Page 181
157 ❚❚The U Button When K (Choose color temp. ) is selected, the U button can be used to select the color temperature, although only for the amber (A)–blue (B) axis. Press the U button and rotate the sub- command dial until the desired value is displayed in the control panel (adjustments are made in mireds; 0154). To enter a color temperature directly, press the U button and press 4 or 2 to highlight a digit and press 1 or 3 to change. U button Sub-command dial Control panel
Page 182
158 Preset manual is used to record and recall custom white balance settings for shooting under mixed lighting or to compensate for light sources with a strong color cast. The camera can store up to six values for preset manual white balance in presets d-1 through d-6. Two methods are available for setting preset manual white balance: Preset Manual MethodDescription Direct measurement Neutral gray or white ob ject is placed under lighting that will be used in final photo and white balance is...
Page 183
159 Viewfinder Photography 1Light a reference object. Place a neutral gray or white object under the lighting that will be used in the final photograph. In studio settings, a standard gray panel can be used as a reference object. Note that exposure is automatically increased by 1 EV when measuring white balance; in exposure mode h, adjust exposure so that the exposure indicator shows ±0 ( 0122). 2Set white balance to L (Preset manual ). Press the U button and rotate the main command dial until...
Page 184
160 3Select a preset. Press the U button and rotate the sub-command dial until the desired white balance preset (d-1 to d-6) is displayed in the control panel. 4Select direct measurement mode. Release the U button briefly and then press the button until the L icon in the control panel starts to flash. A flashing D will also appear in the viewfinder. The displays will flash for about six seconds. U button Sub-command dialControl panel Control panel Viewfinder
Page 185
161 5Measure white balance. Before the indicators stop flashing, frame the reference object so that it fills the viewfinder and press the shutter-release button all the way down. The camera will measure a value for white balance and store it in the preset selected in Step 3. No photograph will be recorded; white balance can be measured accurately even when the camera is not in focus. 6Check the results. If the camera was able to measure a value for white balance, C will flash in the control...
Page 186
162 DDirect Measurement Mode If no operations are performed du ring viewfinder photography while the displays are flashing, direct measurement mode will end in the time selected for Custom Setting c2 ( Standby timer, 0 319). AProtected Presets If the current preset is protected ( 0169), 3 will flash in the control panel and viewfinder if you attempt to measure a new value. ASelecting a Preset Selecting Preset manual for the White balance option in the shooting menu displays the dialog shown at...
Page 187
163 Live View (Spot White Balance) In live view photography and movie live view (035, 49), white balance can be measured in a selected area of the frame, eliminating the need to prepare a reference object or change lenses during telephoto photography. 1Press the a button. The mirror will be raised and the view through the lens will be displayed in the camera monitor. 2Set white balance to L (Preset manual). Press the U button and rotate the main command dial until L is displayed in the control...
Page 188
164 3Select a preset. Press the U button and rotate the sub-command dial until the desired white balance preset (d-1 to d-6) is displayed in the control panel. 4Select direct measurement mode. Release the U button briefly and then press the button until the L icon in the control panel starts to flash. A spot white balance target ( r ) will be displayed at the selected focus point. 5Position the target over a white or grey area. While L flashes in the display, use the multi selector to...
Page 189
165 6Measure white balance. Press the center of the multi selector or press the shutter-release button all the way down to measure white balance. The time available to measure white balance is that selected for Custom Setting c4 ( Monitor off delay )> Live view ( 0 320). If the camera is unable to measure white balance, the message shown at right will be displayed. Choose a new white balance target and repeat the process from Step 5. 7Exit direct measurement mode. Press the U button to...
Page 190
166 AMeasuring Preset Manual White Balance (Live View) Preset manual white balance can not be measured when Record movies is selected for Custom Setting g4 ( Assign shutter button, 0 364) and the live view selector is rotated to 1. Preset manual white balance can not be set while an HDR exposure is in progress ( 0184) or when a setting other than None is selected for photo live view display white balance (monitor hue; 043).