NEC Infoset 408 System Manual
Here you can view all the pages of manual NEC Infoset 408 System Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 41
Issue 1AInfoSet 408 2 - 2Installation 1.2 Opening the KSU and Attaching the Batteries The two batteries, located in the lower left corner of the KSU, provide complete system backup power for approximately 30 minutes during power outages. This provides backup for the entire system (the key system and telephones) in case of a power outage. It is important that these be connected before the system is installed. 1. Remove the cover by loosening the two bottom screws with a Phillips head screwdriver (the...
Page 42
InfoSet 408Issue 1A System Manual2 - 3 3. Locate the lithium battery receptacle on the backplane of the KSU. Using the provided battery, place it at an angle and push downward and inward to install. The battery should slide into place. Figure 2-2 Attaching the Backup Battery Connectors Figure 2-3 Installing the Lithium Battery Connect Batteries to Battery Terminals on KSU Power Supply Lithium Battery Push downward and inward
Page 43
Issue 1AInfoSet 408 2 - 4Installation 4. Locate the battery memory switch in the upper left side of the KSU. Move the switch to the right toward the “HOLD” position. 5. Replace the cover and tighten the screws. 6. Turn the on/off switch on the KSU to the ON position. Figure 2-4 Setting the Battery Memory Switch Battery Memory Switch FLOW MEMORY HOLD CLEAR Slide the switch to the right toward the HOLD position. If you are wall mounting the KSU or want to install the speaker relay...
Page 44
InfoSet 408Issue 1A System Manual2 - 5 1.3 Wall Mounting the KSU A wall mounting template is provided with the KSU to help mark the position of the KSU on the wall. 1. Use the wall mounting template to mark the position of the KSU on the wall. Be sure to select a sturdy wall (not metal). 2. Insert two of the provided Phillips head wood screws into the wall. Leave about 1/2” of the screw extruding from the wall. 3. If the cover has been replaced, remove the KSU cover by loosening the two bottom screws...
Page 45
Issue 1AInfoSet 408 2 - 6Installation 6. Attach the cover and tighten the screws. 7. Using a standard RJ-11 cord (user-provided) attach the trunk lines (ports) into the RJ-11 jacks marked 1 and 2. This provides connection to the telephone service provider. 8. Using a standard RJ-11 cord (user-provided) connect the telephones into RJ-11 jacks marked 1~5. This connects your telephones to the system. 9. Plug the system into a standard wall outlet and turn the on/off switch on the KSU to...
Page 46
InfoSet 408Issue 1A System Manual2 - 7 1.4 Installing the External Speaker Relay Cable This cable allows you to connect a paging system with a power control function that requires a relay contact. The power ratings are: 24 Vdc. 1A or 120 Vac, 0.5A. 1. Be sure the system is turned off during the installation process. 2. Remove the KSU cover by loosening the two bottom screws with a Phillips head screwdriver (the screws remain in the cover to keep from misplacing them). Pull the cover away from the...
Page 47
Issue 1AInfoSet 408 2 - 8Installation 5. Locate the connector terminal labeled SP RLY on the KSU backplane. Insert the small white connector end of the speaker relay cable into the connector terminal on the backplane. Take the cables and wrap them around the terminal post to the right of the terminal connector. Figure 2-8 Attaching the Speaker Relay Cables Slide RJ-11 connector into slotWrap cable around terminal post
Page 48
InfoSet 408Issue 1A System Manual2 - 9 6. Attach the cover and tighten the screws. 7. Locate the RJ-11 jack (labeled SP RLY) located on the sideplane of the KSU. Attach one end of an RJ-11 cord (user-provided) into the jack and attach the other end into an paging control system (user-provided). 8. Turn the on/off switch on the KSU to the ON position. Figure 2-9 Inserting the Connector into the Terminal Figure 2-10 Inserting the Telephone Cord into the Jack Insert connector into connector...
Page 49
Issue 1AInfoSet 408 2 - 10Installation SECTION 2INSTALLING ELECTRONIC TELEPHONE UNITS Electronic Telephone Units (ETUs) can be installed at the same time that the KSU is initially installed or individually as needed. The instructions for each individual ETU assumes the unit is being installed at a later time, therefore, there are steps which will not apply (i.e., turning the KSU off/on and removing the cover). If installing the unit(s) at the same time as the KSU, ignore the steps that are not...
Page 50
InfoSet 408Issue 1A System Manual2 - 11 5. Using a Phillips head screwdriver, secure the ESI board to the KSU by tightening the screw. 6. Attach the cover and tighten the screws. 7. Using a standard RJ-11 cord (user-provided) connect the additional telephones into RJ-11 jacks marked 6~8. 8. Attach the other end of the RJ-11 cord into the telephones. 9. Turn the on/off switch on the KSU to the ON position. Figure 2-11 Installing the ESI ETU into the KSU Figure 2-12 Connecting the Telephones...