Page 171

NEAX2400 IMX CCIS Features and Specifications
Page 156NDA-24222, Issue 3
M-67 Message Center Interface - CCIS
Service Conditions (cont’d)
 AUTOMATIC RECALL [A-8]
 Call Return from Hold 
 Operator Call
 LDN Call
Feature 2:
 Station dials Message Center Number Directory.
 Direct Trunk Call to Message Center.
 Trunk Call to Message Center extended by ATTENDANT
 Station Call is FORWARDED-ALL CALLS to Message Center.
 Trunk Call is FORWARDED-ALL CALLS to Message Center.
 Station Call is...

Page 172

NEAX2400 IMX CCIS Features and Specifications
NDA-24222, Issue 3
Page 157
Night Connection - Fixed - CCIS N-15
N-15  Night Connection - Fixed - CCIS 
General Description
When the Night mode has been entered, this service feature routes calls, normally directed to the ATTENDANT
CONSOLE [A-3], to a preselected station in another node through CCIS.
Operating Procedure
1. The Night lamp illuminates, when the Attendant in Node A sets Night mode with the NITE key pressed.
2. An incoming call from the CO RT to...

Page 173

NEAX2400 IMX CCIS Features and Specifications
Page 158NDA-24222, Issue 3
N-15 Night Connection - Fixed - CCIS
Operating Procedure (cont’d)
3. Station C answers and is connected with the CO RT. If necessary, the call can be transferred to another
station by means of Call Transfer-All Calls service.
Service Conditions
1. Calls that are being processed, or are in the Hold state when the NIGHT mode is entered, will be
disconnected after the mode changeover has been completed. 
2. If the NIGHT CONNECTION...

Page 174

NEAX2400 IMX CCIS Features and Specifications
NDA-24222, Issue 3
Page 159
Night Connection - Flexible - CCIS N-16
N-16  Night Connection - Flexible - CCIS
General Description
This feature provides inter-office flexible Night Connection service through the CCIS network, when the NIGHT
CONNECTION-FIXED - CCIS and NIGHT CONNECTION-FLEXIBLE - CCIS stations are located in different
nodes.
Operating Procedure
To set NIGHT CONNECTION-FLEXIBLE - CCIS:
1. The NIGHT CONNECTION-FIXED - CCIS station in the...

Page 175

NEAX2400 IMX CCIS Features and Specifications
Page 160NDA-24222, Issue 3
N-37 Name Display - System - CCIS
N-37 Name Display - System - CCIS
General Description
In between CCIS networks, this service allows calling or called party information (user’s name, telephone number,
etc.) to be displayed on the LCD of the Dterm.
Operating Procedure
No manual operation is required.
Service Conditions
1. When the called party is being rung, the LCD of the calling Dterm displays the name of the called party.
2. When...

Page 176

NEAX2400 IMX CCIS Features and Specifications
NDA-24222, Issue 3
Page 161
Name Display - System - CCIS N-37
Service Conditions (cont’d)
11. When a call has been transferred by Call Forwarding-All Outside Line Calls or Call Forwarding-Busy
Outside Line service, the LCD of the calling party’s Dterm displays the name information of the transfer
destination instead of the name information of the originally dialed station.
12. This service cannot be used in conjunction with ISDN Information Transfer - CCIS...

Page 177

NEAX2400 IMX CCIS Features and Specifications
Page 162NDA-24222, Issue 3
N-46 Number Portability - CCIS
N-46 Number Portability - CCIS
           (Series 7400 software feature)
General Description
This feature allows telephone number data in an FCCS group (a network where multiple NEAX2400 IMXs are
connected via FCCS link) to be carried to another FCCS group. This feature also allows telephone number data to
be carried in a NEAX2000 IVS via CCIS link. This feature is available by simple command operation...

Page 178

NEAX2400 IMX CCIS Features and Specifications
NDA-24222, Issue 3
Page 163
Number Portability - CCIS N-46
Service Conditions (cont’d)
Legend:
* Destination node
** Node to be connected to the FCCS group where the new number is added
*** Node where the telephone number is located before the Number Portability activation
No.Pattern (telephone number is moved from A to B)Node Requiring Data Change
1. Moving number within the same FCCS group. NCN in Center FCCS group
2. Moving number in FCCS group to another...

Page 179

NEAX2400 IMX CCIS Features and Specifications
Page 164NDA-24222, Issue 3
O-11 Off-Hook Queuing - CCIS
O-11  Off-Hook Queuing - CCIS
General Description
This feature allows a user in a CCIS network to remain off-hook and automatically enter a first-in, first-out queue
at the calling and distant nodes when an all-trunk-busy condition has been encountered. As soon as an outgoing trunk
becomes available, the off-hook station is connected to that trunk through CCIS.
Operating Procedure
1. Dial the trunk...

Page 180

NEAX2400 IMX CCIS Features and Specifications
NDA-24222, Issue 3
Page 165
Off-Hook Queuing - CCIS O-11
Interactions (cont’d)
6. The following features cannot be activated toward the busy station:
CALL WAITING-ORIGINATING [C-31]
CALL WAITING-TERMINATING [C-12]
ATTENDANT CAMP-ON WITH TONE INDICATION [A-1, 45]
BUSY VERIFICATION [B-3, 9]
EXECUTIVE RIGHT-OF-WAY [E-1, 8]
7. To disable constant service set tone, change ASYD System Data 1, Index 42 Bit 7 to data “1”. This
changes constant service set tone to...