Page 11
Getting NVM-2 Up and Running Issue 1-0 Getting NVM-2 Up and Running u u 7 STEP 4 Install NVM-2 and Batteries Read the instructions next to Ê Ê below, then look for Ê Ê on Figure 3. Repeat for step 2. Ê Plug the NVM-2 power supply cord into the connector labeled “18VAC.” Place the adapter box into a 120V, 60 Hz grounded outlet. Ë Install (or replace) the batteries as follows: WARNING: Without batteries, NVM-2 will lose its messages and programming if there is a power failure. Without...
Page 12
Getting NVM-2 Up and Running Issue 1-0 Getting NVM-2 Up and Running u u 8 STEP 5 Connect NVM-2 to You Phone System Instructions for Installing a Portrait Phone System: Read the instructions next to Í Í below and look for Í Í on Figure 4. Repeat for step 5. ¹ Plug one end of a modular line cord into Voice Mail Port 1 on NVM-2. Plug the other end into an RJ14 to RJ11 adapter or RJ 14 jack. Plug the adapter into the Voice Mail Interface Unit using another 4-wire modular line cord. The...
Page 13
Getting NVM-2 Up and Running Issue 1-0 Getting NVM-2 Up and Running u u 9 STEP 5 Connect NVM-2 to You Phone System (cont’d) Instructions for Installing a 124i, VS or DS01 Phone System: Read the instructions next to Í Í below and look for Í Í on Figure 5. Repeat for Î Î. ¹ Plug one end of a modular line cord into Voice Mail Port 1 on the NVM-2. Plug the other end into an RJ14 to RJ11 adapter or RJ 14 jack. Plug L1 (or RD/GR pair) into a port on the phone system. º Repeat Í for...
Page 14
Getting NVM-2 Up and Running Issue 1-0 Getting NVM-2 Up and Running u u 10 STEP 6 Program NVM-2 for the Correct Phone System You have to set up the NVM-2 so that it recognizes the phone system you installed. The default phone system that is installed is the Portrait. To change this phone system: Set Security Code for System Administrator (extension 10) You must set a security code for extension 10 before you can change the phone system that is installed. To set the security code for...
Page 15
Getting NVM-2 Up and Running Issue 1-0 Getting NVM-2 Up and Running u u 11 Forwarding Extensions to NVM-2 NVM-2 uses unsupervised transfers with the Portrait Phone System. This means that extension users must forward their calls to NVM-2 in order for outside callers to leave a messa ge. Forwarding to NVM-2 is required so that an outside caller reaches the user’s mailbox after hearing the main greeting or after directlycalling an extension that is busy, in Do Not Disturb or does not answer....
Page 16
Getting NVM-2 Up and Running Issue 1-0 Getting NVM-2 Up and Running u u 12 Integrating the 124i with NVM-2 General Programming „0401 - Tenant Group Options, Part A, Item 18: SLT Answering Mode Enter 1 for this option to enable Conversation Record „ 0401 - Tenant Group Options, Part A, Item 23: DIL Call Waiting If setting up Immediate Voice Mail Overflow, enter 0. If setting up Delayed Voice Mail Overflow, enter 1. „0405 – System Timers (Part A), Item 10: Intercom Interdigit Time...
Page 17
Getting NVM-2 Up and Running Issue 1-0 Getting NVM-2 Up and Running u u 13 „0917 – DIL Assignment Assign a Voice Mail port as the DIL destination for each trunk that should directly ring into Voice Mail. If all Voice Mail ports are in the same unique Extension (Department) Group (see Program 1003 below), the DIL will ring another Voice Mail port if its assigned port is busy. „ 0919 – DIL No Answer Destination For Delayed Voice Mail Overflow, enter the Ring Group that unanswered DILs...
Page 18
Getting NVM-2 Up and Running Issue 1-0 Getting NVM-2 Up and Running u u 14 Integrating VS or DS01 with NVM-2 Terminal Programming: E – Extension Setup „E2 – Circuit Type Assign a circuit type 51 to each VX port. „ E5 – Hunt Type Program each VX port with Hunt Type 06. „ EA – Master Extension Number (for UCD Hunt Group) Program each VX port with the Master Extension Number assigned in QP programming (next page). „ EK – Voice Mail (VX) Port Enable this option for each VX...
Page 19
Getting NVM-2 Up and Running Issue 1-0 Getting NVM-2 Up and Running u u 15 Terminal Programming: Q – System Parameters „QP – Mailbox Installed Enable this option. This lets the phone system know that the Voice Mail is connected to it. „ QP – VX Master Extension Select one of the VX ports (from E2) as the VX Master Extension Number. Telephone Programming These are the programs to use if you are going to program the VS or DS01 through an extension in the telephone system. Use...
Page 20
Getting NVM-2 Up and Running Issue 1-0 Getting NVM-2 Up and Running u u 16 STEP 8 Set NVM-2 Time and Date To set the NVM-2 time and date from the System Administrator Mailbox (which is the lowest numbered extension): 1. From your Portrait extension: Press SPK, press ICM, dial NVM-2 Direct Lo g-On Number (98) (or press Mailbox Logon key). From your 124i extension: Press Voice Mail key. (Or, press CALL key, dial *8. On Sin gle Lines: dial *8). From your VS/DS01: Press Intercom key, press...