INF-19(CAM DESIGN MENU) ITEMSETTING RANGEINIT. VA L U EMEANING of SETTING & OUTLINE of FUNCTION LSI REG SET1 A (0) or B (1) ----- ----- Not used MEMORY SEL ----- ----- Not used ADR_H ----- ----- ADR_L ----- -----Data address of Flash memory (at CAM_SYS) DATA_H ----- ----- DATA_L ----- -----Data value of Flash memory (at CAM_SYS) WRITE ----- ----- STORE command of Adjustment data (To Flash memory) READ ----- ----- READ command of Adjustment data (From Flash memory) LSI REG SET2 A (0) or B (1) ----- ----- Not Used MEMORY SEL ----- ----- Not Used ADR_H ----- ----- Not Used ADR_L ----- ----- Not Used DATA_H ----- ----- Not Used DATA_L ----- ----- Not Used SHAD DA SET BSHD_R ----- ----- BSHD_G ----- ----- BSHD_B ----- ----- WSHD_G_SUB ----- ----- WSHD_B ----- ----- WSHD_G ----- ----- WSHD_R ----- ----- IRIS_C ----- -----Factory Use only (Fixed at Factory) KNEE APA SET TRESH LEVEL ----- ----- SLOPE ----- ----- FREQ ----- ----- GAIN ----- ----- CORING LVL ----- ----- DTL-COMP (+) ----- ----- DTL-COMP (–) ----- ----- DTL-CLIP (+) ----- ----- DTL-CLIP (–) ----- ----- KNEE SET ----- -----Not Used LSIC REGSET ADR ----- ----- Not Used DATA ----- ----- Not Used WRITE ----- ----- Not Used AD READ TEST IRIS POS ----- ----- Lens iris position information ZOOM POS ----- ----- Lens zoom position information FOCUS POS ----- ----- Lens focus position information LENS EXT ----- ----- Lens extender position information CC FILT ----- ----- CC Filter position information ND FILT ----- ----- ND Filter position information PEAKING ----- ----- Not Used FRAME ----- ----- Not Used ZEBRA ----- ----- Information of Zebra pattern on Viewfinder (ON or OFF Information) MARK SW ----- ----- Not Used
INF-20(CAM DESIGN MENU) ITEMSETTING RANGEINIT. VA L U EMEANING of SETTING & OUTLINE of FUNCTION DSP D/A SET GAIN G ----- ----- G A/D converter input gain adjustment GAIN B ----- ----- B A/D converter input gain adjustment GAIN R ----- ----- R A/D converter input gain adjustment CPL G ----- ----- G A/D converter input clamp level adjustment CPL B ----- ----- B A/D converter input clamp level adjustment CPL R ----- ----- R A/D converter input clamp level adjustment ND POSITION1 R -127-+128 0 R GAIN Adjustment at ND FILTER POSITION 1. COMPENSATIONPOSITION1 B -127-+128 0 B GAIN Adjustment at ND FILTER POSITION 1. POSITION2 R -127-+128 0 R GAIN Adjustment at ND FILTER POSITION 2. POSITION1 B -127-+128 0 B GAIN Adjustment at ND FILTER POSITION 2. POSITION3 R -127-+128 0 R GAIN Adjustment at ND FILTER POSITION 3. POSITION1 B -127-+128 0 B GAIN Adjustment at ND FILTER POSITION 3. POSITION4 R -127-+128 0 R GAIN Adjustment at ND FILTER POSITION 4. POSITION1 B -127-+128 0 B GAIN Adjustment at ND FILTER POSITION 4. < VTR Section > 9-3. VTR SERVICE 1/3 ITEMSETTING RANGEINIT. VA L U EBackupBackup (INH.)MEANING of SETTING & OUTLINE of FUNCTION CONCEAL ON/OFF ON NG NG CONCEAL setting INNER ECC ON/OFF ON NG NG INNER ECC setting OUTER ECC ON/OFF ON NG NG OUTER ECC setting VITERBI ON/OFF ON NG NG VITERBI setting ADJUST ADDRESS 01-24h 01 NG NG ADJUST DATA 00-FFh ----- OK NGEVR adjustment for VTR part BER ADJ OFF/ L1L3/R1R3/ L2L4/R2R4OFF NG NG Error rate display mode setting BER SPEED SLOW/FAST SLOW NG NG Speed setting of Error rate display CW REC OFF/ 20M/5MOFF NG NG Frequency setting for RF,EQ adjustment AUTO EQ ON/OFF ON NG NG AUTO RF,EQ setting RDS. REC ADJ OFF/ L1/L3/ R1/R3/ L2/L4/ R2/R4OFF NG NG Head select for RDS (REC SIGNAL DETECTION SYSTEM) adjustment RDS. TYPE OFF/BOTH/ REC/SPLAYBOTH OK NG RDS setting SERVO MODE ATF/CTL ATF NG NG Servo mode setting
INF-21 9-4. VTR SERVICE 2/3 ITEMSETTING RANGEINIT. VA L U EBackupBackup (INH.)MEANING of SETTING & OUTLINE of FUNCTION T TORQUE -128-+127 0 OK NG Take-up reel torque adjustment S TORQUE -128-+127 0 OK NG Supply reel torque adjustment PG SHIFT 100 ----- ----- PG shifter adjustment HSW_A_RIZE 0-4095 0x500 OK NG Rising edge HSW_A_FALL 0-4095 0x500 OK NG Falling edge HSW_C_RIZE 0-4095 0x500 OK NG Rising edge HSW_C_FALL 0-4095 0x500 OK NG Falling edge RPL GAIN 100 -128-+127 64 OK NG RPL head ATF pre-filter gain adjustment RPL LIN 100 OFF/ON OFF NG NG RPL head LISTA linearity adjustment CTL ADJ OFF/ON OFF NG NG CTL Adjust mode setting X VALUE SET OFF/ON OFF NG NG X value adjustment X VALUE 100 -128-+127 0 OK NG Fine adjustment for X value TRK VAL 100 -128-+127 0 NG NG CTL tracking offset setting SERVO MODE ATF/CTL ATF NG NG Servo mode setting 9-5. VTR SERVICE 3/3 ITEMSETTING RANGEINIT. VA L U EBackupBackup (INH.)MEANING of SETTING & OUTLINE of FUNCTION AUDIO PB SEL CH1,2/ CH3,4/ CH5,6/ CH7,8CH1,2 NG NG AUDIO SAVE ACTIVE/OFFACTIV ENG NG AUDIO CH7/8 EE FORCH/ EE,PBEE,PB OK OK 9-6. VTR DESIGN MENU ITEM SETTING RANGE INIT. VALUEMEANING of SETTING & OUTLINE of FUNCTION MENU ALL INIT ----- ----- DRUM RUNNING RESET----- ----- THREADING RESET----- -----
INF-22 9-7. TEST MODE ITEM SETTING RANGE INIT. VALUEMEANING of SETTING & OUTLINE of FUNCTION AGING MODE OFF/ON OFFON : TEST MODE (VTR RUNNING TEST) (Repeat 5 minutes REC and 1 minute STAND-BY) 9-8. ERROR LOG ITEM SETTING RANGE INIT. VALUEMEANING of SETTING & OUTLINE of FUNCTION FILE No. 1-5 1 Be able to select 1 through 5. 1 : Old Error Data ® 4 : Recent Error Data 5 : First Error (Cannot delete until execute LOG ALL CLEAR) LOG ALL CLEAR OFF/ON OFF ON : All Clear Finally, turn OFF or POWER OFF. ERROR CODE E-00 SEQUENCE NO 00 DATE 00/01/01 TIME 12 : 34 : 56 OPERATION TIME000000Hr TAPE TOTAL 120min TAPE REMAIN 90min BATTERY METER 1-F Example : “ a-F” “ a” indicates the meter number. ”-F” indicates the blink (flash). OBJ/MODE 00 00 00 : 00 : 00 00 00 12 : 34 : 56 Indicate the time when OBJ/MODE occurred. 00 00 00 : 00 : 00 00 00 12 : 34 : 56 Upper - occurred lately 00 00 00 : 00 : 00 00 00 12 : 34 : 56 ¯ ¯ 00 00 00 : 00 : 00 00 00 12 : 34 : 56 Lower - occurred formerly 00 00 00 : 00 : 00 00 00 12 : 34 : 56
INF-23 10. Adjustment after Optical Unit Replacement When replace the Optical Unit (PRE AMP, CCD PULSE, DRIVE Board included), execute the adjustment as following procedures. In this case, do not need to execute the Optical Unit Adjustment on the “Section 5 : Electrical Adjustment”. 10-1. Input the Adjustment Data 1. Set the Shading Correction to “OFF” as follows. *** CAM MAIN MENU 4 *** < BLACK SHADING > ® CORRECT (DIG) : “ON“ ® “OFF” < WHITE SHADING > ® CORRECT : “ON“ ® “OFF” 2. Input the adjustment data following the Adjustment Data Sheet which is included with optical unit. < Items mentioned on the Adjustment Data Sheet > (8 items) *** CAM DESIGN MENU *** < VDRIVE 1 > ® R-SUB® R-RESET DC ® G-SUB® G-RESET DC ® B-SUB® B-RESET DC *** CAM DESIGN MENU *** < VDRIVE 2 > ® H1-DC ® VSHIN 3. Input or execute the following setting by menu. (Memory of Setting Value) *** CAM DESIGN MENU *** < LSI REG SET 1 > ® ADR_H : “FF” (input) ® ADR_L : “01” (input) ® WRITE : “OFF” ® “ON” (execute) 10-2. Electrical Adjustment Execute the Confirmation and Adjustment as following items. (Refer to “Section 5 : Electrical Adjustment”) 1. 0IRE PED Adjustment 2. R,G,B PRE AMP DC Confirmation 3. R,G,B PULCAN Adjustment 4. R,G,B PREPRO Level Confirmation 5. R,G,B PED TRACK Adjustment 6. Modulation Confirmation 7. R,G,B W/S (WHITE SHADING) OFFSET Adj. 8. Digital W/S (WHITE SHADING) Adjustment 9. Digital D/S (DARK SHADING) Adjustment 10. FLARE Adjustment 11. R,B GAMMA Adjustment
INF-24 11.DIAG-MENU Display 11-1-1. Version Display Operation Procedure (CAMERA Part) 1. Open the “ENG menu” (Press “MENU Button” more than 3 second.) 2. Open “CAM MAIN MENU 4 ” page (Press JOG Dial) 3. Select “DIAGNOSTIC” page (Turn and Press JOG Dial), then the Software version for each item can be comfirmed. 11-1-2. How to read the Version Display 11-2-1. Version Display Operation and Hour Meter Display (VTR Part) 1. Open the “ENG menu” (Press “MENU Button” more than 3 second.) 2. Press “MENU Button” again to open the “VTR MAIN MENU”. 3. Select “DIAGNOSTICS” page (Turn and Press JOG Dial), then the Software version for each item can be comfirmed. 11-2-2. How to read the Version Display T : 59.94Hz E : 59.94Hz/50Hz P : 50Hz Ver T1.00-01-1.00 Software Version ®< DIAGNOSTIC > CAMSOFT (IN) Ver T1.00-01-1.00 CAMSOFT (OUT) Ver T1.00-01-1.00 GAMMA GAIN Ver T1.00-01-1.00 GAMMA RAM Ver T1.00-01-1.00 KNEE Ver T1.00-01-1.00 ALC Ver T1.00-01-1.00 PLD Ver T1.00-01-1.00 Flash memory (Included IC1) Software Version Flash Memory (IC2) Software Version GAMMA Table Software Version Black GAMMA Table Software Version KNEE Table software Version ALC Software Version PLD Software Version ®< DIAGNOSTIC > OPERATION 99999X10h DRUM RUNNING 99999X10h THREADING 99999 VTR SYSCON n1.00-01-1.00 SERVO n1.00 MECHACON n1.00 FRONT n1.00-01-1.00 Operation Hour (: 10HOUR x) Cylinder Moter running Hour (: 10HOUR x) Loading, Unloading Times VTR SYSCON FLASH memory Software Version SERVO ROM MECHANISM CONTROL ROM AUDIO LCD ROM n1.00-01-1.00 n :NTSC p :PAL Brank : NTSC/PALSoftware Version
INF-25 11-2-3. How to Reset Hour Meter 1. Open the “Design Menu” and then press “MENU Button”. 2. Open “VTR DESIGN MENU ” page. (Press JOG Dial) 3. Select “VTR DESIGN MENU” item. (Turn & press JOG Dial) 4. After the following figure is displayed, move “®” to the item to reset. **** VTR DESIGN MENU **** ®VTR DESIGN MENU TEST MDOE ERROR LOG VM PLD V0.00 VTR SYSCON V18388a 00.06.13 MENU ALL INIT ®DRUM RUNNING RESET THREADING RESET
INF-26 12. Error Rate Display and Confirmation Method 12-1. Error Rate Display Method 1. Open the “VTR SERVICE MENU”. 2. Select “VTR SERVICE 1/3 ” page.(Turn & press JOG Dial) 3. Confirm “BER SPEED ” setting is “SLOW ”. 4. Select BER ADJ by rotating JOG Dial and Select R/P head to be confirmed. BER ADJ item :OFF / L1L3 / R1R3 / L2L4 / R2R4 (exept OFF) 5. The Error rate will be displayed in the Audio meter on the Audio LCD panel. - ¥ ¥¥ ¥ - - 40 - dB - 30 - - 20 - - 10 -- 0 - AUDIO LCD METER Error rate Spec. ”A ” CH1 CH2 L1 R1 L2 R2L3 R4 L3 R4
INF-27 13. Internal Switch Setting Method The switche settings on each circuit board are shown below. “Factory use only” switches must be set to the “Factory setting”. BOARD Ref. No. SWFACTORY SETTINGFEATURE AUDIO LCD 1-7 ON (FIXED) Factory use onlySW 40001 8 ON Not used 1-5 OFF(FIXED) Factory use onlySW 40002 6 OFF ON : ENG SEQURITY ON 1 ON Factory use only 2 OFF Factory use only 3 ON Factory use onlySW 47001 4 OFF Factory use only SW 41001 - -60 REAR CH1 MIC input level setting (-60dBu / -40dBu) SW 42001 - -60 REAR CH2 MIC input level setting (-60dBu / -40dBu) SW 41002 - -40 FRONT CH1 MIC input level setting (-50dBu / -40dBu) SW 42002 - -40 FRONT CH2 MIC input level setting (-50dBu / -40dBu) VTR SYSCON 1 OFF (FIXED) Not used 2 OFF EE-ROM write protect (allow is ON side)SW 500 3-4 OFF (FIXED) Factory use only 1 OFF (FIXED) Not used 2OFFEE-PROM initialize 1. Turn Off the unit 2. Switch SW201-2 and SW500-2 to ON ® Turn On the unit. 3. After 5 second, initialization is completed ® Turn Off the unit. 3 OFF (FIXED) Factory use only SW 501 4 OFF (FIXED) Factory use only AUDIO LCD board SW2001 SW7001 SW1001 SW2002 SW1002 SW40001 SW40002 VTR SYSCON board SW501 SW500
INF-28 14. Circuit board layout E5. CAMERA MOTHER P.C.BOARD E37. HD SDI TX P.C.BOARDE10. VTR SYSCON P.C.BOARDE36. VIDEO MAIN P.C.BOARDE14. RF EQ P.C.BOARD E19. POWER SW P.C.BOARD E24. MENU SW P.C.BOARD E20. TOGGLE SW P.C.BOARD E23. USER SW P.C.BOARD E21. MONITOR SW P.C.BOARD E22. SYNCHRO SW P.C.BOARD E17. AUDIO LCD P.C.BOARD E16. POWER SUB P.C.BOARD E15. POWER MAIN P.C.BOARD E27. EXT DC P.C.BOARD E26. HEAD PHONE P.C.BOARD E40. SDI BNC P.C.BOARD E18. REAR JACK P.C.BOARD E32. OPERAT E P.C.BOARDE38. BACK TALLY P.C.BOARD E39. SIDE BNC P.C.BOARD E30. REAR SW P.C.BOARD E31. CUE P.C.BOARD E7-1. DSP MAIN P.C.BOARD E2. TG P.C.BOARD E1. PRE AMP P.C.BOARD E7-2. MEMORY P.C.BOARD E25. CCD SENSOR P.C.BOARD E3. DRIVE P.C.BOARD E34. SD CARD P.C.BOARD E28. FRONT TOGGLE P.C.BOARD E29. JOG MENU P.C.BOARD E33. FRONT MIC P.C.BOARDE4. PRE PROCESS P.C.BOARDE6. CAMERA SYSCON P.C.BOARDE8. VIDEO OUT P.C.BOARD E13. HEAD BUFF P.C.BOARD E12. SERVO P.C.BOARD E11. SERVO FLEX P.C.BOARD E9. VTR MOTHER P.C.BOARD