Home > NEC > Communications System > NEC Server Installation Guide

NEC Server Installation Guide

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Server Installation Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							SERVER
    INSTALLATION GUIDE
    NEC America, Inc.
    NDA-30009-003
    Revision 3.0
    December, 1996
    Stock # 241764 
    						
    							LIABILITY DISCLAIMER
    NEC America reserves the right to change the specifications,  functions, 
    or features in this document at any time without notice.  NEC America 
    has prepared this document for use by its employees and customers.  The 
    information contained herein is the property of NEC  America and shall 
    not be reproduced without prior written approval from NEC America.
    Copyright 1996
    NEC America, Inc. 
    						
    							NDA-30009  Revision 3.0Page i
    Server Installation Guide CONTENTS
    TABLE OF CONTENTS
    Page
    Chapter 1:  Introduction  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
    Chapter 2:  Application Configuration   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
    Step 1:  Application Characteristics (All Components)   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3
    Step  2:  Primary Configuration Parameters (All Components)  . . . . . . . . . . . . . . . . . . . . . . . . . . .  4
    Step  3:  Facilities (Messenger and Logical Monitor only)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5
    Step 4:  Secondary OAI Configuration Parameters (Messenger and Logical Monitor only)   . . . . .  5
    Step 5:  User-defined Parameters (All Components) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  6
    Chapter 3:  MAT Assignments  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
    Mode Set Facility (MSF) And Terminal Multi-Transfer Facility (TMF)   . . . . . . . . . . . . . . . . . . . . . .  9
    AOKC:  Assignment of OAI  Key Codes   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  10
    AKYD:  Assignment of Dterm Function Key  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  10
    Key Transfer Facility (KTF)   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12
    Restriction Control Facility(RCF)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12
    ARSC:  Assignment of Route Restriction Class  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12
    ASFC:  Assignment of Service Feature Class  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12
    ASDT:  Assignment of Station Data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12
    Switch Control Facility(SCF)   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12
    AADT:  Assignment of Announcement or Dictation Trunk  . . . . . . . . . . . . . . . . . . . . . . . . . . .  12
    Status Monitor Facility – Request (SMFR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  13
    AMNO:  Assignment of Monitored Number   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  13
    Chapter 4:  Initialization and Termination   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
    Initialization   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  15
    Termination   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  15 
    						
    							Page iiNDA-30009  Revision 3.0
    CONTENTS Server Installation Guide
    This Page Left Blank. 
    						
    							NDA-30009  Revision 3.0Page iii
    Server Installation GuideFIGURES
    LIST OF FIGURES
    Figure TitlePage
    Figure 3-1 OAI Function Key Assignment  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  10
    Figure 3-2 OAI Function Key Assignment Example   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11 
    						
    							Page ivNDA-30009  Revision 3.0
    FIGURESServer Installation Guide
    This Page Left Blank. 
    						
    							NDA-30009   Revision 3.0Page 1
    Server Installation Guide Introduction
    Chapter 1 Introduction
    This guide provides specific field entries that need to be made in the process of 
    installing and configuring Server.  In addition to this guide, use the following 
    manuals for this installation:
    •Applications Manager (APM) Installation Manual  – Contains step-by-step 
    instructions for installing the software from the release media.
    Applications Manager (APM) Operations Manual – Explains how 
    applications like Server are configured in the APM environment, using the 
    entries and values provided in this guide.
    NEAX2400 System Manuals – Give very detailed explanations about the 
    assignments that need to be made through the Maintenance Administration 
    Terminal (MAT) commands on the NEAX2400.
    Briefly, the installation and set up of Server involves the following processes:
    Software Installation – Server software must first be loaded from the release 
    media.  Log in to the APM Platform Management Menu, select the Installation 
    of Applications/Packages option, and follow the instructions provided in the 
    APM Installation Manual to complete this part of the installation.        
    Application Configuration – Server is internally supported by the APM and 
    must be configured in the APM environment.  This section provides the 
    information that must be entered into this APM configuration file.  Use the 
    instructions provided in the APM Operations Manual for the entries provided 
    in this section.
    MAT Assignments – Data settings that must be assigned at the NEAX 
    Maintenance Administration Terminal (MAT) depend upon the needs of the 
    application that Server is to support.  This section discusses some of the 
    relationships between the NEAX facilities that the application may require and 
    the MAT commands that frequently correspond to those facility functions.  Use 
    the instructions provided in the NEAX2400IMS System Manuals for any 
    required MAT command assignments. 
    						
    							Page 2NDA-30009   Revision 3.0
    Introduction Server Installation Guide
    The installation process and a list of reference manuals are shown in the diagram 
    below:
    Step 1:
    Software Installation
    Software Release Media
    Step 2:
    Application Configuration
    Application Characteristics
    Primary Parameter Configuration
    OAI Facilities (Optional)
    OAI Configuration Parameters (Optional)
    User-Defined Parameters
    Step 3:
    NEAX2400 IMS
    Maintenance Administration
    Terminal (MAT) Assignments
    Illustrated Relationships Between 
    NEAX2400 Facilities and NEAX2400 MAT Commands.SERVER INSTALLATION
    Introduction
    MAT Assignments Application ConfigurationDiscussed in chapter:
    Instructions in:
    APM Installation
    Manual
    NEAX2400 IMS
    System Manuals APM Operations
    Manual 
    						
    							NDA-30009   Revision 3.0Page 3
    Server Installation Guide Application Configuration
    Chapter 2 Application Configuration
    Server is configured into the APM system using the Add function of the 
    Application Configuration option on the APM System Administration menu.
    Enter the APM option from the APM Platform Management Menu.
    Enter the System Administrator password at the APM password screen.
    Enter the Application Configuration option from the System Administration 
    menu.
    This section contains the information that should be entered to the configuration 
    file for Server.  For specific instructions on what these parameters mean and how 
    to make these entries, refer to the APM Operations Manual.
    The following components must be configured for Server:
    The Command Controller, the background process that manages Server 
    functionality.
    Each Facility Messenger supported by Server.  There must be one per PBX 
    served.
    The Logical Monitor for each Facility Messenger.  The Logical Monitor 
    component is only required if Server commands #60 and #61 are used.
    Note:Fully configure one component at a time (steps 1-5), rather than attempting to 
    configure all components at each step.
    Step 1:  Application Characteristics (All Components)
    In this step, each component is characterized.   This characterization determines 
    what other parameters must be configured for the component.  Characterize each 
    component as follows:
    Parame te rFacility 
    MessengerCommand
    ControllerLogical
    MonitorDescription
    OAI Application (Y,N) Y N Y Indicates whether or not (Yes or No) 
    this component communicates with the 
    NEAX2400 using OAI processes.
    CRT Application 
    (Y,N)N N N Indicates whether or not (Yes or No) 
    this component requires a terminal 
    screen that is of the same type as the 
    one used by the APM.
    Communication 
    Queue (Y,N)N Y N Indicates whether or not (Yes or No) 
    this non-OAI application needs an IPC 
    queue to communicate with other 
    processes. 
    						
    							Page 4NDA-30009   Revision 3.0
    Application Configuration Server Installation Guide
    Step  2:  Primary Configuration Parameters (All Components)
    On the Configuration Entry screen, make the entries shown below to the 
    parameters indicated.  
    Note:
    It is assumed that the Facility Messengers are all configured alike except for their 
    names (e.g., Messenger 1, Messenger 2, etc.).
    Parameter Definitions:
    Application Name – Indicates the name to be displayed in the APM menus.
    Executable Filename – Contains the path name of the executable file.
    Group
     –
     Indicates the group to which the components are associated.
    Response Mode – Indicates the action that APM is to take with the component 
    should a member of the group terminate.
    Initialization Batch – Indicates whether or not the component is to be initialized 
    automatically when the OAI system is initialized.
    Termination Mode – Indicates how the APM is to tell the application to 
    terminate.
    Standard Output – Designates the file into which component output is 
    redirected.
    Number of Restarts – Indicates the number of times that the APM may restart 
    the component after it terminates erroneously.
    Queue Key – Indicates the queue key to be assigned to that component.
    Parame te rFacility 
    MessengerCommand
    ControllerLogical
    Monitor
    Application Name Messenger Controller Logmon
    Executable Filename /oai/app/svr/messenger /oai/app/svr/controller /oai/app/svr/logmon
    Group --- --- ---
    Response Mode I(gnore) I(gnore) I(gnore)
    Initialization Batch N(o) N(o) N(o)
    Termination Mode M(essage) M(essage) M(essage)
    Standard Output /oai/app/svr/msg.log /oai/app/svr/con.log /dev/null
    Number of Restarts 0 0 0
    Queue Key --- 200 --- 
    						
    All NEC manuals Comments (0)