Page 141
Private networking using PRI SL-1 / 141 P0992638 03Modular ICS 6. 0 Installer Guide The diagram below shows how TAT reduces the line requirements. The solid line shows Telephone A calling Telephone B and being transferred over an additional PRI line to Telephone C. With TAT active, the same call is transferred to Telephone C over the same PRI line. Call paths with and without TAT MCDN voice mail/auto attendant call features Besides the general MCDN features described in MCDN trunk call features on...
Page 142
142 / Private networking using PRI SL-1 Modular ICS 6.0 Installer GuideP0992638 03 To all Norstar systems on the private network, the centralized voice mail system is viewed as an external call by each system, even though the dialing plan configurations makes it seem like callers are making local calls. Camp-on A call received by the Meridian attendant can be assigned to a telephone anywhere in the MCDN network, when the following situations are valid: the target telephone rings busy when the...
Page 143
Private networking using PRI SL-1 / 143 P0992638 03Modular ICS 6. 0 Installer Guide Camping a call on a network telephone Break-in The Meridian attendant can break into an on-going call from a telephone in the Norstar system, if these situations are valid: Target Norstar telephone is busy but still has a free intercom or line key. DND busy is turned on, although the attendant can override a busy signal, if it is turned off, by pressing the BKI key. Prime set also should be busy, with no free key,...
Page 144
144 / Private networking using PRI SL-1 Modular ICS 6.0 Installer GuideP0992638 03 The diagram below demonstrates the call path for a Meridian attendant to break into a call between telephones in the Norstar system. Breaking into a Norstar call path Break-in can be accomplished using two methods: Pre-dial BKI: 1. Attendant presses BKI button on telephone. 2. Attendant dials the destination number. 3. On receiving a busy signal, the Attendant presses BKI again. The attendant is given access to the...
Page 145
Private networking using PRI SL-1 / 145 P0992638 03Modular ICS 6. 0 Installer Guide You can set a level of priority that will determine if a telephone will allow an attendant to break in. This is referred to as setting the Intrusion level. How the intrusion hierarchy works: Break-in allowed if Attendant telephone is High and caller telephone is Medium. Break-in is not allowed if Attendant telephone is Medium and caller telephone is high. Set the Intrusion level for each telephone under...
Page 146
146 / Private networking using PRI SL-1 Modular ICS 6.0 Installer Guide P0992638 03 Central voice mail and Auto Attendant with Norstar You can use Norstar voice mail (NVM) and Auto Attendant running on a Norstar Application module (NAM) platform as the central voice mail/auto attendant node for your MCDN network. However, this configuration does not allow centralized camp-on or break-in, since these are Meridian- voice-mail-based features. Using NVM requires that all nodes on the network are set up...
Page 147
Private networking using PRI SL-1 / 147 P0992638 03Modular ICS 6. 0 Installer Guide Local system To set up the local system, you need to assign a target line to the DN for the voice mail system, then enter that DN into the target line record. 1. After you enter your password, at the Terminals&Sets prompt, press ≠. The prompt displays: Show set: 2. Enter the DN number for the voice mail system. 3. Press ≠. The prompt displays Line access. 4. Press ≠. The prompt displays Line assignment. 5. Enter the...
Page 148
148 / Private networking using PRI SL-1 Modular ICS 6.0 Installer GuideP0992638 03 Remote system On the nodes that are not directly connected to the central voice mail system, you need to use the Telco Features headings to identify the route to the voice mail system. 1. After you enter your password, press ‘ until the prompt displays Telco Features: 2. Press ≠. The prompt displays VMsg Center tel#s. 3. Press ≠. The prompt displays VMsg Center 1. 4. Press ≠. The prompt displays Use:. 5. Press CHANGE...
Page 149
Private networking using PRI SL-1 / 149 P0992638 03Modular ICS 6. 0 Installer Guide 10. Press ‘ until the prompt displays Extl VMsg set. 11. Press CHANGE to select Y (yes). Set Telco features for the target line 1. Press “ until you reach the top level, then press ‘ until the prompt displays Lines. 2. Press ≠. The prompt displays: Show line: 3. Enter the target line number for the voice mail system. 4. Press ≠. The prompt displays: Trunk/line data: 5. Press ‘ until the prompt displays Telco...
Page 150
150 / Private networking using PRI SL-1 Modular ICS 6.0 Installer GuideP0992638 03 Note: Meridian mail and Norstar voice mail can co-exist on the same Meridian, however, users can only be configured for one of the systems. Configuring Centralized Auto Attendant (CAA) System configuration for centralized Auto Attendant depends on where the NAM is connected. The system with the NAM is configured using the CAA DN and a target line. The systems that are remote to the NAM are configured through the...