Panasonic Aj Hdc27a Servece Information Manual
Here you can view all the pages of manual Panasonic Aj Hdc27a Servece Information Manual. The Panasonic manuals for Camera are available online for free. You can easily download all the documents as PDF.
Page 21
INF-19(CAM DESIGN MENU) ITEMSETTING RANGEINIT. VA L U EMEANING of SETTING & OUTLINE of FUNCTION LSI REG SET1 A (0) or B (1) ----- ----- Not used MEMORY SEL ----- ----- Not used ADR_H ----- ----- ADR_L ----- -----Data address of Flash memory (at CAM_SYS) DATA_H ----- ----- DATA_L ----- -----Data value of Flash memory (at CAM_SYS) WRITE ----- ----- STORE command of Adjustment data (To Flash memory) READ ----- ----- READ command of Adjustment data (From Flash memory) LSI REG SET2 A (0) or B (1) ----- -----...
Page 22
INF-20(CAM DESIGN MENU) ITEMSETTING RANGEINIT. VA L U EMEANING of SETTING & OUTLINE of FUNCTION DSP D/A SET GAIN G ----- ----- G A/D converter input gain adjustment GAIN B ----- ----- B A/D converter input gain adjustment GAIN R ----- ----- R A/D converter input gain adjustment CPL G ----- ----- G A/D converter input clamp level adjustment CPL B ----- ----- B A/D converter input clamp level adjustment CPL R ----- ----- R A/D converter input clamp level adjustment ND POSITION1 R -127-+128 0 R GAIN...
Page 23
INF-21 9-4. VTR SERVICE 2/3 ITEMSETTING RANGEINIT. VA L U EBackupBackup (INH.)MEANING of SETTING & OUTLINE of FUNCTION T TORQUE -128-+127 0 OK NG Take-up reel torque adjustment S TORQUE -128-+127 0 OK NG Supply reel torque adjustment PG SHIFT 100 ----- ----- PG shifter adjustment HSW_A_RIZE 0-4095 0x500 OK NG Rising edge HSW_A_FALL 0-4095 0x500 OK NG Falling edge HSW_C_RIZE 0-4095 0x500 OK NG Rising edge HSW_C_FALL 0-4095 0x500 OK NG Falling edge RPL GAIN 100 -128-+127 64 OK NG RPL head ATF...
Page 24
INF-22 9-7. TEST MODE ITEM SETTING RANGE INIT. VALUEMEANING of SETTING & OUTLINE of FUNCTION AGING MODE OFF/ON OFFON : TEST MODE (VTR RUNNING TEST) (Repeat 5 minutes REC and 1 minute STAND-BY) 9-8. ERROR LOG ITEM SETTING RANGE INIT. VALUEMEANING of SETTING & OUTLINE of FUNCTION FILE No. 1-5 1 Be able to select 1 through 5. 1 : Old Error Data ® 4 : Recent Error Data 5 : First Error (Cannot delete until execute LOG ALL CLEAR) LOG ALL CLEAR OFF/ON OFF ON : All Clear Finally, turn OFF or POWER OFF....
Page 25
INF-23 10. Adjustment after Optical Unit Replacement When replace the Optical Unit (PRE AMP, CCD PULSE, DRIVE Board included), execute the adjustment as following procedures. In this case, do not need to execute the Optical Unit Adjustment on the “Section 5 : Electrical Adjustment”. 10-1. Input the Adjustment Data 1. Set the Shading Correction to “OFF” as follows. *** CAM MAIN MENU 4 *** < BLACK SHADING > ® CORRECT (DIG) : “ON“ ® “OFF” < WHITE SHADING > ® CORRECT : “ON“ ® “OFF” 2. Input the...
Page 26
INF-24 11.DIAG-MENU Display 11-1-1. Version Display Operation Procedure (CAMERA Part) 1. Open the “ENG menu” (Press “MENU Button” more than 3 second.) 2. Open “CAM MAIN MENU 4 ” page (Press JOG Dial) 3. Select “DIAGNOSTIC” page (Turn and Press JOG Dial), then the Software version for each item can be comfirmed. 11-1-2. How to read the Version Display 11-2-1. Version Display Operation and Hour Meter Display (VTR Part) 1. Open the “ENG menu” (Press “MENU Button” more than 3 second.) 2. Press “MENU...
Page 27
INF-25 11-2-3. How to Reset Hour Meter 1. Open the “Design Menu” and then press “MENU Button”. 2. Open “VTR DESIGN MENU ” page. (Press JOG Dial) 3. Select “VTR DESIGN MENU” item. (Turn & press JOG Dial) 4. After the following figure is displayed, move “®” to the item to reset. **** VTR DESIGN MENU **** ®VTR DESIGN MENU TEST MDOE ERROR LOG VM PLD V0.00 VTR SYSCON V18388a 00.06.13 MENU ALL INIT ®DRUM RUNNING RESET THREADING RESET
Page 28
INF-26 12. Error Rate Display and Confirmation Method 12-1. Error Rate Display Method 1. Open the “VTR SERVICE MENU”. 2. Select “VTR SERVICE 1/3 ” page.(Turn & press JOG Dial) 3. Confirm “BER SPEED ” setting is “SLOW ”. 4. Select BER ADJ by rotating JOG Dial and Select R/P head to be confirmed. BER ADJ item :OFF / L1L3 / R1R3 / L2L4 / R2R4 (exept OFF) 5. The Error rate will be displayed in the Audio meter on the Audio LCD panel. - ¥ ¥¥ ¥ - - 40 - dB - 30 - - 20 - - 10 -- 0 - AUDIO LCD METER Error...
Page 29
INF-27 13. Internal Switch Setting Method The switche settings on each circuit board are shown below. “Factory use only” switches must be set to the “Factory setting”. BOARD Ref. No. SWFACTORY SETTINGFEATURE AUDIO LCD 1-7 ON (FIXED) Factory use onlySW 40001 8 ON Not used 1-5 OFF(FIXED) Factory use onlySW 40002 6 OFF ON : ENG SEQURITY ON 1 ON Factory use only 2 OFF Factory use only 3 ON Factory use onlySW 47001 4 OFF Factory use only SW 41001 - -60 REAR CH1 MIC input level setting (-60dBu / -40dBu) SW...
Page 30
INF-28 14. Circuit board layout E5. CAMERA MOTHER P.C.BOARD E37. HD SDI TX P.C.BOARDE10. VTR SYSCON P.C.BOARDE36. VIDEO MAIN P.C.BOARDE14. RF EQ P.C.BOARD E19. POWER SW P.C.BOARD E24. MENU SW P.C.BOARD E20. TOGGLE SW P.C.BOARD E23. USER SW P.C.BOARD E21. MONITOR SW P.C.BOARD E22. SYNCHRO SW P.C.BOARD E17. AUDIO LCD P.C.BOARD E16. POWER SUB P.C.BOARD E15. POWER MAIN P.C.BOARD E27. EXT DC P.C.BOARD E26. HEAD PHONE P.C.BOARD E40. SDI BNC P.C.BOARD E18. REAR JACK P.C.BOARD E32. OPERAT E P.C.BOARDE38. BACK...