Page 91
6. Specifications and Parts 6-1 Section 6, SPECIFICATIONS AND PARTS LIST In this section . . . PageSpecifications . . . . . . . . . . . . . . . . . . . . . . .6-2 Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . .6-6
Page 92
6-2 SPECIFICATIONS System Capacities Conference Circuits 32 Conference circuits dynamically allocated, with 8 parties max. per Conference. Conference circuits provided on CPU. 8ATRU Analog Trunk PCB:Refer to System Config- 4ATRU Analog Trunk PCB:uration - U Slot on page 16DSTU Digital Station PCB:1-15 and System Config- 8ASTU Analog Station PCB:uration - Fixed Slot on 4ASTU Analog Station PCB:page 1-18 for capacities. CPU Central Processing Unit: 1 REJ Recording Jack Units 1 max. per keyset System...
Page 93
6. Specifications and Parts 6-3 SPECIFICATIONS Electrical Specifications The following specifications apply to each power supply installed. Power Supply: 120 VAC ±- 10% @ 50-60 Hz Output Power 91 Watts @ 100% full load Input Current 1.50A @ 110 V VA 165 Kwh .165 BTU 563 Grounding Requirements: 12 AWG copper wire Environmental Specifications Cabinets and Key Telephones Temperature: 0-45 oC (32-113 oF) Humidity: 10-95% (non-condensing) Door Box Temperature: 0-45 oC (32-113 oF) Humidity: 10-95%...
Page 94
6-4 SPECIFICATIONS External Paging Output Impedance: 600 Ohm Output Level: 0 dBr at 1.0 KHz CPRU Relay Contacts Contact Configuration: Normally open Maximum Load: 60 mA @ 30 VDC 10 mA @ 90 VDC Maximum Initial Contact Resistance: 50 mOhms Mechanical Specifications Equipment Width Depth Height Weight 4-Slot KSU 10 3/4””5 7/8””13 11/16”4 lbs 5 oz 8-Slot KSU 19 1/2””5 7/8””13 11/16”6 lbs 12 oz Non-display Keyset 7 1/4”9”2 7/8””1 lb 11 oz Display Keyset 7 1/4”9”2 7/8”1 lb 12 oz Super Display Keyset 7 1/4”9”2...
Page 95
6. Specifications and Parts 6-5 SPECIFICATIONS Cabling Requirements 1. Do not run station cable parallel with the AC source, telex or com- puter, etc. If the cables are near cable runs to those devices, use shielded cable with grounded shields or install the cable in conduit. 2. When cables must be run on the floor, use cable protectors. 3. Cable runs for key telephones, single line telephones, and Door Boxes must be a dedicated, isolated cable pair.Device Cable Type Cable Run Length (ft) Notes Key...
Page 96
6-6 PARTS LIST Common Equipment Description Part Number 4-Slot KSU 80000 8-Slot KSU 80001 DS2000 Power Supply 80005 80005A Installation Cable 80892 Blank PC Card 85880 PC Card with system software preloaded 80051-V**.** (**.** denotes the system software level) 8-Pin DIN to Mod-8 Cable 80893 DB9 to Mod-8 Adaptor 85980 DB25 to Mod-8 Adaptor 85981 Spare KSU Hanger 80578 You must use an A version Power Supply in an 8 Slot Cabinet Peripheral Station Equipment Description Part Number 2-OPX Module 92177A...
Page 97
6. Specifications and Parts 6-7 PARTS LIST Replacement Parts Description Part Number Handset and Cord Assembly 80150 Noise Canceling Handset 80150NC Handset Coil Cord - Black 9’92297-9 Handset Coil Cord - Black 13’92297-13 Handset Coil Cord - Black 25’92297-25 Telephone Line Cord - Black 7”82476-7 Telephone Line Cord - Black 14”82476-14 34 Btn Super Display Tel Clear Plastic Cover 80600-S34 34 Btn Tel Clear Plastic Cover 80600-34 22 Btn Tel Clear Plastic Cover 80600-22 110-Button DSS Console Clear...
Page 99
Th 6-9 co NEC America, Inc., Corporate Networks Group 4 Forest Parkway, Shelton, CT 06484 Tel: 800-365-1928 Fax: 203-926-5458 cng.nec.comOther Important Telephone Numbers Sales: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .203-926-5450 Customer Service: . . . . . . . . . . . . . . . . . . . . . . . . . . .203-926-5444 Customer Service FAX: . . . . . . . . . . . . . . . . . . . . . . .203-926-5454 Technical Service: . . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 100
NEC America, Inc., Corporate Networks Group 4 Forest Parkway, Shelton, CT 06484 TEL: 203-926-5400 FAX: 203-929-0535 cng.nec.com