    							INSTALLATION PROCEDURES
    NDA-30094 CHAPTER 2
    Page 73
    Revision 1 3.3.5 To Provide the Delay Announcement for ACD, when sending the delay announcement
    periodically or only once
    Command Description Data
    CM10Assign the Voice Recording Memory Card (PN-
    2DATA) to each LEN.(1) 0000~0511 (LEN No.)
    (2) EB000~EB127 (Voice Recording Memory 
    Card No.)
    CM20Assign an access code to record, replay, and delete 
    the Voice Recording card.Y=0-3
    (1) X-XXX Access Code
    A00: Record
    A01: Replay
    A02: Delete
    CM17Specify the pattern of the message sent to each 
    ACD group.Y=A
    (1) X~XXXX: Pilot Station number of the 
    ACD Group
    0: To be sent periodically
    1  : To be sent only once.
    CM41If the data for CM17, Y=A is “0,” set the interval 
    time of the ACD Delay Announcement.Y=0
    (1) FUNCTION No.:  47
    (2) 01~30 (12 sec.~134 sec.)
    If no data is set, the default 
    setting is 44~50 sec.
    Define the maximum waiting time of ACD call 
    for the ACD PEG Count. This timing is also ap-
    plied to the duration of Ringback Tone after a call 
    arrives.Y=0
    (1) FUNCTION No.:  16
    (2) 02~30 (8 sec.~120 sec.)
    If no data is set, the default 
    setting is 32~36 sec.
    CM49Assign the ACD Delay Announcement function 
    to the required Voice Recording Memory Card(s) 
    (PN-2DATA).YY=00
    (1) 000~127 (Voice Recording Memory 
    Card No.)
    (2) 0B0XX
    ACD Group No. (00~15)
    CM51When transferring the call to an extension or At-
    tendant after the first interval time of ACD Delay 
    Announcement, assign the destination
    Note:This command is effective when CM17,
    Y=A is set to 0 (set  periodically).Y=17
    (1) 00-63 : Tenant No.
    (2) Destination:
    X-XXXX:  Station No.
    E000: HA-610Z/SN610 ATTCON
    (2)
    (2) 
    						
    							CHAPTER 2 NDA-30094
    Page 74
    Revision 1
    INSTALLATION PROCEDURES
    3.3.6 To provide the Delay Announcement for ACD, when sending the ACD Second Delay
    Announcement
    Command Description Data
    CM49Assign the ACD Second Delay Announcement 
    function to the required Voice Recording Card(s) 
    (PN-2DATA).YY=00
    (1) 000-127 (Voice Recording Memory 
    Card No.)
    (2) 11XX
    ACD Group No. (00-15)
    CM08When a caller encounters all ACD/UCD stations 
    busy(1) 212
    (2) 0: Busy Tone Connection
    1 : Caller is placed into queuing 
    mode
    CM10Assign the Voice Recording Memory Card (PN-
    2DATA) to each LEN No.(1) 0000–0511 (LEN No.)
    (2) EB000–EB127 (Voice Recording Memory 
    Card No.)
    CM17Assign the pattern of the message to be sent to 
    each ACD group periodically.Y=A
    (1) X–XXXX:  Pilot Station number of the 
    ACD Group
    (2) 0: To be sent periodically
    CM41If the data for CM17, Y=A is “0”, set the interval 
    time of ACD Delay Announcement.Y=0
    (1) FUNCTION No.:   47
    (2) 01-30 (12 sec.-132 sec.)
    If no data is set, the default 
    setting is 44-48 sec.
    Define the maximum waiting time of ACD Call 
    for the ACD Delay Announcement.  This timing 
    is also applied to the duration of Ringback Tone 
    after a call arrives.Y=0
    (1) FUNCTION No.:   16
    (2) 01-30 (12 sec.-132 sec.)
    If no data is set, the default 
    setting is 44-48 sec. 
    						
    							INSTALLATION PROCEDURES
    NDA-30094 CHAPTER 2
    Page 75
    Revision 1 3.3.7 To monitor an ACD call, with or without Warning Tone
    Command Description Data
    CM08Specify the warning tone sent to connected parties 
    (in two-way calling) when monitoring.(1) 259
    0: No Tone
    1 : One Warning Tone
    CM12
    and
    CM15Assign the Class of Service for monitoring sta-
    tions.CM12, YY = 02
    (1) X~XXXX: Station number 
    (2) XXXX
     Service Restriction Class
      (A) (00-15 )
    CM15, YYY = 103
    (1) XX: Service Restriction Class (A) 
    00-15 assigned by CM12, 
    YY = 02
    (2)1 : Allowed
    CM12
    and
    CM15Assign the Class of Service for monitored sta-
    tions.
    Note:Monitoring telephone conversations
    may be illegal under certain circum-
    stances and laws.  Consult a legal advi-
    sor before implementing the monitoring
    of telephone conversations.  Some feder-
    al and state laws require a party moni-
    toring a telephone conversation to use
    beep-tone(s), to notify all parties to the
    telephone conversation, and/or obtain
    consent from all parties to the telephone
    conversation.  Some of these laws pro-
    vide strict penalties for illegal monitor-
    ing of telephone conversations.CM12, YY = 02
    (1) X~XXXX: Station number 
    (2) XXXX
      Service Restriction Class (A) 
    (00-15 )
    CM15, YYY = 104
    (1) XX: Service Restriction Class (A) 
    100-15 assigned by CM12, 
    YY = 02
    (2)1 : Allowed
    CM20Assign the access code for monitoring (if re-
    quired).Y=0-3 (Number Plan Group 0-3)
    (1) X-XXX: Access Code
    (2) 033: Monitor
    CM90Assign monitoring function key to the required 
    multiline terminals (if required).YY= 00
    (1) X-XXX: (Primary Ext. No.) +   
    + Key No. (01-16)
    (2) F0033: Monitor(2)
    , 
    						
    							CHAPTER 2 NDA-30094
    Page 76
    Revision 1
    INSTALLATION PROCEDURES
    3.3.8 To provide the External Indicator for Overflowed ACD Call Waiting
    Command Description Data
    CM08Assign the incoming call to queuing mode when all 
    ACD stations are busy.(1) 212
    (2) 1 : Queuing
    CM42Specify the maximum number of queuing in each ACD 
    group for controlling external equipment interface  (PN-
    DK00).
    Note:Depending on the number of queuing station/
    trunk, the lamp indication pattern on external
    equipment is different, as shown in the table be-
    low::(1) 15
    (2)01-99 (Number of queuing 
    in each ACD group)
    If no data is set, the default setting is 01.
    CM10Assign the PN-DK00 Card to the required LEN. (1) LEN (0000~0511)
    (2) E800~E831 (PN-DK00 card No.)
    E800~E807: For PIM0
    E808~E815: For PIM1
    E816~E823: For PIM2
    E824~E831: For PIM3
    CM44Assign the function of ACD Overflow Indication to the 
    PN-DK00.(1) XXX
    Circuit No. (0_3)
    Card No. (00_31) 
    assigned by CM10, 
    E800~E831
    (2) 14XX
    ACD Group No. 
    (00_15) assigned by 
    CM17.
    CM59Specify the ACD Overflow Indicator indication pattern. (1) 00
    01: 30 IPM (1 sec. ON/OFF)
    02: 60 IPM (0.5 sec. ON/OFF)
    03: 120 IPM (0.25 sec. ON/OFF)
    07: Steadily On
    N = Number of queuing station/trunk   
    Conditions Lamp indication
    2nd Data = 01Lamp on, irrespective of number 
    of queuing station/ trunk.  (For the 
    indication pattern, see CM59.)
    N < 2nd Data
    (2nd Data 
    ≠ 01)Lamp off.
    2nd Data 
    ≤ N 
    (2nd Data 
    ≠ 01)Lamp on.  (For the indication pat-
    tern, see CM59.)
    (2) 
    						
    							INSTALLATION PROCEDURES
    NDA-30094 CHAPTER 2
    Page 77
    Revision 1
    For connecting the Indicator for ACD Call Waiting:  
    Figure 2-2  Indicator Connection for ACD Call Waiting
    –48 VExternal Indicator with Battery
    G PN-DK00
    MDF
    External Indicator without Battery
    G PN-DK00
    MDF
    + – 
    						
    							CHAPTER 2 NDA-30094
    Page 78
    Revision 1
    INSTALLATION PROCEDURES
    3.3.9 To provide the call waiting lamps on the Multiline Terminal for  ACD Call
    3.3.10 To provide DID incoming LDN display on Multiline Terminal
    Command Description Data
    CM08Assign the incoming call to queuing mode when all ACD 
    stations are busy.(1) 212
    (2) 1 : Queuing
    Specify the maximum number of queuing in each ACD 
    group for controlling the call waiting lamp of Multiline 
    Te r m i n a l .
    Note:
    Depending on the number of the queuing sta-
    tion/trunk, the lamp indication pattern on
    Multiline Terminal is different, as shown in
    the table below.
    (1) 15
    (2) 01-99 (Number of queuing 
    in each ACD group)
    If no data is set, the default setting is 01.
    CM90Assign the ACD Call Waiting Indication LED to the re-
    quired Multiline Terminal.YY=00
    (1) Primary Extension No. + 
     + Key No.
    F1280:  ACD Group 00
    ...
    ..
    ..
    F1295:  ACD Group 15
    Command Description Data
    CM35Assign DID incoming LDN display on Multiline Terminal.
    Note:When the 2nd Data is set to “1”, a Trunk ID num-
    ber assigned by CM30, YY=19 is displayed.YY=75 (DID incoming 
    LDN Display on 
    Multiline Terminal)
    (1) Trunk Route No. (00-63)(2)
    0: Available
    1  : Not available  Note
    N = Number of queuing station/trunk   
    Conditions Lamp indication
    2nd Data = 01Steady on red irrespective of num-
    ber of queuing station/trunk.
    1  
    ≤ N < 2nd Data
    (2nd Data 
    ≠ 01)Steady on red.
    2nd Data < N
    (2nd Data 
    ≠ 01)Flashing red.
    ,
    (2)
    (2) 
    						
    							INSTALLATION PROCEDURES
    NDA-30094 CHAPTER 2
    Page 79
    Revision 1 3.3.11 To provide DID Number Conversion for an ACD Group
    Command Description Data
    CM35Assign the data for DID to the Trunk Routes as-
    signed by CM30.YY=12 (Number of digit to be re-
    ceived)
    (1) Trunk Route No. (00-63)
    0: Available
    3 : 4 digits
    YY=18 (Received digit conversion)
    (1) Trunk Route No. (00-63)
    (2) 0: To be provided
    YY=78 (Digit conversion of leading 
    2-4 digits of DID incoming 
    LDN)
    (1) Trunk Route No. (00-63)
    (2) 0: Available
    CM76When CM35 YY=18 is set to “0” (Received Dig-
    its Conversion is to be provided), assign the data 
    for interpreting the digits received.
    Note:When the digit conversion of leading 2-4
    digits of DID incoming LDN is available
    (CM35, YY=78, Data=0), leading 2-4
    digits LDN should be assigned as the
    first data of CM76. (When the DID in-
    coming LDN is 1 digit, the digit conver-
    sion for only one digit is not available.Y=0 (Day Mode)
    Y=1 (Night Mode)
    (1) X–XXXX: Station Number received.
    X–XXXX: Station/Data Station Number 
    to be terminated.
    DXX: Change Terminating System 
    to:
    D01
    D13: TAS
    D04: DIT
    D14: HA-610Z/ SN610 AT-
    TCON
    D16: DISA
    D09: Automated Attendant 
    (PN-2DATA)
    (2)
    (2) 
    						
    							CHAPTER 2 NDA-30094
    Page 80
    Revision 1
    INSTALLATION PROCEDURES
    3.4 How to run the ACD-MIS 
    Note:The remaining steps refer to entering specific customer data and performing an initial check of the system’s
    operation.  
    Step 1. Enter the unrestricted default password mis (lower case letters).  The Main Menu will be displayed.
    Note:Steps 7, 8, and 9 are required for minimum system configuration.
    Step 2. Specify the required ACD Groups(s).  Do not enter more than 12 characters per Group Name.
    Step 3. Enter the required Station Details. Be sure that the correct assignment of extension (e.g., analog or
    digital) has been made.
    Step 4. Enter the required agent detail.
    Step 5. Enter the required ACD key detail. Be sure that the PABX assignment matches the ACD-MIS as-
    signment.
    Step 6. Configure the required Report Time Values.  
    Step 7. Configure any requirement for Storage Intervals. 
    Step 8. Format the correct date format.
    Step 9. Perform the required Report Configurations. 
    Step 10. Perform the required Report Group Configurations.
    Step 11. Set the requirements for Report Scheduler. 
    Step 12. Set the required Group Statistics Threshold. 
    Step 13. Set the required Agent Statistics Threshold. 
    Step 14. Program the required passwords and their individual access arrangements.  Include the new name
    for the default password “mis” (where specified), and the altered access status of the default pass-
    word ENTER key.
    Step 15. Allow a suitable time for collection of preliminary data, then verify the recording of statistics.
      
    3.5 Hardware Required
    To provide the delay announcement for ACD:  PN-2DATA card
    To provide the Indicator for Overflowed ACD Call Waiting: PN-DK00 Card X 1
    External Indicator (visual or audible type) provided by the customer. 
    						
    							INSTALLATION PROCEDURES
    NDA-30094 CHAPTER 2
    Page 81
    Revision 1
    4. TROUBLESHOOTING
    4.1 General
    This section explains the troubleshooting information to be used after installing the ACD-MIS system.
    4.2 Troubleshooting Procedures
    Note:   See NEAX2000 IVS System manual for troubleshooting on TCP/IP link.
    Table 2-1  Troubleshooting Procedures
    Trouble Cause Action
    (1) Entering a password has no 
    effect.Improper password. Reenter correct password.
    (2) In Statistics Monitor Mode, 
    an extension does not appear 
    for a group.The PC does not expect messages for these 
    extensions.Make sure that all assignments in the station 
    configuration are equipped for the exten-
    sions to be reported.
    (3) Wall Boards cause improper 
    operation or lock up.Stargate Driver version 2.0 Obtain version 1.0 or 4.0 drivers. 
    						
    							CHAPTER 2 NDA-30094
    Page 82
    Revision 1
    INSTALLATION PROCEDURES
    5. EXTERNAL DISPLAY UNIT (EDU) SET-UP
    The following instructions refer to the EDU/PC hardware (Figures 2-3 through 2-4) and software aspects only.
    Programming of the customer specifications is done in conjunction with the MIS Set-Up procedures.
    5.1 RS-232C Board (DIGI PC/X) Installation
    Install the RS-232C driver board according to the DIGI PC/X board installation manual. 
    						