Page 61 7-4 Greasing the Pedal Assy Plunger 1. Remove 4off security screw (M5x12) and remove the switch cover plate. 2. Remove 2off whizztite nuts (M4) and remove the switch. 3. Remove 4off whizztite nuts (M4) and remove the plaunger assembly. Note: The plunger is spring loaded. Keep the plunger pressed in when removing the assy and release the plunger slowly. 4. Remove any old grease and dirt from the plunger and pedal plate. 5. Grease both the plate and spherical portion of the plunger. 6. Reassemble in reverse order.

Page 62 7-5 Replacing the Pedal Plunger 1. Remove the plunger assembly. (See 7-4 page 61) 2. Pull the plunger out of the holder. Replace with the new plunger. (The new plunger should have grease applied all over prior to fitting). 3. Wipe off any old grease and dirt from the pedal plate and regrease. 4. Reassemble in reverse order.

Page 63 7-6 Gun Assembly 7-6-1 Replacing the Gun Assembly 1. Remove 8off security screws (M8x20) and remove the gun pod complete with the gun. 2. Disconnect the connectors and remove the 2off whizztite nuts (M6). 3. Remove the gun assembly from the gun pod. Note: When replacing the gun assembly ensure that the earth wires are located on to the studs before fitting and tightening the whizztite nuts (M6)

Page 64 7-6-2 Removing the Gun Slide 1. Remove 4off cap screws (M3x10), 1off button screw (M4x25), and 1off hex nut (M4), and detach the gun slides (L) and (R). 2. Reassemble in reverse order.

Page 65 7-6-3 Removing the Gun Cover 1. Remove the gun slides (L) and (R). (See 7-6-2 page 64) 2. Place the gun (L) face down, and remove the 4off button screws (M4x10), 1off button screw (M4x25), 4off hex nuts (M4), and 1off c\ ap screw (M3x10). Remove the gun cover (R) taking care that the lens does not fall out. 3. Reassemble in reverse order. ( Ensure that the flat face of the lens is facing the back of the gun).

Page 66 7-6-4 Replacing the Solenoid 1. Remove the gun cover and gun slide (R). (See 7-6-2 page 64 and 7-6-3 page 65) 2. Disconnect the solenoid connector. 3. Remove 1off cap screw (M3x10) on the gun cover (L) and remove the solenoid bracket. 4. Remove 1off cup screw M (M3x8) and detach the earth wire. 5. Loosen the nuts (16mm dia.) and remove the solenoid. 6. Remove 2off cup screws M (M4x6) and detach the slide guide. 7. Pull out the solenoid plunger, taking care not to lose the spring. 8. Reassemble in reverse order. Note: When reassembling match the D-type hole of the solenoid bracket to the D shape of the solenoid and ensure that the ‘E’ rin\ gand spacers are in the correct positions.

Page 67 7-6- 5Replacing the Trigger Switch 1 . Remove the gun cover and gun slide (R). (See 7-6-2 page 64 and 7-6-3 page 65) 2. Replace the microswitch. Take care when replacing the switch that the correct wires are fitted to the correct terminals. 3. Reassemble in reverse order. 7-6-6 Replacing the Flexible Gun Conduit. 1. Remove the gun assembly. (See 7-6-1- page 63). 2. Remove the 2off security screws (M4x10), then detach the connector cover. 3 . Remove the gun cover and gun slide (R). (See 7-6-2 page 64 and 7-6-3 page 65). 4. Detach the solenoid bracket and detach the solenoid connectors and earth wire. (see 7-6-4 page 66). 5. Disconnect the sensor and detach the fast-on connectors from the micro switch. 6. Remove the button head screw (M4x10) fixing the conduit to the gun cover (L) and detach the conduit. 7. Reassemble in reverse order.

Page 69 m e t Ino i t p i r c s e DoN t r a P 2SV J - r o t i n o M n o i t c e j o r P 0 5 r e e n o i P0 0 0 0 0 0 4 8 3la c e D t n o r F ) S H L ( t e n i b a C r o t c e j o r P7 5 2 0 0 0 0 4 4la c e D t n o r F ) S H R ( t e n i b a C r o t c e j o r P5 8 2 0 0 0 0 4 6mm 5 7 - r o t s a C l e v i w S5 0 0 0 0 0 9 5 759 x 6 1 M - t o o F e l b a t s u j d A9 7 0 0 0 3 8 8 9el l i r G r e k a e p s d u o L s s a B8 2 8 0 0 0 6 4 0 143 0 1 M W S r e e n o i P - r e k a e p s d u o L s s a B5 1 1 - 6 0 0 X 1 1tr o P r e k a e p s d u o L s s a B7 3 8 0 0 0 6 4 2 1)S H R ( l a c e D e d i S t e n i b a C r o t c e j o r P3 5 2 0 0 0 0 4 3 1)S H L ( l a c e D e d i S t e n i b a C r o t c e j o r P7 5 2 0 0 0 0 4

Page 70 m e t Ino i t p i r c s e D.o N t r a P 1et a l P g n i s o l C r a e R r e d a e H6 6 8 0 0 0 6 4 2)S H L ( m r o F - c a V r e d a e H3 6 8 0 0 0 6 4 4te k c a r B g n i s o l C c i l y r c A r e d a e H0 4 8 0 0 0 6 4 5)S H R ( m r o F - c a V r e d a e H4 6 8 0 0 0 6 4 6hs e M r e k a e p s d u o L5 6 8 0 0 0 6 4 7ci l y r c A r e d a e H3 2 0 0 0 0 0 3 84 e b u t t n e c s e r o u l F9 3 0 0 0 5 4 6 94 y l b m e s s A t n e c s e r o u l F5 4 0 0 0 0 4 6 0 1tt a w 0 2 ½ 4 r e k a e p s d u o L6 0 0 0 0 0 2 6