z INCOM/MIC ScreenThis menu is used for the unit’s intercom settings .
Configure the camera’s intercom setting on the camera .
       indicates the factory default setting .
Item Setting 
value Remarks
4W/RTS  
IN LEVEL
–40 .0dB │
0dB │
20 .0dB Set the input level for the intercom 
(4-WIRE and RTS) signal .
(0 .5dB increments)
4W/RTS  
OUT LEVEL
–40 .0dB │
0dB │
20 .0dB Set the output level for the intercom 
(4-WIRE and RTS) signal .
(0 .5dB increments)
RTS CANCEL –40 .0dB
│
31 .5dB Set the noise...

Page 32

32
z
z START UP ScreenThis menu is used to set the control that is performed when the unit’ s 
power is turned on .
       indicates the factory default setting .
Item Setting 
value Remarks
CAM POWER
OFF ON
REMOTE Set the control of the camera’s power 
that is to be performed when the unit’s 
power is turned on .
OFF:
   
The camera’s power will not come on 
even when the unit’s power is turned 
on . In this case, “HEAD POWER” 
must be set to ON on the operation 
panel of the ROP  .
ON:
    The camera’s...

Page 33

33
z
z NETWORK ScreenThis screen displays the network addresses .
z
z On this screen, the addresses cannot be changed .
Item Remarks
IP ADDRESS Displays the IP address .
SUBNETMASK Displays the subnet mask .
DEFAULT 
GATEWAY Displays the default gateway
 .
PORT Displays the port number  .
MAC ADDRESS Displays the MAC address .
z
z VERSION ScreenThis menu is used to display the version information for the application 
software and FPGA .
Item Remarks
SOFTWARE Displays the version of the software installed...

Page 34

34
z
z PM OPERATION STATUS ScreenThis menu is used to set ON or OFF for the operation items to display 
on the picture monitor  .
      indicates the factory default setting .
Item Setting 
value Remarks
STATUS 
DISPLAY TIME
0 sec
2 sec
4 sec Set the length of the status display time .
Set the time in 1-second increments .
When the status of an item that has 
been set to ON on this menu has 
changed, the status is displayed on the 
picture monitor for just the length of 
time that was set for STATUS...

Page 35

35
Table of adjustment setting ranges
Names in [     ] apply when menu operations are performed from a computer using a Web browser .
„
„ OPERATION menu
Menu
Item Adjustment setting range Initial value
SETTING1
(pages 11 and 27) CCU MODE
1080/59 .94i, 1080/50i 59 .94 Hz: 1080/59 .94i
50 Hz:  1080/50i
SDI RETURN1 HD, SD HD
SDI RETURN2 HD, SD HD
SDI OUTPUT 1&2 HD, SD HD
SDI OUTPUT 3&4 HD, SD HD
SDI OUTPUT 3&4
  NORMAL/PM
[SDI OUTPUT 3&4 (NORMAL/PM)] NORMAL, PM
PM
COMPOSITE
  NORMAL/PM
[COMPOSITE...

Page 36

36
MenuItem Adjustment setting range Initial value
INCOM/MIC
(pages 21 and 31) 4W/RTS IN LEVEL
–40 .0dB to 20 .0dB (0 .5dB increments) 0dB
4W/RTS OUT LEVEL –40 .0dB to 20 .0dB (0 .5dB increments) 0dB
RTS CANCEL –40 .0dB to 31 .5dB (0 .5dB increments) Factory setting
GAIN PGM 0dB, 20dB 0dB
MIC1 LEVEL
[MIC LEVEL MIC1] –40 .0dB to 20 .0dB (0 .5dB increments)
0dB
MIC2 LEVEL
[MIC LEVEL MIC2] –40 .0dB to 20 .0dB (0 .5dB increments)
0dB
CM/DM CM, DM DM
CCU INCOM MIC –40 .0dB to 12 .0dB (0 .5dB increments) 0dB...

Page 37

37
MenuItem Adjustment setting range Initial value
PM OPERATION STATUS
(pages 24 and 34) STATUS DISPLAY TIME
0, 2, 4
[0 sec, 2 sec, 4 sec] 4
[4 sec]
MASTER GAIN
[MANUAL OPERATION STATUS 
MASTER GAIN] ON, OFF
ON
SHUTTER
[MANUAL OPERATION STATUS 
SHUTTER] ON, OFF
ON
LENS EXTENDER
[MANUAL OPERATION STATUS 
LENS EXT] ON, OFF
ON
FILTER
[MANUAL OPERATION STATUS 
FILTER] ON, OFF
ON
SCENE FILE
[MANUAL OPERATION STATUS 
SCENE FILE] ON, OFF
ON
REF LOAD
[MANUAL OPERATION STATUS 
REF LOAD] ON, OFF
ON
AUTO OPERATION...

Page 38

38
Connector pin assignment table
[COMMUNICATION]JBY-25S-1A3F(LF)(SN) (J .S .T . Mfg . Co ., Ltd .)
Pin No .Signal Flow of signals Remarks
1 INCOM 1 OUT (H) CCU → SYSTEM0 dBm, 600 Ω (4W)/1 V [p-p] (RTS)
z
z Select “4W” or “RTS” and “INCOM1” or “INCOM2” with the “INCOM switches” on the 
rear panel .   
[When “RTS” is set, terminate pins 1 and 3 of the connector using a terminating 
resistor (200 Ω) .]
2
INCOM 1 OUT (C) CCU → SYSTEM
3 INCOM 1 (GND)
4 INCOM 1 IN (H) SYSTEM → CCU
5 INCOM 1 IN (C) SYSTEM →...

Page 39

39
[MIC OUT 1], [MIC OUT 2]HA16RV-3PG(76) (Hirose Electric Co ., Ltd .)
Pin No .Signal Flow of signals Remarks
1 SHIELD 0 dBm, 600 Ω
2 HOT CCU → SYSTEM
3 COLD CCU → SYSTEM
[MSU]This connector is for future function expansion .
HR10G-10R-10SC(71)  (Hirose Electric Co ., Ltd .)
Pin No .Signal Flow of signals
1 CSU CONT (H) CCU → MSU
2 CSU CONT (C) CCU → MSU
3 CSU DATA (H) MSU → CCU
4 CSU DATA (C) MSU → CCU
5 TALLY R CCU → MSU
6 TALLY G CCU → MSU
7 HEAD POWER CCU → MSU
8 ALARM 1 CCU → MSU
9 ALARM 0 CCU →...

Page 40

Index
x
xA
ANALOG GAIN Screen   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  22, 32
x
xB
BAR ID Screen   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  20, 30
x
xH
HD/SD PHASE Screen   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Start reading Panasonic Camera Control Unit Ak Hcu200 Operating Instructions

Related Manuals for Panasonic Camera Control Unit Ak Hcu200 Operating Instructions

All Panasonic manuals