Home > NEC > Communications System > NEC Call Forward Control Installation And Operations Manual

NEC Call Forward Control Installation And Operations Manual

Here you can view all the pages of manual NEC Call Forward Control Installation And Operations Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 11

NDA-30030-003 Revision 3Page 1
Call Forward Control - Installation & Operations Manual INTRODUCTION
Chapter 1 INTRODUCTION
OVERVIEW
Call Forward Control (CFC) is an application suite that enhances the forwarding of 
incoming calls from both internal and external sources. The CFC programs use the 
Status Monitor, Switch Control, and Service Set facilities of the NEAX2400 IMS 
as accessed through the OAI. Telephones may be forwarded directly to an 
extension using the Hard Forward feature. Incoming calls...

Page 12

Page 2NDA-30030-003 Revision 3
INTRODUCTION Call Forward Control - Installation & Operations Manual
OVERVIEW (Cont)
The CFC Administration program is used to create and modify the telephone 
databases and event schedules used by the HFC and CFC applications. Telephone 
extensions can be grouped by common forwarding (HFC) and routing (CRC) 
patterns. This grouping feature makes it possible to forward and/or reroute whole 
departments at a time or different departments according to different schedules or...

Page 13

NDA-30030-003 Revision 3Page 3
Call Forward Control - Installation & Operations Manual INTRODUCTION
MANUAL  ORGANIZATION
Chapter 2
Chapter 2 of this manual provides detailed information to be used in the software 
installation and configuration of Call Forwarding Control.  The APM Operations 
Manual provides step-by-step instructions for entering the data that is presented in 
this chapter.
Chapter 3
This chapter describes the system of interrelated assignments that can be made 
through the CFC...

Page 14

Page 4NDA-30030-003 Revision 3
INTRODUCTION Call Forward Control - Installation & Operations Manual
SCREEN  
ILLUSTRATIONS 
(Cont)Heading or TitleA display of the CFC name and a date and time stamp that 
is periodically updated.
Main Working AreaThe area in which CFC menus are displayed, input is 
made to data entry prompts, and data is displayed for on-screen viewing.
Message / Command AreaThe bottom of the screen where instructions (e.g., 
Arrow keys to move cursor), commands (e.g., Add, Delete),...

Page 15

NDA-30030-003 Revision 3Page 5
Call Forward Control - Installation & Operations Manual INTRODUCTION
SCREEN  
ILLUSTRATIONS 
(Cont)Each Section Overview displays graphically the movement from the Main Menu 
to the next screen level (i.e., Screen (1) to screen (2)).  Thereafter, each subsection 
displays the movement from the second level screen to any third or fourth (i.e., 
Screen (2) to screen (3)).  This progression of screens and the progression of 
subsections by Main Menu options makes it easier to...

Page 16

Page 6NDA-30030-003 Revision 3
INTRODUCTION Call Forward Control - Installation & Operations Manual
GENERAL  KEY  
USAGE (Cont)Tab KeyPressed while in a field, displays information that corresponds to that field 
in other options.  The following notation is includes in the description wherever 
this key can be used.
REQUIREMENTSTwo groups of hardware are required for any OAI application:  the User 
Application Processor (UAP) and the Private Branch Exchange system (PBX). The 
minimum configuration for...

Page 17

NDA-30030-003   Revision 3Page 7
Call Forward Control - Installation & Operations Manual INSTALLATION INTRODUCTION
Chapter 2 INSTALLATION INTRODUCTION
This chapter provides specific field entries that need to be made during the 
installation and configuration of Call Forward Control.  In addition to this chapter, 
use instructions in the following manuals for this installation:
Applications Manager (APM) Installation Manual  – Contains step-by-step 
instructions for installing the software from the...

Page 18

Page 8NDA-30030-003   Revision 3
INSTALLATION INTRODUCTION Call Forward Control - Installation & Operations Manual
The installation process, including its description in this manual and other manuals 
that are necessary, is illustrated in Figure 2-1.
Figure 2-1   Installation Requirements
Initialization / Termination APM Operations
Manual NEAX 2400 IMS
Maintenance Administration
Terminal (MAT) Assignments
AMNO (Assignment of Monitored Numbers)
AKYI (Assignment of Dterm Function Keys)
NEAX 2400 IMS
System...

Page 19

NDA-30030-003   Revision 3Page 9
Call Forward Control - Installation & Operations Manual INSTALLATION INTRODUCTION
SOFTWARE INSTALLATION
Installation of CFC software is initiated from the Applications Manager (APM) 
Platform Administration Main Menu.  To display this menu, enter the login 
apmadm at the UNIX prompt and press ENTER.  Using instructions in the APM 
Operations Manual, select and implement the Installation of Applications/
Packages option from this menu to load CFC software from release...

Page 20

Page 10NDA-30030-003   Revision 3
INSTALLATION INTRODUCTION Call Forward Control - Installation & Operations Manual
SOFTWARE INSTALLATION (Cont)
STEP 3:   
Superuser (Root) Password
Type the correct password for the root login and press  to continue. An 
invalid password displays the message “Invalid root password. Do you wish to 
continue? (Y/N) [ ]”. Type y  to try again, or n  to cancel 
the installation.
STEP 4:   
MCS Enhancement or Independent APM Application
At this point in the installation, a...
Start reading NEC Call Forward Control Installation And Operations Manual

Related Manuals for NEC Call Forward Control Installation And Operations Manual

All NEC manuals