Page 31
English-29 EnglishREMOTE CONTROL ID FUNCTION REMOTE CONTROL ID The remote control can be used to control up to 100 individual MultiSync\ monitors using what is called the REMOTE CONTROL ID mode. The REMOTE CONTROL ID mode works in conjunction with the Monitor ID, allowing control of up to 100 \ individual MultiSync monitors. For example: if there are many monitors being used in the same\ area, a remote control in normal mode would send signals to every monitor at the same t\ ime (see Figure 1)....
Page 32
English-30 3. Press the “DISPLAY” button on the remote control while aiming at the “PRIMARY” monitor. The Information OSD will be shown at top left side of the screen. Monitor ID: Displays the ID number of the current monitor within the daisy chain. Target ID: Displays the ID number of the monitor that to be controlled via daisy c\ hain from the current monitor. Press the “+” or “-” buttons to change the “Target ID” to show the ID number of the monitor to be controlled. To control the e ntire...
Page 33
English-31 EnglishThis LCD monitor can be controlled by connecting a personal computer wit\ h a RS-232C terminal. NOTE: When you use this function, EXTERNAL CONTROL should be “RS-232C” (See page 24). Functions that can be controlled by a personal computer are: Power ON or OFF Switching between input signals Connection LCD Monitor + PC RS-232C Cable PC (Out) RS-232C CableRS-232C (OUT) MultiSync RS-232C (IN) RS-232C (OUT) RS-232C (IN) IN OUT MultiSync MultiSync NOTE: If your PC is equipped only with...
Page 34
English-32 Connecting to a Network Using a LAN cable allows you to specify the Network Settings and the Alert Mail Settings by using an HTTP server function. NOTE: When you use this function, EXTERNAL CONTROL should be “LAN” (See page 24). To use a LAN connection, you are required to assign an IP address. Example of LAN connection: Server Hub NOTE: Use a category 5 or higher LAN cable. LAN cable (not supplied) Network Setting by Using an HTTP Browser Overview Connecting the monitor to a network allows...
Page 35
English-33 English Preparation Before Use Connect the monitor to a commercially available LAN cable before engagin\ g in browser operations. Operation with a browser that uses a proxy server may not be possible de\ pending on the type of proxy server and the setting method. Although the type of proxy server will be a factor, it is possible that items that have actually been set will not be displayed depending on the effectiveness of the cache, and the contents set from the browser may not \ be re...
Page 36
English-34 Alert Mail Setting http:///lancon g.html This option noti es your computer of an error message via e-mail when using wired LAN. An error message noti cation will be sent when an error occurs in the monitor. Alert Mail Checking [ENABLE] will turn on the Alert Mail feature.Checking [DISABLE] will turn off the Alert Mail feature. Host Name Type in the hostname of the network connected to the monitor. Up to 60 alphanumeric characters can be used. Domain Name Type in the domain name of the...
Page 37
English-35 English Alert error message list Error number* ErrorCode Alert mail Message Explanation Measure 70h ~ 7Fh The monitor’s power supply is not functioning normally. Standby power Abnormal Please contact your supplier. 80h ~ Fh The cooling fan has stopped. Cooling fan Abnormal Please contact your supplier. 90h ~ 9Fh The monitor’s back light unit is not functioning normally. Backlight abnormal Please contact your supplier. A0h ~ AFh The monitor is overheated. Temperature Abnormal Please...
Page 38
English-36 Reduced Footprint: Provides the ideal solution for environments with superior image quality\ . Color Control Systems: Allow you to adjust the colors on your screen and customize the color ac\ curacy of your monitor to a variety of standards. OmniColor: Combines Six-axis color control and the sRGB standard. Six-axis color c\ ontrol permits color adjustments via six axes (R, G, B, C, M and Y) rather than through the three axes (R, G and B) previously availab\ le. The sRGB standard provides...
Page 39
English-37 EnglishNo picture The signal cable should be completely connected to the display card/computer. The display card should be completely seated in its slot. Check the main Power Switch, it should be in the ON position. Front Power Switch and computer power switch should be in the ON position. Check to make sure that a supported mode has been selected on the display card or system being used. (Please consult display card or system manual to change graphics mode.) Check the monitor and...
Page 40
English-38 Specifi cations - V462 Product Specifi cations LCD Module Pixel Pitch: Resolution: Color: Brightness: Contrast Ratio: Viewing Angle: 46”/1168 mm diagonal 0.530 mm 1920 x 1080 Over 16 million colors (depending on video card used) 450 cd/m 2 (Max.), 340 cd/m2 (Factory setting Typ.) @25°C 3000:1 89° (typ) @ CR>10 Frequency Horizontal: Vertical:15.625/15.734 kHz, 31.5 kHz - 91.1 kHz (Analog Input) 31.5 kHz - 91.1 kHz (Digital Input) 50.0 - 85.0 Hz Pixel Clock 25.2 MHz - 162.0 MHz Viewable Size...