Page 521
2. PCB Installation 2-9 CONNECTING BLOCKS WHT-BLU BLU-WHT WHT-ORN ORN-WHT WHT-GRN GRN-WHT WHT-BRN BRN-WHT WHT-SLT SLT-WHT RED-BLU BLU-RED RED-ORN ORN-RED RED-GRN GRN-RED RED-BRN BRN-RED RED-SLT SLT-RED BLK-BLU BLU-BLK BLK-ORN ORN-BLK BLK-GRN GRN-BLK BLK-BRN BRN-BLK BLK-SLT SLT-BLK YEL-BLLU BLU-YEL YEL-ORN ORN-YEL YEL-GRN GRN-YEL YEL-BRN BRN-YEL YEL-SLT SLT-YEL VIO-BLU BLU-VIO VIO-ORN ORN-VIO VIO-GRN GRN-VIO VIO-BRN BRN-VIO VIO-SLT SLT-VIO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25...
Page 522
2-10 CONNECTING BLOCKS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 501 T 1 R 2 T 2 R 3 T 3 R 4 T 4 R 5 T 5 R 6 T 6 R 7 T 7 R 8 T 8 R 9 T 9 R 10 T 10 R 11 T 11 R 12 T 12 R 13 T 13 R 14 T 14 R 15 T 15 R 16 T 16 R WHT-BLU BLU-WHT WHT-ORN ORN-WHT WHT-GRN GRN-WHT WHT-BRN BRN-WHT WHT-SLT SLT-WHT RED-BLU BLU-RED RED-ORN ORN-RED RED-GRN GRN-RED RED-BRN BRN-RED RED-SLT SLT-RED BLK-BLU...
Page 523
2. PCB Installation 2-11 CONNECTING BLOCKS 80000 - 33 Figure 2-13 SECURING THE CABLESFigure 2-14 INSTALLING THE RFI SUPPRESSOR 80000 - 35 !! Install RFI Suppressor Assemblies as shown below !! You must install separate RFI Suppressor Assemblies for the ground wire, the CPU connections (i.e., mod jack and RS-232 cables), each trunk cable and each station cable. The suppres- sors mustbe mounted inside the cabinet and as close to the appropriate PCB as possible.
Page 524
2-12 CONNECTING BLOCKS Figure 2-15 8-PIN (RJ61X) JACK PINOUTS RJ61X Pin Latch faces upTo CPU Mod Jack Note reversalPort DesignationTo 66 Block WHT-BLU (1T) BLU-WHT (1R) WHT-ORN (2T) ORN-WHT (2R) WHT-GRN (3T) GRN-WHT (3R) WHT-BRN (4T) BRN-WHT (4R) 80000 - 18C 4T 3T 2T 1R 1T 2R 3R 4R 1 2 3 4 5 6 7 8 The following products should help if you make your own cables:Suttle SE-266-8K 8 Position Modular Plug (requires an SE-166 or SE-166-6 modular crimping tool).Hubbell BRFTP4P Snap-On 8 Position Modular Plug...
Page 525
In this section . . . Page Connecting Extensions . . . . . . . . . . . . . . . .3-2 Connecting Extensions . . . . . . . . . . . . . . . . . . 3-2 Connecting Trunks . . . . . . . . . . . . . . . . . . .3-3 Connecting Analog Trunks . . . . . . . . . . . . . . . 3-3 Power Up and System LEDs . . . . . . . . . . .3-4 Power Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 Finishing the Installation . . . . . . . . . . . . . .3-6 Reinstalling the Side Panel . . . . . . . . . . . . . . . 3-6...
Page 526
3-2 CONNECTING EXTENSIONS Connecting Extensions (Figure 3-1) Each 16DSTU PCB connects 16 digital extensions. Each 8ASTU PCB connects 8 analog extensions. Each 4ASTU PCB connects 4 analog extensions. 1. Using Figure 2-11 as a guide, insert the mod jacks into the appropriate connector on the PCB. 2. Install a modular jack for each extension within 6 feet of the telephone’s location. 3. For each extension, run one-pair 24 AWG station cable from the cross-connect block to the modular jack. 4. Terminate the...
Page 527
3. Installing Extensions and Trunks 3-3 CONNECTING TRUNKS Connecting Analog Trunks (Figure 3-2) Each 8ATRU PCB connects 8 loop start CO trunks. 1. Using Figure 2-12 as a guide, insert the mod jacks into the appropriate connector on the PCB. 2. For each trunk, run one pair cross-connect wire between the pins on the cross-connect block and the CPE (customer side) of the telco’s RJ21X. 3. Install bridging clips as required. Figure 3-2 CONNECTING ANALOG TRUNKS 25-Pair Cable to Central Office 25-Pair...
Page 528
3-4 POWER UP AND SYSTEM LEDS Power-Up (Figures 3-3 to 3-5) Now that all the PCBs you need are installed and you have cabled the system, you can now power-up. You do not need to reattach the right side panel before powering up the system. Leaving the right side panel removed makes the station and trunk cabling more accessible.To power up the system: 1. Make sure the system is properly grounded and the PCB bracket is reinstalled and secured. 2. Install surge protectors in the AC outlet you intend to use...
Page 529
3. Installing Extensions and Trunks 3-5 POWER UP AND SYSTEM LEDS PC A Major Alarm (Red) On: Major alarm present Off: Major alarm not present ➠ indicates the LEDs normal (i.e., system OK) status.➠ ➠ ➠ Minor Alarm (Red) On: Minor alarm present Off: Minor alarm not present ➠ RS-232 Port (Yellow) Flashing: RS-232 port active Off: RS-232 idle ➠ PC Card (Red) Flashing:PC card write/read active Off: PC card idle 3-4 CPU STATUS LEDS Port Activity (Yellow) Off: All ports on PCB idle. Flash: Port(s) busy....
Page 530
3-6 FINISHING THE INSTALLATION Reinstalling the Side Panel (Figure 3-6) To reinstall the side panel: 1. Carefully realign the right side panel and slide it into position. 2. Reattach the two screws that secure the right side panel to the cabinet. Figure 3-6 REINSTALLING THE SIDE PANELS 80000 - 16 A