Page 31
NECA 340-414-100 Revision 2.0Page 19 MCU 5000A Multipoint Control Unit General Description Manual RS-422/HSD IF Unit 3.25 Four number of channels are accommodated in one RS-422/HSD IF unit which is normally used as LIF. The HSD interface is available with strap setting. (Refer to NECA 340-414-210.) The RS-422 IF unit, which does not support multiplexed signal as 1.5M LIF unit, accommodates only four channels. The system parameter setting is as follows: Line rate and logical line number (+30H...
Page 32
Page 20NECA 340-414-100 Revision 2.0 General Description Manual MCU 5000A Multipoint Control Unit Common Item for Each LIF Unit 3.27 The common setting items for each LIF unit are as follows. Clock source (+3BH): The clock source is specified in the following clock mode. • Automatically • External clock of physical line number (1 to 16) • Internal clock Clock source mask: The physical line required to mask can be specified by bit in automatic mode of clock source. I: Cascade- Connection3.28 When two...
Page 33
NECA 340-414-100 Revision 2.0Page 21 MCU 5000A Multipoint Control Unit General Description Manual Figure 3-6: Casade-Connection of Two MCU 5000A Figure 3-7: Two Groups Casade-Connection J: Console Through- Pass3.33 The MCU 5000A, which provides the three console ports, is simultaneously controlled from the three consoles connected using the console through-pass with CH2/CH3 of the MCU 5000A. The plural MCU 5000As (maximum 9) can be controlled by one console. Fig. 3-8 shows for through-pass...
Page 34
Page 22NECA 340-414-100 Revision 2.0 General Description Manual MCU 5000A Multipoint Control Unit K: Supplementary Functions3.35 The following supplementary functions are provided. Automatic Start Setting Function 3.36 The teleconference opening is normally performed by the command entering from the console, MCU simple control terminal, or the teleconference reservation system. The opening system with multipoint connection is particularly provided. Automatic Start Setting function is that the...
Page 35
NECA 340-4 14- 10 0 Revisio n 2.0 Page 23 MCU 5000A Multipoint Control U nit General Description Manual 4: HARD WAR E C ONFIGUR ATION LIN E DATA R R L 8 8 8 4 C PU BUS CPU B U S 8 8 88 HSD
Page 36
Page 24NECA 340-414-100 Revision 2.0 General Description Manual MCU 5000A Multipoint Control Unit A: 1.5M LIF Unit General 4.02 1.5M LIF unit receives AMI (B8ZS) signal from 1.544 Mbps transmission line, extracts the clock pulse with IPAT (PEB2235), converts bipolar signal to unipolar, and sends it to ACFA (PEB2035). ACFA detects frame synchronization and transmission line failure. ACFA converts incoming signal to standard signal (Octet pulse 8 kHz, 4 MHz clock) within the equipment by the...
Page 37
NECA 340-414-100 Revision 2.0Page 25 MCU 5000A Multipoint Control Unit General Description Manual Functional Block Diagram 4.05 Fig. 4-2 shows 1.5M LIF unit block diagram. Figure 4-2: Block Diagram of 1.5M LIF Unit 1.5M LIF Unit Interface (1) Table 4-1 shows the electrical specification. This interface conforms to ITU-TS G.703, I.431. 1.544 Mbps LINE INF 1 1.544 Mbps LINE INF 2 1.544 Mbps LINE INF 3 1.544 Mbps LINE INF 4MULTICONFERENCE DATA BUS (LD S/R) POINT-TO-POINT CONFERENCE BUS (LB) IPAT...
Page 38
Page 26NECA 340-414-100 Revision 2.0 General Description Manual MCU 5000A Multipoint Control Unit (2) Table 4-2 and Fig. 4-3 shows 1.5M LIF Connector Pin Assignment -: Not Used Figure 4-3: 1.5M LIF (CH1 to CH16) Connector Pin Assignment Table 4-2: 1.5M LIF (CH1 to CH16) Signal Assignment PIN NO. SIGNAL NAME I /O REMARKS PIN NO. SIGNAL NAME I /O REMARKS 1 SHIELD Cable shield 9 T (B)+ OUT Transmitting Data (B) 2 T (A)- OUT Transmitting Data (A) 10 - 3 - 11 R (B)+ IN Receiving Data (B) 4 R (A)- IN...
Page 39
NECA 340-414-100 Revision 2.0Page 27 MCU 5000A Multipoint Control Unit General Description Manual Line Management 4.06 The MCU 5000A manages for line state according to the following Table 4-3. _: Not transit /: Not existed Fz: Transit to Fz state TABLE 4-3 Table 4-3: User Side Primary Tributary Rate Layer 1 Status Transition (Pick-up) INITIAL STATE F0 F1 F2 F3 F4 F5 STATE DEFINITIONOperation or Failure statePower OFF (user side)Active FC1 FC2 FC3 FC4 STATE DEFINITIONSignaling for InterfaceNo Data...
Page 40
Page 28NECA 340-414-100 Revision 2.0 General Description Manual MCU 5000A Multipoint Control Unit B: RS-422 LIF Unit General 4.07 The RS-422 Line Interface unit receives a signal with RS-422 level (corresponds to X.21) from a transmission line. After extracting the clock pulse, TTL level and bit rate within the equipment conversion is performed. The processed signal is detected H.221 frame synchronization, and then output to MTSC (PEB2045). 4.08 The MTSC arranges the outgoing lines (minimum 56...