Page 31
Setting Up a Link Between IDEAand NVM-Series30uSetting Up a Link Between IDEA and NVM-SeriesChapter 2 uIssue 1-0Loading the COM Port Setup Data (contÕd) To load the setup data: 1. Start up IDEA (see Chapter 1). Get to the Main Menu. 2. Select Setup,then Load Setup Data. You see the menu below: 3. Select the desired file. nIf you select Default Data Fileor Internal Default Data,IDEA loads the file and returns you to the Main Menu. nIf you selectNamed Data File,IDEA shows you a list of all valid choices....
Page 32
Setting Up a Link Between IDEAand NVM-Series Issue 1-0uChapter 2Setting Up a Link Between IDEA and NVM-Series u31Establishing a Communications Link After the COM port parameters have been set up and the physical connec- tions have been made, you can establish a communications link between IDEA and NVM-Series (or any other RS-232 device). If necessary, you can connect to one device on the TERMINAL port (directly or via a modem) and another on the MODEM port.To establish a link between IDEA and NVM-Series...
Page 33
Setting Up a Link Between IDEAand NVM-Series32uSetting Up a Link Between IDEA and NVM-SeriesChapter 2 uIssue 1-0Establishing a Communications Link (contÕd) 4. Establish a link using a, b, or c below. Once you establish a link on the TERMINAL port, you can press Alt-X to exit terminal emulation mode, then establish a link on the MODEM port (or vice versa). To alternate between the links, press Alt + X.a.To set up a local (direct) link on the TERMINAL port: nFrom the IDEA Main Menu: Select Connect....
Page 34
Setting Up a Link Between IDEAand NVM-Series Issue 1-0uChapter 2Setting Up a Link Between IDEA and NVM-Series u33Establishing a Communications Link (contÕd) 4.b .(contÕd) nPress ENTER to verify that the NVM-Series system is respond- ing to the IDEA keyboard. A menu prompt should appear. To now use the IDEA MLV functions, see Accessing the MLV Functions later in this chapter. OR Press ENTER to verify that the RS-232 device is responding to the IDEA keyboard. c.To set up a modem link using the MODEM...
Page 35
Setting Up a Link Between IDEAand NVM-Series34uSetting Up a Link Between IDEA and NVM-SeriesChapter 2 uIssue 1-0Hanging up the Modem To hang up the modem when controlling it manually through the TERMINAL port:nWhile connected to the modem, type its hang-up command (e.g., the hang-up command for a Hayes-type modem is ATH).To hang up the modem when using IDEAÕs Automated Modem con- trol on the MODEM port:nFROM the IDEA Main Menu: Select Connect, then Hang Up Modem. OR From the IDEA Main Menu: Select...
Page 36
Setting Up a Link Between IDEAand NVM-Series Issue 1-0uChapter 2Setting Up a Link Between IDEA and NVM-Series u35Accessing the Memory Load/Verify (MLV) Functions After you establish a communications link between IDEA and the NVM- Series system, you can access the MLV functions. The MLV functions let you do the following: nSave (Backup), Restore, and/or Verify the NVM-Series database nArchive and/or De-Archive the NVM-Series database nUpgrade the NVM-Series software nModify the IDEA password Accessing...
Page 37
Setting Up a Link Between IDEAand NVM-Series36uSetting Up a Link Between IDEA and NVM-SeriesChapter 2 uIssue 1-0Accessing the Memory Load/Verify (MLV) Functions (contÕd) nPress Y. This suspends (but does not shut down) the NVM-Series system. If any NVM-Series ports are busy at this point, NVM-Series will ask you if you want to wait (W) until all ports are idle or abort (A), which returns you to the MAINTENANCE Menu. If you press W, NVM-Series will wait 15 seconds then check again for port activ- ity....
Page 38
Setting Up a Link Between IDEAand NVM-Series Issue 1-0uChapter 2Setting Up a Link Between IDEA and NVM-Series u37Accessing the Memory Load/Verify (MLV) Functions (contÕd) 3. Select the desired MLV Function as follows: nSelectMLV, then Easy Mode. You see the menu below. The highlight is on Password. nPress ENTER . nType the Level 1 or Level 2 password, then press ENTER . (This shuts down NVM-Series.) - Default Level 1 password is CTLINC. It provides access to the following MLV functions: Save,...
Page 39
Setting Up a Link Between IDEAand NVM-Series38uSetting Up a Link Between IDEA and NVM-SeriesChapter 2 uIssue 1-0Accessing the Memory Load/Verify (MLV) Functions (contÕd) 4. Wait for the modified MLV Menu (shown below): 5. Select the desired command. For details on the commands, see Chapter 3. Exiting MLV (Restarting NVM-Series) Exiting the MLV mode restarts NVM-Series.To exit MLV mode:nSelect Exit MLV. You return to the IDEA Main Menu. Exit MLV Save Restore Verify Archive De-Archive Upgrade Password...
Page 40
Issue 1-0uChapter 3Working With the NVM-Series Databaseu39 Chapter 3 Working With the NVM-Series DatabaseUsing and/or Modifying the Password . . . . . . . . . . . . . . . .41 Saving the NVM-Series Database to the IDEA Computer43 Verifying the NVM-Series Backup . . . . . . . . . . . . . . . . . .45 Restoring the NVM-Series Database . . . . . . . . . . . . . . . . .46 Archiving the NVM-Series Database to the NVM-Series Computer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48...