    ABCDEF GH
    2Attach the outer member brackets to the rack.
    Check that the height is the same for the left and
    right brackets.
    3Remove the four screws at the front for attaching
    the left and right side panels.
    4Attach the AJ-MA75P rack mount adapter using
    the same 4 screws.
    1Attach the inner members of the slide rails.
    Refer to the figure below for the locations where
    the screws are to be attached. The unit can be mounted into a 19-inch standard rack
    using the optional rack-mounting adaptors (AJ-
    MA75P). For the installation rails, it is recommended
    that the 18-inch rail and bracket (model number
    CC3061-99-0400) by Chassis Trak be used. (The
    complete slide rail and bracket unit is not available
    from Panasonic.) 
    For further details, consult your dealer.
    Rack mounting
    
    OThe length of the screws used is subject to
    restriction. (B, G: 10 mm, E: 6 mm)
    OAttach the inner members at the same
    symmetrical positions on the left (L) side.
    OFix the members in place using 3 screws on
    each side (total: 6 screws).
    OThe letters “A” to “H” are not actually marked on
    the side panels.
    Inner member Locations where the screws are secured on the right
    (R) side of the inner members of the slide rails
    Rack-mounting adaptors
    5Remove the 4 rubber legs from the bottom of the
    unit, and install the unit in the rack.
    After the unit has been installed, check that it
    moves smoothly along the rails.
    Standard rack
    Fasten it to the rack with set
    screws.
    
    OKeep the temperature inside the rack to between
    41°F to 104°F (5°C to 40°C).
    OBolt the rack securely to the floor so that it will not
    topple over when the VTR is drawn out. 
    						
    							62
    This unit is equipped with an auto head cleaning
    function which automatically reduces the amount of
    dirt on the video heads. However, in order to
    maximize the unit’s reliability, it is recommended that
    the video heads be cleaned as and when appropriate.For further details on how to actually clean the heads,
    consult with one of our service companies or with your
    dealer.
    Video head cleaning
    Condensation occurs due to the same principle
    involved when droplets of water form on a window
    pane of a heated room. It occurs when the unit or tape
    is moved between places where the temperature or
    humidity varies greatly or when, for instance:
    OIt is moved to a very humid place full of steam or a
    room immediately after it has been heated up.
    OIt is suddenly moved from a cold location to a hot or
    humid location.When moving the unit to locations such as these,
    leave it standing for about 10 minutes rather than
    switching on the power immediately.
    If condensation occurs in the unit, “E-20” will flash on
    the counter display and the cassette will be
    automatically ejected.
    Leave the unit with the power on until “E-20” is
    cleared from the display.
    Condensation
    Before starting any maintenance work, switch the
    power to OFF and, holding the plug, unplug the cord
    from the socket.
    Use a soft cloth to clean the outside of the unit.
    For stubborn dirt or stains, wipe the unit with a cloth
    that has been lightly dampened with well-diluted
    kitchen detergent and wrung out thoroughly.
    After wiping off the dirt with the damp cloth, finish it off
    with a dry cloth.
    Do not use alcohol, benzene, thinners or any other
    solvents as they may affect the color of external parts
    or damage the unit’s coating.
    Maintenance
    Attaching the dust cover
    1Insert the end of the cover
    under the metal plate on the
    inside edge of the top of the
    side panel. 2Insert the end of the cover
    under the metal plate on the
    inside edge of the top of the
    front panel.Dust cover 
    						
    							63
    When a warning occurs in this unit, the error number
    is indicated on the counter display.
    Open the DIAG menu to display a description of the
    error on the counter display or monitor TV.
    When a operational malfunction has occurred in the
    unit, the error number flashes on the counter display.
    DIAG menu
    This display the VTR information.
    VTR information includes “WARNING” information,
    “HOURS METER” (usage time) information and
    “UMID (Unique Material Identifier)” information. A
    DIAG menu appears on the monitor when the monitor
    is connected to the VIDEO OUT 3 connector on the
    connector section.
    
    By installing the SDI board (AJ-YA755G, available as
    an optional accessory) in the VTR, it is also possible
    to display the DIAG menu on a TV monitor which has
    been connected to the SDI OUT 3 connector.
    $Displaying the DIAG menu
    Error messages
    1Press the DIAG button.
    The DIAG menu screen is displayed on the
    monitor, and the message is displayed on the
    counter display.
    2Each time the search button is pressed, the display
    changes as follows: “WARNING” 5“HOURS
    METER” 5“UMID INFO” 5and so on.
    3Press the DIAG button again to return to the
    original display.
    $“WARNING” information display
    OA warning message is displayed whenever a
    warning occurs.
    When warnings have not been detected, “NO
    WARNING” is displayed.
    OWhen multiple warning occur, the descriptions for
    each warning can be checked by turning the search
    dial.
    ON
    OFFPOWERDVDVCPRO
    METER
    L
    R FULL/FINE
    MONITOR SELECT
    HEADPHONESMONITOR MIXINPUT SELECTPREVIEW/PREVIEWAUTO EDITPREROLLVIDEOCH1
    REC
    AUDIOCH2 CH1 CH2TCPRESETMENU SET DIAGSUPER REC INHINT TCGMODECONTROLON
    OFFUNITY
    VA RPB
    COUNTERRESET
    A  IN
    TRIM
    SET
    OUT IN
    A  OUTCH2 CH1INSERTASSEMVIDEO CUE TCSTAND BY
    EDIT
    REW STOPPLAY REC PLAYER
    RECORDER
    FF
    JOGSHTLSLOW
    TAPE
    EEONREGENPRESETEXITOFFREMOTELOCAL
    1/3
    2 
    						
    							64
    H04
    F LOADINGDisplays the number of times front loading has
    been performed in single units.
    $Displaying the “HOURS METER”
    information
    Turn the search dial to move the cursor (2). 
    The description for the item where the cursor is
    located is shown on the counter display.If “T&S&M” is selected in the setup menu No. 008
    (DISPLAY SEL), a message appears in the mode
    display whenever a warning or error occurs. When
    multiple events occur, the event with the highest
    priority is displayed.
    
    OThe resettable items in the “HOURS METER”
    information are reset by the shop when performing
    maintenance or other work.
    OThe search buttons and the search dial cannot be
    operated while the DIAG menu is displayed.
    Error messages
    No./Item Description
    Ser
    222222222
    Displays the unit’s serial No.
    Priority Display/Description
    High
    LowError messages (See error message table)
    When an operational malfunction has occurred in
    the unit, the error number flashes and the error
    message is indicated on the counter display.
    INT SG
    When SG has been selected as the input signal with
    the INPUT SELECT buttons, pressing the REC
    button or the EDIT button (E-E mode) will display
    “INT SG” for the first two seconds.
    This is also displayed for the first two seconds when
    starting editing.
    NO INPUT
    If there is no input signal (except for analog audio) to
    the connector selected using the INPUT SELECT
    buttons, pressing the REC button or the EDIT button
    (E-E mode) will display “NO INPUT” for the first two
    seconds. 
    This is also displayed for the first two seconds when
    starting editing.
    Warning messages (See error message table)
    When a warning occurs in this unit, the error number
    and warning message are indicated on the counter
    display.
    When multiple warnings occur, the warning with the
    highest priority is displayed. H00
    OPERATIONDisplays the time that the power has been
    supplied in one-hour units.
    H01
    DRUM RUNDisplays the time that the drum has been
    rotating in one-hour units.
    H02
    TAPE RUNDisplays the time that the tape has been running
    during FF, REW, PLAY, SEARCH (JOG, SLOW,
    SHTL), REC, and EDIT modes (except for STILL
    in the JOG, SLOW or SHTL mode) in one-hour
    units.
    H03
    THREADINGThe number of times for threading (loading)/
    unthreading (unloading) is displayed in single
    units.
    H11
    DRUM RUNrDisplays the time that the drum has been
    rotating in one-hour units. (Can be reset)
    H13
    THREADINGrThe number of times for threading (loading)/
    unthreading (unloading) is displayed in single
    units. (Can be reset)
    H30
    POWER ONThe number of times the power has been turned
    on is displayed in single units. H12
    TAPE RUNrDisplays the time that the tape has been running
    during FF, REW, PLAY, SEARCH (JOG, SLOW,
    SHTL), REC, and EDIT modes (except for STILL
    in the JOG, SLOW or SHTL mode) in one-hour
    units. (Can be reset)
    H14
    F LOADINGrDisplays the number of times front loading has
    been performed in single units.
    (Can be reset)
    $UMID information display
    This is displayed when UMID information is present
    on the input signal in E-E mode.
    This lamp lights during tape playback when UMID
    information has been recorded on the tape.
    “NO-INFO” is displayed when there is no UMID
    information.
    Item Display/Description
    MATNOMaterial number
    COPYInstance number (No. of copies)
    OWNRCountry, organization, user
    POSReception status from GPS satellites when
    recording spatial coordinates (height above sea
    level, longitude and latitude):
    HOLD: No reception from any satellite
    2D: Reception possible, but number of
    satellites is insufficient. Height above
    sea level will not be accurate.
    3D: Good reception
    DTAEDate
    TIMEUTC (Coordinated Universal Time) and time
    difference with UTC 
    						
    							65
    Warning messages
    Error messages
    PriorityOMonitor display
    ODescription
    OVTR operation and corrective action
    HighE-04 (UNKNOWN SIG)
    This appears when the SDTI input signals are not
    DVCPRO or DV format signals. (The data stream
    format complies with the SMPTE 321M standard.)
    VTR:No recording operations can be performed.
    OCheck whether the SDTI input has been
    connected properly.
    (This warning is displayed when SDI signals are
    being input.)
    PriorityOMonitor display
    ODescription
    OVTR operation and corrective action
    Low
    E-01 (LOW RF)
    This appears when envelope levels approximately
    1/3 that of normal levels are detected for more than
    one second during playback, recording, or editing.
    VTR:Operation continues.
    OClean the video heads.
    E-02 (HIGH ERROR RATE)
    This appears when the error rate has increased to
    the extent that correction or interpolation was
    performed on either the video or audio signals.
    VTR:Operation continues.
    OClean the video heads. E-11 (NOT 1a25M SIG)
    This appears when the SDTI input signals are not
    DVCPRO (25 Mbps) format 1atransfer signals.
    VTR:No recording operations can be performed.
    OCheck the SDTI input signals.
    E-00 (SERVO NOT LOCKED)
    This appears when the servo is not locked for three
    or more seconds during playback, recording, or
    editing.
    VTR:Operation continues.
    OCheck the tape.
    A tape recorded other than NTSC format may
    have been inserted.
    E-16 (INVALID VIDEO SIG)
    This appears when the compressed video signals in
    the SDTI input signals are invalid.
    OThis warning appears only during recording
    operations.  In cases like this, no signals are
    recorded on the tape and only the erasure of the
    existing signals will be performed.
    VTR:Operation continues.
    No editing operations can be performed.
    OCheck the SDTI input signals.
    Playback signals of tape on which material has
    not been recorded may be being input.
    E-17 (INVALID AUDIO SIG)
    This appears when the audio signals in the SDTI
    input signals are invalid.
    OThis warning appears only during recording
    operations.  In cases like this, the signals are
    recorded with the audio signals muted.
    VTR:Operation continues.
    No editing operations can be performed.
    OCheck the SDTI input signals.
    Signals from other than a VTR with 1aplayback
    may be being input.
    E-18 (INVALID TC SIG)
    This appears when the time codes in the SDTI input
    signals are invalid.
    OThis warning appears only during recording
    operations.  In cases like this, the internally
    generated time codes are recorded.
    VTR:Operation continues.
    No editing operations can be performed.
    OCheck the time code being input from the
    components.
    E-10 (FAN STOP)
    This is displayed when the fan motor stops.
    VTR:Operation continues.
    OCheck that nothing is obstructing the fan
    movement.
    E-09 (NO RF)
    This appears during playback when a blank section
    (tape blank) lasting for one or more seconds has
    been detected.
    Such a section is identified as a tape blank when all
    of the following conditions are met.
    ONo head outputs
    ONo playback data readout
    ONo CTL (Excluding DV and DVCAM tapes)
    VTR:Operation continues.
    OCheck the tape.
    A tape on which material has not been recorded
    may have been inserted. 
    						
    							66
    Error messages
    Error messages
    E-55
    UNLOAD
    ERRORIf the tape has not been taken up during
    unloading, this error number flashes on the
    display.
    VTR:STOP
    OSet the POWER switch to OFF and then to
    ON again.
    E-53
    WINDUP
    ERRORIf there is an abnormally large discrepancy
    between the amount of tape taken up by the
    take-up reel and the amount of tape supplied by
    the supply reel while the tape is traveling after
    the total amount of the tape begins to be
    detected, this error number flashes on the
    display.
    VTR:STOP
    OSet the POWER switch to OFF and then to
    ON again.
    E-52
    W-UP REEL
    NOT ROTAIf the take-up reel fails to take up the tape while
    the tape is traveling in the state where the total
    amount of the tape has not yet been detected
    after the cassette was inserted, this error
    number flashes on the display.
    VTR:STOP
    OSet the POWER switch to OFF and then to
    ON again.
    E-38
    SERVO FG
    ERRORIf automatic adjustment of the reel and capstan
    rotation in eject status was not performed
    correctly when the power was turned on, this
    error number flashes on the display.
    VTR:STOP
    OSet the POWER switch to OFF and then to
    ON again. DisplayODescription
    OVTR operation and corrective action
    E-29
    FRONT LOAD
    MOTORThe unit switches to eject mode and if the
    cassette fails to move up within 6 seconds, this
    error number flashes on the display.
    OIf the cassette does not move down inside the
    machine even when 6 seconds have elapsed
    since the cassette was inserted, the VTR is
    transferred to the eject mode.
    VTR:STOP
    OSet the POWER switch to OFF and then to
    ON again. E-20
    DEWIf condensation is detected, the error number
    flashes and the unit transfers to eject mode. The
    drum rotates after the cassette is ejected to
    eliminate the condensation.
    Once the unit is released from condensation
    status, the error message display is cleared and
    the VTR is able to be used.
    OIf condensation is detected in the eject mode,
    the drum starts rotating as soon as it is
    detected.
    OIf condensation is detected when the cassette
    has been inserted, the drum rotation is
    stopped, and after the tape is ejected, the
    drum starts rotating.
    VTR:EJECT
    OLeave the power on and wait.
    DisplayODescription
    OVTR operation and corrective action
    E-31
    LOADING
    MOTORIf the unloading operation is not completed
    within 6 seconds, this error number flashes on
    the display.
    OWhen the loading operation is not completed
    within 6 seconds, the VTR is transferred to the
    eject (unloading) mode.
    VTR:STOP
    OSet the POWER switch to OFF and then to
    ON again.
    E-37
    SERVO COMM
    ERRORIf 10 seconds or more elapses and the servo
    microcomputer has not followed orders issued
    by the system control microcomputer, this error
    number flashes on the display.
    VTR:STOP
    OSet the POWER switch to OFF and then to
    ON again.
    E-35
    SERVO
    CONTROL
    ERRORIf there is no response from the servo
    microcomputer for 1 second or more, this error
    number flashes on the display.
    VTR:STOP
    OSet the POWER switch to OFF and then to
    ON again.
    E-57
    S-FF/REW
    TIMEOVERIf the start or end processing operation is not
    completed, this error number flashes on the
    display.
    VTR:STOP
    OSet the POWER switch to OFF and then to
    ON again.
    E-51
    FRONT LOAD
    ERRORIf the take-up reel rotates without engaging for a
    specific period of time during the start or end
    processing operation while loading is underway
    (half position), this error number flashes on the
    display.
    VTR:STOP
    OSet the POWER switch to OFF and then to
    ON again.
    E-60
    DRUM ROTA
    TOO FASTIf the cylinder motor speed is abnormally high,
    this error number flashes on the display.
    VTR:STOP
    OSet the POWER switch to OFF and then to
    ON again.
    E-59
    DRUM ROTA
    TOO SLOWIf the cylinder motor speed is abnormally low,
    this error number flashes on the display.
    VTR:STOP
    OSet the POWER switch to OFF and then to
    ON again.
    E-61
    CAP ROTA
    TOO SLOWIf the capstan motor speed is abnormally low,
    the error number flashes on the display.
    VTR:STOP
    OSet the POWER switch to OFF and then to
    ON again. 
    						
    							67
    Error messages
    Error messages
    DisplayODescription
    OVTR operation and corrective action
    E-78
    M-IF COMM
    ERRORIf a problem has been encountered in
    communication between the servo
    microcomputer and mechanism relay board, this
    error number flashes on the display.
    VTR:STOP
    OSet the POWER switch to OFF and then to
    ON again. E-67
    T REEL ROTA
    TOO FASTIf the take-up reel motor speed is abnormally
    high, the error number flashes on the display.
    VTR:STOP
    OSet the POWER switch to OFF and then to
    ON again. E-64
    S REEL ROTA
    TOO FASTIf the supply reel motor speed is abnormally
    high, the error number flashes on the display.
    VTR:STOP
    OSet the POWER switch to OFF and then to
    ON again.
    E-69
    T REEL
    TORQUE ERRIf excess torque being applied to the take-up
    reel motor is detected, the error number flashes
    on the display.
    VTR:STOP
    OSet the POWER switch to OFF and then to
    ON again.
    E-70
    S REEL
    TORQUE ERRIf excess torque being applied to the supply reel
    motor is detected or an abnormal current flowing
    to the current detection resistor is detected, this
    error number flashes on the display.
    VTR:STOP
    OSet the POWER switch to OFF and then to
    ON again.
    E-71
    CAP TENSION
    ERRORIf abnormal tension at the supply side is
    detected in the capstan mode, the error number
    flashes on the display.
    VTR:STOP
    OSet the POWER switch to OFF and then to
    ON again.
    E-72
    REEL
    TENSION
    ERRORIf abnormal tension at the supply side is
    detected in the reel mode, the error number
    flashes on the display.
    VTR:STOP
    OSet the POWER switch to OFF and then to
    ON again.
    E-73
    REEL DIR
    UNMATCHIf the take-up reel motor has rotated in the
    reverse direction, this error number flashes on
    the display.
    VTR:STOP
    OSet the POWER switch to OFF and then to
    ON again.
    E-74
    DRUM
    TORQUE
    ERRORIf excess torque being applied to the cylinder
    motor is detected, this error number flashes on
    the display.
    VTR:STOP
    OSet the POWER switch to OFF and then to
    ON again.
    Consult your dealer if the error message is still
    displayed even after restarting the unit. 
    						
    							68
    The VTR can be operated by commands when the
    RS-232C interface is used.
    (See command table on pages 71, 72.)
    $Conditions for acknowledging
    commands from RS-232C interface
    OThe front panel CONTROL switch must be at
    REMOTE.
    OThe setup menu No. 204 “RS232C SEL” must be
    ON.
    If the above conditions are not met, [ACK] + [STX]
    ER001 [EXT] is returned to the external unit.
    Whether the [ACK] code is returned depends on the
    setting which has been selected for setup menu
    item No. 209 “RETURN ACK”.
    Hardware specifications
    External interface specifications
    RS-232C interface
    OConnector specifications
    Connector:
    D-SUB 25-pin (crossover cable supported)
    OExample of connection with controller (PC)
    Using crossover cable with D-SUB 25-pin
    connectors
    Pin No. Signal Description
    1FG Protective ground
    (Frame ground)
    2RXD Received data
    (Data is sent to PC.)
    3TXD Transmitted data
    (Data is received from PC.)
    4CTS Clear to send
    (Shorted with pin 5.)
    5RTS Request to send
    (Shorted with pin 4.)
    6DTR Data terminal ready
    (No processing)
    7SG Signal ground
    (Signal ground)
    20DSR Data set ready (+ voltage output after
    communication enable status)
    PC side
    (D-SUB 25-pin connector)VTR side
    FG
    TXD
    RXD
    RTS
    CTS
    DSR
    SG
    DTR1
    2
    3
    4
    5
    6
    7
    20FG
    RXD
    TXD
    CTS
    RTS
    DTR
    SG
    DSR 1
    2
    3
    4
    5
    6
    7
    20
    Using crossover cable with D-SUB 9-pin and 25-pin
    connectors
    PC side
    (D-SUB 9-pin connector)VTR side
    RXD
    TXD
    DTR
    SG
    DSR
    RTS
    CTS2
    3
    4
    5
    6
    7
    8FG
    RXD
    TXD
    CTS
    RTS
    DTR
    SG
    DSR 1
    2
    3
    4
    5
    6
    7
    20 
    						
    							69
    Software specifications (Protocol)
    1. Communication parameters
    RS-232C interface
    Communication
    systemAsynchronous, full duplex
    Communication
    speed300/600/1200/2400/4800/9600
    Bit length7bit/8 bit
    Stop bit1 bit/2 bit
    Parity bitNONE/ODD/EVEN
    ACK codeACK code returned/ACK code not returned
    
    The ACK code is what is returned from the
    VTR to the controller when data has been
    successfully sent from the controller.
    The underlining indicates the factory settings.
    Communication
    parameterSetup menu item
    Communication
    speedNo.205 BAUD RATE
    Bit lengthNo.206 DATA LENGTH
    Stop bitNo.207 STOP BIT
    Parity bitNo.208 PARITY
    ACK codeNo.209 RETURN ACK
    Any changes to the settings can be made using the
    setup menu items listed below.
    2. Send format
    [controller (PC) 5VTR]
    $Data format
    [STX] [command] [:] [data] [ETX]
    02h XX XX XX 3Ah XX.....
    XX 03h
    20H
    						
    							70
    RS-232C interface
    3. Return format
    [VTR 5controller (PC)]
    The following responses are made to the command. If
    necessary, more than one response is made.
    $When the communication has terminated
    normally
    1. The receive completion message is returned.
    [ACK]
    06h
    2. The execution completion message is returned.
    [STX] [command] [data] [ETX]
    02h XX XX XX XX.....
    XX 03h
    [command] :
    This is the message (data) which is returned or
    the execution completion message identifier.
    [data] :
    This is the data to be returned. It can be omitted.
    Example:
    Send command
    Return message (data)
    [STX] OPL [ETX]5[ACK] [STX] OPL [ETX]
    $When the communication has terminated
    abnormally
    [NACK]
    15h
    $When processing is not possible due to
    incorrect data or trouble in the VTR
    1. The receive completion message is returned.
    [ACK]
    06h
    2. An error code is returned.
    [STX] [E R N
    1N2N3] [ETX]
    02hError code03h
    4. Error code table
    ER001 :Invalid command
    OUnsupported command received.
    OError in command execution
    ER002 :Parameter error
    ER102 :VTR mode error (front loading motor)
    ER103 :VTR mode error (loading motor)
    ER104 :VTR mode error (drum, capstan system)
    ER105 :VTR mode error (reel system)
    ER106 :VTR mode error (tension system)
    ER108 :VTR dew error
    ER1FF :VTR system error 
    						
    All Panasonic manuals Comments (0)