By pressing these keys at the same time, the lens focus is set automatically, if the specified camera with the auto focus feature is used. 3. Press the [ZOOM TELE/WIDE]keys while observing the monitor to adjust the lens zoom to achieve the desired picture. Press the [TELE]key to optically bring an object clos- er. Pressing the [WIDE]key has the reverse effect. 4. Press the [IRIS CLOSE/OPEN]keys to close/open the lens iris. Adjust the lens iris by using these keys to obtain the proper picture exposure.By pressing these keys at the same time, the lens iris is reset to the factory default setting. Pan/Tilt Control Pan/Tilt Control (Manual Operation) 1. Select the desired monitor and camera. Refer to the Monitor Selection and Camera Selection. 2. Move the Joystick Controller to move the Pan/Tilt Head towards the desired direction. If the joystick is positioned in between UP and R, the Pan/Tilt Head moves diagonally towards Up and Right. Eight directions are available: Up / Down / Right / Left / Up-Right / Up-Left / Down-Right / Down-left. Pan/Tilt Control (Auto Panning) The following function requires the use of cameras equipped with this specific feature. 1. Select the desired monitor and camera. Refer to the Monitor Selection and Camera Selection. 2. Pressing the [CAMERA (ENTER)]key while holding down the [SHIFT]key will activate the Auto Panning function of the selected camera. 3. To cancel the auto panning function, move the Joystick Controller. NEARFA R AUTO FOCUSFOCUS WIDETELE ZOOM CLOSE WIPER OPEN DEFAULTIRIS UP DOWNR L LOGOUTAUX1 OFF AUX1 ON CALL PRESETPGM PRESET CAM POSIDIGITAL OUTDEF OFF DEF ON AREA AUX2 OFF AUX2 ON CAMERA (ENTER)AU TO PAN CAM ID VLD S T&D ALM SGEN SYS S ( ALARM) 0 8 7 MSTATUS VLD HALL ALM H BLK5 9 6 423 1 SHIFTCLEAR ( ESC) EXIT
33 Pan/Tilt Control (Program Preset Position) The following function requires the use of cameras equipped with this specific feature. 1. Select the desired monitor and camera. Refer to the Monitor Selection and Camera Selection. 2. Move the camera to the position to be preset by mov- ing the Joystick Controller and pressing the lens control keys. 3. Select the desired preset position number by pressing the numeric keys. 4. Holding down the [PGM PRESET]key, and then press the [CAMERA (ENTER)]key to save a preset position of the camera. Notes: •If the position number entered has been stored previously, the old position will be overwritten by the new one. •This function is disabled when the WV-CS600 Series or WV-CS650 Series Camera is connected to the Encoder. Pan/Tilt Control (Call Preset Position) The following function requires the use of cameras equipped with this specific feature. 1. Select the desired monitor and camera. Refer to the Monitor Selection and Camera Selection. 2. Select the preset position number by pressing the numeric keys.3. Press the [CALL PRESET]key to move to the preset position of the selected camera on the active monitor. Note:To be able to use the above function, the preset position number must have been set for that cam- era. INFORMATIONEntry:48INFORMATIONPrg Preset48 LOGOUTAUX1 OFF AUX1 ON CALL PRESETPGM PRESET CAM POSIDIGITAL OUTDEF OFF DEF ON AREA AUX2 OFF AUX2 ON CAMERA (ENTER)AUTO PAN CAM ID VLD S T&D ALM SGEN SYS S ( ALARM) 0 8 7 MSTATUS VLD HALL ALM H BLK5 9 6 423 1 SHIFTCLEAR ( ESC) EXIT INFORMATIONEntry:52INFORMATIONPreset 52 LOGOUTAUX1 OFF AUX1 ON CALL PRESETPGM PRESET CAM POSIDIGITAL OUTDEF OFF DEF ON AREA AUX2 OFF AUX2 ON CAMERA (ENTER)AUTO PAN CAM ID VLD S T&D ALM SGEN SYS S ( ALARM) 0 8 7 MSTATUS VLD HALL ALM H BLK5 9 6 423 1 SHIFTCLEAR ( ESC) EXIT
34 Receiver Control Camera Housing Control The following function is available only when the WV-RC100 or WV-RC150 Receivers are included in the system and the specified camera housing is installed. • Wiper Control 1. Select the desired monitor and camera. Refer to the Monitor Selection and Camera Selection. 2. Pressing the [IRIS CLOSE]key while holding down the [SHIFT]key will turn on the Housing Wiper of the camera until the keys are released. • Defroster Control 1. Select the desired monitor and camera. Refer to the Monitor Selection and Camera Selection. 2. Pressing the [DIGITAL OUT]key while holding down the [SHIFT]key will turn on the housing defroster of the camera. To turn off the defroster, pressing the [CAM POSI] key while holding down the [SHIFT]key. Auxiliary Control The following function is available only when the WV-RC100 or WV-RC150 Receivers are included in the system. 1. Select the desired monitor and camera. Refer to the Monitor Selection and Camera Selection. 2. Pressing the [AREA]key while holding down the [SHIFT]key will turn on the user’s auxiliary switch 1 of the Receiver. Pressing the [LOG OUT]key holding down the [SHIFT] key will turn off the user’s auxiliary switch 1 of the Receiver. 3. Press the [PGM PRESET]key while holding down the [SHIFT]key will turn on the user’s auxiliary switch 2 of the Receiver. Pressing the [CALL PRESET]key while holding down the [SHIFT]key will turn off the user’s auxiliary switch 2 of the Receiver. INFORMATIONWiper On CAM ID VLD S T&D ALM SGEN SYS S ( ALARM) 0 8 7 MSTATUS VLD HALL ALM H BLK5 9 6 423 1 SHIFTCLEAR ( ESC) EXIT LOGOUTAUX1 OFF AUX1 ON CALL PRESETPGM PRESET CAM POSIDIGITAL OUT CAMERA (ENTER) DEF OFF AUTO PANDEF ON AREA AUX2 OFF AUX2 ON CLOSEIRIS WIPEROPEN NEARFA R WIDETELE AUTO FOCUS ZOOM DEFAULT FOCUS INFORMATIONDef On LOGOUTAUX1 OFF AUX1 ON CALL PRESETPGM PRESET CAM POSIDIGITAL OUTDEF OFF DEF ON AREA AUX2 OFF AUX2 ON CAMERA (ENTER)AUTO PAN CAM ID VLD S T&D ALM SGEN SYS S ( ALARM) 0 8 7 MSTATUS VLD HALL ALM H BLK5 9 6 423 1 SHIFTCLEAR ( ESC) EXIT INFORMATIONAux1 On LOGOUTAUX1 OFF AUX1 ON CALL PRESETPGM PRESET CAM POSIDIGITAL OUTDEF OFF DEF ON AREA AUX2 OFF AUX2 ON CAMERA (ENTER)AUTO PAN CAM ID VLD S T&D ALM SGEN SYS S ( ALARM) 0 8 7 MSTATUS VLD HALL ALM H BLK5 9 6 423 1 SHIFTCLEAR ( ESC) EXIT
35 Camera Function Control Camera Setup The following function requires the use of cameras equipped with this specific feature. 1. Select the desired monitor and camera. Refer to the Monitor Selection and Camera Selection. 2. Pressing the [F4]key while holding down the [SHIFT] key will gain access to the Camera Setup Menu display on the active monitor. 3. Select the desired item in the menu by moving the Joystick Controller UPand DOWN, and then select the desired parameter (or mode) in the menu by moving the Joystick Controller Land R. Press the [CAMERA (ENTER)]key to execute the cur- rently highlighted selection and to enter a submenu of the Camera Setup Menu, or press the [CLEAR (ESC)] key to leave the currently selected menu and return to the previous page of the menu. 4. Press the [RESET]key in the menu to reset the para- meter of a selected item to the factory default setting or enter the Special Camera Menu when the cursor is positioned on SPECIAL in the menu. Pressing the [RESET]key while holding down the [SHIFT]key will restore all factory default settings. Notes: •Refer to the Operating Instructions of the selected camera for more details. •Moving the joystick while holding down the [SHIFT] key will move the camera smoothly for presetting the position in the camera setup menu. 5. To close the Camera Setup Menu, press the [F3]key while holding down the [SHIFT]key. Changing to Black and White Pictures The following function is available only when specified cam- eras having a color-black and white switching feature are used. 1. Select the desired monitor and camera. Refer to the Monitor Selection and Camera Selection. 2. Press the [F6]key two times. B/W Change as shown in the figure will appear on the LCD display of the controller. 3. Press the [1]key to change the picture from color to black and white on the active monitor. 4. Press the [2]key to change black and white to color picture on the active monitor. 5. To exit from the mode, press the [CLEAR (ESC)]key. Note:When the black and white parameter is set AUTO in the camera setup menu, this function is disabled. INFORMATIONCam Menu On ALARMACKRESETALL RESETARM GROUP PRESETPREVS-CTL ID OPE IDNEXT GROUP SEQPAUSESTOP TOUR SEQREV RUNFWD RUN OSD F.1F. 2F. 3CMENU OFFF. 4CMENU ONF. 5F. 6 CLOSEIRIS WIPEROPEN NEARFA R WIDETELE AUTO FOCUS ZOOM MONITOR LOCK OSD SERVICE LOGOUTAUX1 OFF AUX1 ON CALL PRESETPGM PRESET CAM POSIDIGITAL OUT CAM ID VLD S T&D ALM SGEN SYS S ( ALARM) 0 8 7 DEF OFF DEF ON MSTATUS VLD HALL ALM H BLK5 9 6 423 1 SHIFTCLEAR ( ESC) EXIT AREA AUX2 OFF AUX2 ONDEFAULT FOCUS VERCAM FUNC CAMERA (ENTER)AUTO PAN INFORMATION B/W change 1:On 2:Off ARMF.1F. 2F. 3CMENU OFFF. 4CMENU ONF. 5F. 6 CLOSEIRIS WIPEROPEN NEARFA R WIDETELE AUTO FOCUS ZOOM LOGOUTAUX1 OFF AUX1 ON CALL PRESETPGM PRESET CAM POSIDIGITAL OUT CAM ID VLD S T&D ALM SGEN SYS S ( ALARM) 0 8 7 DEF OFF DEF ON MSTATUS VLD HALL ALM H BLK5 9 6 423 1 SHIFTCLEAR ( ESC) EXIT AREA AUX2 OFF AUX2 ONDEFAULT FOCUS CAM FUNC CAMERA (ENTER)AUTO PAN
36 Patrol Learn and Play The following function requires the use of cameras equipped with this specific feature. A routine of manual operations can be stored for a specific time and later reproduced repetitively. 1. Select the desired monitor and camera. Refer to the Monitor Selection and Camera Selection. 2. Press the [F6]key three times. Patrol Learn as shown in the figure will appear on the LCD display of the controller. To save the patrol sequence, follow the procedure shown below. qPress the [2]key, then press the [CAMERA (ENTER)]key to start Patrol Learn. wOperate the camera manually. Operations data (patrol sequence) is stored. ePress the [3]key to end the learning. To reproduce the stored data, follow the procedure shown below. qPress the [1]key to reproduce the stored Patrol function. wPress the [3]key to end the reproduction. 3. To exit from the mode, press the [CLEAR (ESC)]key. Camera Panning Function The following function requires the use of cameras equipped with this specific feature. 1. Select the desired monitor and camera. Refer to the Monitor Selection and Camera Selection. 2. Press the [F6]key four times. Pan Action as shown in the figure will appear on the LCD display of the controller. 3. Press the assigned numeric key shown below to acti- vate the panning function of the selected camera. 1:Activates Auto Pan. 2:Activates Sort Pan. 3:Activates Sequence Pan. 4:Activates Random Pan. Notes: •The AUTO MODE parameter previously set in the camera setup menu will be automatically replaced to the activated function parameter. •Random Pan function is not currently supported. 4. To exit from the mode, press the [CLEAR (ESC)]key. INFORMATION Patrol Learn 1:Play 2:Learn(2+Enter) 3:Stop ARMF.1F. 2F. 3CMENU OFFF. 4CMENU ONF. 5F. 6 CLOSEIRIS WIPEROPEN NEARFA R WIDETELE AUTO FOCUS ZOOM LOGOUTAUX1 OFF AUX1 ON CALL PRESETPGM PRESET CAM POSIDIGITAL OUT CAM ID VLD S T&D ALM SGEN SYS S ( ALARM) 0 8 7 DEF OFF DEF ON MSTATUS VLD HALL ALM H BLK5 9 6 423 1 SHIFTCLEAR ( ESC) EXIT AREA AUX2 OFF AUX2 ONDEFAULT FOCUS CAM FUNC CAMERA (ENTER)AUTO PAN INFORMATION Pan Action 1:Pan 3:seq 2:Sort 4:Random ARMF.1F. 2F. 3CMENU OFFF. 4CMENU ONF. 5F. 6 CLOSEIRIS WIPEROPEN NEARFA R WIDETELE AUTO FOCUS ZOOM LOGOUTAUX1 OFF AUX1 ON CALL PRESETPGM PRESET CAM POSIDIGITAL OUT CAM ID VLD S T&D ALM SGEN SYS S ( ALARM) 0 8 7 DEF OFF DEF ON MSTATUS VLD HALL ALM H BLK5 9 6 423 1 SHIFTCLEAR ( ESC) EXIT AREA AUX2 OFF AUX2 ONDEFAULT FOCUS CAM FUNC CAMERA (ENTER)AU TO PAN
37 Running Sequence Tour Sequence The following functions are available only if a Tour Sequence has been previously established through the Administration Console. As described on the setup, any of the tours can be assigned to any of the monitors. 1. Select the desired monitor. Refer to the Monitor Selection. 2. Select the desired Tour Sequence Number by pressing the numeric keys. 3. Pressing the [FWD RUN]key while holding down the [TOUR SEQ]key will run the tour sequence in forward direction on the active monitor, or pressing the [REV RUN]key while holding down the [TOUR SEQ]key will run the tour sequence in reverse direction on the active monitor. The selected Tour Sequence Number (T8) with R sign (indicate running status) is displayed on the active monitor. Note:By the factory default setting, pressing the [TOUR SEQ]key after numeric input will run the selected Tour Sequence forward. 4. Press the [PAUSE]key to pause a Tour Sequence that is being run on the active monitor. The P sign (indicating the pause status) is displayed at the Tour Sequence Number on the active monitor. 5. Press the [FWD RUN]key to restart a Tour Sequence forward from the next step that was previously paused by pressing the PAUSE key. 6. Press the [REV RUN]key to restart a Tour Sequence backward from the next step that was previously paused by pressing the PAUSE key.7. Press the [NEXT]key to move the sequence one frame to the next step (in forward or reverse run direction) from the step that was previously paused by pressing the PAUSE key. 8. Press the [PREV]key to move the sequence one frame to the previous step (in forward or reverse run direc- tion) from the step that was previously paused by pressing the PAUSE key. 9. To return to Spot monitoring, press the [STOP]key to end a Tour Sequence that is being run on the active monitor. INFORMATIONEntry:8INFORMATIONSeq 8 Fwd Run CAM ID VLD S T&D ALM SGEN SYS S ( ALARM) 0 8 7 MSTATUS VLD HALL ALM H BLK5 9 6 423 1 SHIFTCLEAR ( ESC) EXIT GROUP PRESETPREVS-CTL ID OPE IDNEXT GROUP SEQPAUSESTOP TOUR SEQREV RUNFWD RUN OSD VER MONITOR LOCK OSD SERVICE INFORMATIONSeq 8 Pause
38 On-Screen Display Control The procedure described below lets you determine the dis- play, such as camera title, clock and status, on and off on the active monitor screen. Note:The following functions are not available when the on-screen displays are compounded from the Character Board that is installed on the Camera Input Board. Confirm the setting in the Administration Console for details. 1. Select the desired monitor. Refer to the Monitor Selection. 2. Pressing the [1]key while holding down the [OSD]key will toggle the clock (time and date) display on the active monitor on and off.3. Pressing the [2]key while holding down the [OSD]key will toggle the camera number and title display on the active monitor on and off. 4. Pressing the [3]key while holding down the [OSD]key will toggle the general status display on the active mon- itor on and off. Monitor Display Control 07/07/1999 03:37:21 PM M AREA1 ALM T R A C CAMERA TITLE CAM ID VLD S T&D ALM SGEN SYS S ( ALARM) 0 8 7 MSTATUS VLD HALL ALM H BLK5 9 6 423 1 SHIFTCLEAR ( ESC) EXIT GROUP PRESETPREVS-CTL ID OPE IDNEXT GROUP SEQPAUSESTOP TOUR SEQREV RUNFWD RUN OSD VER MONITOR LOCK OSD SERVICE 07/07/1999 03:37:21 PM M AREA1 ALM T R A C CAMERA TITLE CAM ID VLD S T&D ALM SGEN SYS S ( ALARM) 0 8 7 MSTATUS VLD HALL ALM H BLK5 9 6 423 1 SHIFTCLEAR ( ESC) EXIT GROUP PRESETPREVS-CTL ID OPE IDNEXT GROUP SEQPAUSESTOP TOUR SEQREV RUNFWD RUN OSD VER MONITOR LOCK OSD SERVICE 07/07/1999 03:37:21 PM M AREA1 ALM T R A C CAMERA TITLE CAM ID VLD S T&D ALM SGEN SYS S ( ALARM) 0 8 7 MSTATUS VLD HALL ALM H BLK5 9 6 423 1 SHIFTCLEAR ( ESC) EXIT GROUP PRESETPREVS-CTL ID OPE IDNEXT GROUP SEQPAUSESTOP TOUR SEQREV RUNFWD RUN OSD VER MONITOR LOCK OSD SERVICE
39 5. Pressing the [5]key while holding down the [OSD]key will toggle the monitor status display on the active mon- itor on and off. 6. Pressing the [6]key while holding down the [OSD]key will toggle the display except clock (time and date) on the active monitor on and off. 07/07/1999 03:37:21 PM M AREA1 ALM T R A C CAMERA TITLE CAM ID VLD S T&D ALM SGEN SYS S ( ALARM) 0 8 7 MSTATUS VLD HALL ALM H BLK5 9 6 423 1 SHIFTCLEAR ( ESC) EXIT GROUP PRESETPREVS-CTL ID OPE IDNEXT GROUP SEQPAUSESTOP TOUR SEQREV RUNFWD RUN OSD VER MONITOR LOCK OSD SERVICE 07/07/1999 03:37:21 PM M AREA1 ALM T R A C CAMERA TITLE CAM ID VLD S T&D ALM SGEN SYS S ( ALARM) 0 8 7 MSTATUS VLD HALL ALM H BLK5 9 6 423 1 SHIFTCLEAR ( ESC) EXIT GROUP PRESETPREVS-CTL ID OPE IDNEXT GROUP SEQPAUSESTOP TOUR SEQREV RUNFWD RUN OSD VER MONITOR LOCK OSD SERVICE
40 Alarm Control When cameras and monitor are armed for alarm response with an alarm input, the camera pictures associated with that alarm input is displayed on the monitor when the alarm is received. When an alarm is received, the ALARM indicator lights. The indicator remains lit until all alarms are cleared by pressing the RESET key. Alarm Arming Control 1. Select an alarm number by pressing the numeric keys, followed by the [ALARM]key. 2. Pressing the [ARM]key repeatedly will arm or disarm cameras and monitor for alarm response with the selected alarm. Armed or Disarmed will be displayed on the LCD display. 3. Pressing the [NEXT]key while holding down the [ALARM]key will select the next higher alarm number, or pressing the [PREV]key while holding down the [ALARM]key will select the next lower alarm number. 4. Pressing the [ARM]key repeatedly will arm or disarm cameras and monitor for alarm response with the selected alarm. 5. To exit from alarm selecting mode, press the [CLEAR (ESC)]key. To Cancel Alarms 1. Select an activated alarm number that is displayed on the active monitor by pressing the numeric keys, fol- lowed by the [ALARM]key. 2. Select the alarm action number by pressing the numer- ic key, then press the [ACK]key to acknowledge the activated alarm manually. The acknowledged alarm picture is displayed on the active monitor, and the ACK indicator on the controller is turned on. Note:By the factory default setting, pressing only the [ACK] key will interpret it as the alarm action #0. 3. After acknowledging the alarm, press the [RESET]key to reset the alarm. The ACK indicator will go off. Note:All reset function is available without selecting the activated alarms. Pressing the [RESET]key while holding down the [SHIFT]key will cancel all currently activated alarms at once. INFORMATIONEntry:43INFORMATIONAlarm 43 Armed ALARMACKRESETALL RESETARMF.1F. 2 CAM ID VLD S T&D ALM SGEN SYS S ( ALARM) 0 8 7 MSTATUS VLD HALL ALM H BLK5 9 6 423 1 SHIFTCLEAR ( ESC) EXIT GROUP PRESETPREVS-CTL ID OPE IDNEXT GROUP SEQPAUSESTOP TOUR SEQREV RUNFWD RUN OSD VER MONITOR LOCK OSD SERVICE INFORMATIONAlarm 43INFORMATIONAlarm 43 Acknowledged ALARMACKRESETALL RESETARMF.1F. 2 CAM ID VLD S T&D ALM SGEN SYS S ( ALARM) 0 8 7 MSTATUS VLD HALL ALM H BLK5 9 6 423 1 SHIFTCLEAR ( ESC) EXIT GROUP PRESETPREVS-CTL ID OPE IDNEXT GROUP SEQPAUSESTOP TOUR SEQREV RUNFWD RUN OSD VER MONITOR LOCK OSD SERVICE