Home > NEC > Communications System > NEC Guardian An Open Application Interface Operations Manual

NEC Guardian An Open Application Interface Operations Manual

Here you can view all the pages of manual NEC Guardian An Open Application Interface Operations Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 21

NDA-30008   Revision 2.0Page 11
Guardian Operations Manual Installation Introduction
Application Configuration
Guardian is configured into the APM system using the Add function of the 
Application Configuration option on the APM System Administration menu.
1. Enter the APM option from the APM Platform Management Menu.
2. Enter the system administrator password at the APM password screen. 
3. Enter the Application Configuration option from the System Administration 
menu.
This section contains the...

Page 22

Page 12NDA-30008   Revision 2.0
Installation Introduction Guardian Operations Manual
Step 1: Application 
CharacteristicsIn adding Guardian to the APM Application Configuration file, define it as an OAI 
application that does not need a CRT or a communication queue, as follows:
Step 2: Primary 
Configuration 
ParametersOn the Configuration Entry screen, make the entries shown below to the 
parameters indicated:
Table 2-1  Application Characteristic Entries
Parameter Entry Description
OAI Application...

Page 23

NDA-30008   Revision 2.0Page 13
Guardian Operations Manual Installation Introduction
Step 3: OAI 
FacilitiesAccording to instructions in the APM Operations Manual, designate the following 
PBX facility for Guardian using the Facilities command on the Configuration 
Entry screen:
Authorization Code Facility (ACF)
Step 4: Secondary 
OAI Configuration 
ParametersUsing the OAI-Conf command on the Configuration Entry screen, make the entry 
shown for each of the following parameters required by Guardian. Use...

Page 24

Page 14NDA-30008   Revision 2.0
Installation Introduction Guardian Operations Manual
Step 5: User-
Defined 
ParametersMake the following additional parameter entries through the UserDefined 
command on the APM Configuration Entry screen.
Table 2-4  User-Defined Parameter Entries
Parameter Entry Description
User Defined #1 10 IO Delay Factor – The period of time in 
which Guardian collects a block of codes 
before recording them.
User Defined #2 5 IO Block Factor – The number of historical 
records...

Page 25

NDA-30008   Revision 2.0Page 15
Guardian Operations Manual Installation Introduction
This completes the configuration of Guardian in the APM. See “Database 
Requirements” on page 16. to create its databases.
User Defined #9 /oai/app/guard/ Base Directory – The path name, where 
binary files reside.
User Defined #10 /oai/db/cur/grdacf Authorization Code Database – The path 
name of the Authorization Code database.
User Defined #11 /oai/db/cur/grdgrpf Group Database – The path name of the 
Group database....

Page 26

Page 16NDA-30008   Revision 2.0
Installation Introduction Guardian Operations Manual
Database Requirements
Each configured Guardian tenant requires five working databases (Group, 
Authorization Code, Extension, Time Interval, and ID). Each database is created 
through the Database Administration option on the APM System Administration 
Menu. Database creation involves the following four-step process for each 
required database:
1.Create a Master Definition File: This step involves creating the master...

Page 27

NDA-30008   Revision 2.0Page 17
Guardian Operations Manual Installation Introduction
Group Database 
InformationThe Group database field entries are shown in the table below and defined in “Field 
Definitions” on page 17. Name the master definition file grdgrpf
_m and the 
application definition file grdgrpf.
Field Definitions
Group ID – A number that identifies a group, lying within the range from 1 to 
1000. This is the key field for database sorting, so entries must be arranged in 
ascending order....

Page 28

Page 18NDA-30008   Revision 2.0
Installation Introduction Guardian Operations Manual
Authorization 
Code and ID 
Database 
InformationThe Authorization Code master definition file and master database file support 
both the Authorization Code database and the ID database. Create separate 
Authorization Code and ID application definition files to process the master 
database into the two separate databases. Name the master definition file 
grdacf
_m, name the Authorization Code application definition file...

Page 29

NDA-30008   Revision 2.0Page 19
Guardian Operations Manual Installation Introduction
‡Use these values for the NEAX2000.
*The fields of the two application definition files (Authorization Code and ID) that 
are derived from the authorization code master database must be entered in the 
following sequence:
Order Authcode Definition File ID Definition File
#1 Authorization Code ID
#2 Interval Index Authorization Code
#3 Extension/Group Value
#4 Route Restriction Class
#5 Service Feature Class
#6 Extension...

Page 30

Page 20NDA-30008   Revision 2.0
Installation Introduction Guardian Operations Manual
Extension 
Database 
InformationThe Extension database field entries are shown in the table below and defined in 
“Field Definitions” on page 20. Name the Extension master definition file 
grdextf
_m and the application definition file grdextf.
Field Definitions
Extension No. – The extension number of up to 5-digits in length. This is the 
key field of the database, and entries must be arranged in ascending order....