Page 21
21 TimeDateFormat=1 ***{ Time-Hour Display format } ***{ Format: TimeHourFormat= } ***{ format 0 - 12 Hour } ***{ format 1 - 24 Hour } TimeHourFormat=0 UNIT section [CAUTION] This section should not be changed. [UNIT] ***{ The unit ID should be the same as the one defined in } ***{ the Global Admin database for this unit. } ***{ For single-unit systems, use ID=1. (ID=0 is invalid) } ID=1 RMS section [CAUTION] This section does not apply to the MPU955 system, and should not be changed. [RMS]...
Page 22
22 RS232ALARM section [CAUTION] This section should not be changed. All RS232C ports can be set in Admin Console for the alarm interface. This section describes the characteristics for the external alarm port only. Other use of the port, such as for an external controller, must be configured using Admin Console. [RS232ALARM] ***{ This section is optional. It is not required unless } ***{ System defaults are not acceptable. Delete the } ***{ single asterisks below to make this section active. }...
Page 23
23 The factory default settings below are up is commented out by “*”. default=192.168.200.1 ***{ Network entries must be grouped together although any number of entries is allowed. } ***{ Format: network=,, } *network=64.0.0.0,192.168.200.44,255,0,0,0 *network=88.0.0.0,192.168.200.88,255,0,0,0 *network=33.5.0.0,192.168.200.66,255,0,0,0 *network=64.0.0.0,192.168.200.55,255,0,0,0 ***{ Host entries must be grouped together although any number of entries is allowed. } ***{ Format: host=, }...
Page 24
ID ID 24 This section indicates the contents of the default database - sample.adm - that is included on the CD-ROM. GX DEVICES Default Database Contents 1 2 3 4 5 6I/F 0 0 0 0 0 0IPA 192.168.1.1 192.168.1.2 192.168.2.1 192.168.2.2 192.168.3.1 192.168.4.1EA 00:00:00:00:00:00 00:00:00:00:00:00 00:00:00:00:00:00 00:00:00:00:00:00 00:00:00:00:00:00 00:00:00:00:00:00ENC Input port 1 - 4 5 - 8 9 - 12 13 - 16 – –DEC Output port – – – – 1 - 4 5 - 8GXDIN Input port – – – – – –Address AB 00 00 00 00 10 10C 1 2 3...
Page 25
ID ID ID 25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16Area 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Priority 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3Boot File – – – – – – – – – – – – – – – keyetherModel WV-CU350 WV-CU350 WV-CU350 WV-CU350 WV-CU350 WV-CU350 WV-CU350 WV-CU350 WV-CU350 WV-CU350 WV-CU350 WV-CU350 RS232 RS232 RS232 WV-CU850IPA 127.0.0.1 127.0.0.1 127.0.0.1 127.0.0.1 127.0.0.1 127.0.0.1 127.0.0.1 127.0.0.1 127.0.0.1 127.0.0.1 127.0.0.1 127.0.0.1 127.0.0.1 127.0.0.1 127.0.0.1 172.18.0.200EA 00:00:00:00:00:00...
Page 28
If operator ID and password are correct, OK will appear for 2 seconds on the LCD display. Note:If an operator ID and password error have occurred, NG will appear for 2 seconds on the LCD display with a beep sound, then the Log-in procedure automatically returns to the start. Log-out This function is used when an operator is leaving the con- troller, or no longer requires access to the system. 1. Hold down the [LOGOUT]key and then press the [CAMERA (ENTER)]key to log out. NO OPERATOR is displayed on the...
Page 29
After log-in, the following operations are available for con- trolling the system. The operation begins with selecting a monitor; then select a camera to be displayed on the active monitor screen. Monitor Selection 1. Select the desired monitor number by pressing the numeric keys, then press the [MONITOR]key to exe- cute the selection. The selected monitor number is now displayed on the MONITOR display of the controller. 2. Pressing the [NEXT]key while holding down the [MON- ITOR]key will select the...
Page 30
30 Priority Lock This function is used to retain control of a monitor for an operator, even after that operator has selected another monitor. Caution:This function will prevent operators with a lower priority from gaining control of a monitor. However, higher priority operators may still gain control of that monitor. Applying Priority Lock 1. Select the desired monitor to apply Priority Lock. Refer to the Monitor Selection. 2. Pressing the [MONITOR]key while holding down the [SHIFT]key will toggle the...