Page 51

Page 51 4. Move both levers to the centre and press either the left or right start
button.
If initialization is successfull COMPLETED will be displayed.
5. Slide the TEST switch OFF to return to normal game mode.I/F INITIALIZE
DIP
12345678[ON:OFF]
MOVE BOTH JOYSTICKS LEFT,
THEN PRESS BUTTON.
[L] 0000 [R] 0000
MOVE BOTH JOYSTICKS RIGHT,
THEN PRESS BUTTON
[L] 0000 [R] 0000
MOVE BOTH JOYSTICKS CENTER,
THEN PRESS BUTTON
[L] 0000 [R] 0000
COMPLETED
EXIT
SELECT SW : CHOOSE
ENTER SW : ENTER 

Page 52

Page 52
8. MAINTENANCE
G GG G
GAdjustment or maintenance on this machine should be carried out by
qualified personnel only.
D DD D
DEinstellungen und Wartung des Gerätes dürfen nur von dafür
qualifiziertem Fachpersonal vorgenommen werden.
l ll l
lJusteringer eller vedligehold af denne maskine bør kun udføres af
kvalificeret personale.
E EE E
ELos ajustes y el mantenimiento de esta máquina deben ser realizados
sólo por personal cualificado.
F FF F
FL’installation, le service, le réglage, ou la maintenance...

Page 53

Page 53
8-1 Greasing the Swing Lever Springs
The Swing Lever Springs should be greased every 6 months.
1. Remove 9off security screws (M5x12) from the control panel cover.
2. Disconnect the connectors and remove the control panel cover.
3. Apply grease to the positions shown in the following diagram.
4. Reassemble in reverse order. 

Page 54

Page 54
8-2 Checking Swing Lever Absorber Rubbers
Check for wear every 3 months. 
1. Remove 9off security screws (M5x12) from the control panel cover.
2. Disconnect the connectors and remove the control panel cover. 
3. Check the absorber rubbers for wear or damage. 
4. Replace the rubber if worn or damaged. (see section  8-6 page  58) 

Page 55

Page 55 8-3 Replacing the Fluorescent Tube or Starter
1. Remove the 3off pozi head screw (M5x12) and remove  the top retaining
bracket.
2. Remove the Header Acrylic.
3. Replace the fluorescent tube or starter.
4. Reassemble in the reverse order. 

Page 56

Page 56
8-4 Replacing the Start Button or Lamp
1. Remove the control panel cover.  (see section 8-2 page 54)
2. Replace the micro switch. (
Note: When replacing the switch ensure that
the wires are replaced to the correct terminals).
3. Remove the lamp holder from the button assembly by pulling the lamp holder out.
4. Replace the lamp. 
5. To replace the button assy undo the retaining nut and withdraw the butto\
n assembly from the control panel cover. 

Page 57

Page 57
8-5 Replacing the Potentiometers
1. Remove the control panel cover  (see section 8-2 page 54).
2. Disconnect the potentiometer connector. 
3. Place the swing lever of the potentiometer to be replaced to the centre \
of the machine.
4. Slacken the grub screw (M4x8) and remove the potentiometer complete with mounting bracket.
5. Replace the potentiometer.
6. Reassemble in reverse order.
Note: When refitting the potentiometer ensure that the locating tab of the
potentiometer engages in the hole in...

Page 58

Page 58
8-6 Replacing the Swing Lever Absorber Rubbers
1. Remove the control panel cover.  (see section 8-2 page 54)
2. Remove the 2off socket head screws (M5x16) and remove the transparent cover.
3. Remove the 4off button head screws (M4x6) and remove the absorber rubber.
4. Replace the absorber rubber. 
5. Reassemble in reverse order 

Page 59

Page 59 8-7 Replacing the Side Covers
1. Remove the 2off pozi head screws (M4x10) with spring washers.
2. Replace the side covers.
3. Reassemble in reverse order. 

Page 60

Page 60
8-8 Replacing the Monitor
The monitor weighs approx 40kg. Ensure that at least two people are used\
 to 
remove the monitor, and there is sufficient space to work safely. 
1. Remove the control panel cover.  (see section 8-2 page 54)
2. Loosen the 2off lower security screws (M5x12), and remove the 4off upper security screws (M5x12), and remove the monitor maintenance 
panel from the rear of the cabinet.
3. Disconnect the monitor connectors. 
4. Remove the 4off hex head screws (M6x40), flat and...