Home > NEC > Communications System > NEC Server Installation Guide

NEC Server Installation Guide

Here you can view all the pages of manual NEC Server Installation Guide. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 11

NDA-30009   Revision 3.0Page 5
Server Installation Guide Application Configuration
Step  3:  Facilities (Messenger and Logical Monitor only)
According to instructions in the APM Operations Manual, designate the following 
NEAX2400 facilities for each Messenger and Logical Monitor component using 
the Facilities command on the APM Configuration Entry screen.  You only need 
to specify those facilities whose corresponding Server commands will be used.  For 
example, if you only use commands 10 to 17, you...

Page 12

Page 6NDA-30009   Revision 3.0
Application Configuration Server Installation Guide
Parameter Definitions:
Timeout Value #1:  Designates the number of seconds that Server is to wait for 
NTF/KTF input (default, if not specified in a command).  Applies to the 
Messenger only.
Tenant Number:  Specifies the number of the tenant that this Messenger and 
Logical Monitor each serves.  0=everyone.
Source Link Name:  Identifies the port on the source side of the communication 
link; entry should correspond to...

Page 13

NDA-30009   Revision 3.0Page 7
Server Installation Guide Application Configuration
Controller User-defined Parameters
Note:
An application can create a command file containing a sequence of commands 
that Server reads and executes, or it can exchange messages interactively with 
Server through a command FIFO.  If the application interacts with Server,  it 
sends to Server through a command
 FIFO and receives from Server through 
a response
 FIFO.  These are configured with the User-defined Parameters....

Page 14

Page 8NDA-30009   Revision 3.0
Application Configuration Server Installation Guide
This Page Left Blank. 

Page 15

NDA-30009   Revision 3.0Page 9
Server Installation Guide MAT Assignments
Chapter 3 MAT Assignments
This guide assumes that data settings that affect the operation of all OAI software 
on a system-wide basis have already been assigned on the NEAX Maintenance 
Administration Terminal (MAT).   Such settings include, system index values and 
assignment of Interface I/O Port Data in the Interface Processor (IP).  For more 
information about these system data settings and the MAT commands described 
below for...

Page 16

Page 10NDA-30009   Revision 3.0
MAT Assignments Server Installation Guide
The MSF/TMF facility and its Op-Code are assigned to one of the 14 OAI Key 
Codes in the MAT.  (The MSF Op-Codes range from 128 to 191 and TMF from 
192 to 255; assignments are available for on-screen viewing through the Providers 
command in the APM Application Configuration option.)   Each of the OAI Key 
Codes corresponds to an AKYD Function Key Index (FKI) value which is then 
assigned to the specific D
term function key.  This...

Page 17

NDA-30009   Revision 3.0Page 11
Server Installation Guide MAT Assignments
AKYD:  Assignment of Dterm Function Key
The AKYD command (formerly AKY1) can only be used to assign key data on 
those Dterms that have already been assigned through the ASDT command.
MAT Function Key Indexes #34 to #47 have been designated for use in the OAI 
system and correspond to the 14 OAI Key Codes as illustrated above.  The AKYD 
command is used to assign a D
term function key to the specific MAT Function Key 
Index that,...

Page 18

Page 12NDA-30009   Revision 3.0
MAT Assignments Server Installation Guide
Key Transfer Facility (KTF)
Activities needing KTF as an input device require MAT commands AKYD and 
AOKC for the assignment of the KTF op-code to a particular function key on 
specified D
terms.  Refer to the descriptions above for the MSF and TMF.
Restriction Control Facility(RCF)
When Server uses RCF, it specifies RSC and SFC values that have been defined 
through the following MAT commands:
ARSC:  Assignment of Route...

Page 19

NDA-30009   Revision 3.0Page 13
Server Installation Guide MAT Assignments
Status Monitor Facility – Request (SMFR)
If Server is to support an application that requires a monitored (sometimes called 
pilot) number, use MAT command AMNO to establish the monitored number, as 
follows:
AMNO:  Assignment of Monitored Number
Assigns a virtual station number as a monitored number that is controlled by 
Server.  Enter the same tenant number (except 0) configured for Server, the 
monitored number that Server will...

Page 20

MAT Assignments Server Installation Guide
Page 14NDA-30009   Revision 3.0
This Page Left Blank. 
Start reading NEC Server Installation Guide

Related Manuals for NEC Server Installation Guide