    							Page 51 6-2-6 Sound Test
    1. Select “SOUND TEST” on the menu screen to check the sound and to adjust the
    volume. The following screen is displayed.
    2. Use the Select Up/Down switch to choose the required item, then press the Enter
    button.
    3. Use the Select Up/Down switch to change the setting.
    4. Press the Enter button to return to the select mode.
    5. Select “EXIT” and press the Enter button to return to the ‘Game Options’ screen.
    (a) Volume setting for sound during Play Mode. Settable between 000~127 with
    000the quietest and 127 the loudest. (default 80)
    (b) Volume setting for sound during Attract Mode. Settable between 000~127 with
    000the quietest and 127 the loudest. (default 70)
    (c) Sound level of non playing position during a single player game. Settable
    between 000~127 with 000the quietest and 127 the loudest. (default 40)
    (d) Each number will produce a different sound, (for approx. 10 seconds), when the
    Service button is pressed.
    001 when selected will produce a sound from the left speaker only, then the rigtht
    speaker only, and then both speakers together as a stereo check.
    (e) Displays details of the Song No.
     SOUND TEST
      [DEFAULT IN GREEN]
    VOLUME ALL SP  (O-127) 80
     ATTRACT (0-127) 70
     NO ENTRY (0-127) 40
    REQUEST SONG NO  000
    MESSAGE  
     EXIT
     SELECT SW : CHOOSE  ENTER SW : ENTER
    (a)
    (b)
    (c)
    (d)
    (e)
    * * * * * * 
    						
    							Page 52 6-2-7 ADS Data
    1. Select “ADS DATA” on the menu screen to view bookkeeping details. The
    following scren is displayed.
    2. Use the Select Up/Down switch to choose the required item, then press the Enter
    button.
    3. Select “EXIT” and press the Enter button to return to the Game Options Menu
    Screen.
    (a) Displays the total time the game has been switched on.
    (b) Displays the total time the game has been played.
    (c) Displays the length of the average playing time.
    (d) Displays the ratio between the total power on time and the total time the game
    has been played.
    (e) Displays the total number of games played.
    (f) This option allows the bookkeeping to be reset.
      ADS DATA [1/2]
    POWER ON TIME  12:34:56
    TOTAL PLAY TIME  23:45:01
    AVE. PLAY TIME  11:11:11
    AVE. PLAY RATIO  50.00%
    PLAY COUNT  120
     ADS DATA INITIALIZE
     EXIT
    SELECT SW : CHOOSE  ENTER SW : ENTER
    (a)
    (b)
    (c)
    (d)
    (e)
    (f) 
    						
    							Page 53 6-2-8 Others
    1. Select “OTHERS” on the m,enu scren to check the software version, set the on
    screen instruction language and reset all adjustments to factory default. The
    following screen is displayed.
    2. Use the Up/Down Select switch to choose the required item, then press the Enter
    button.
    3. Select “EXIT” and press the Enter button to return to the Game Options Menu
    Screen.
    (a) Displays the current software version.
    (b) Displays the PCB internal clock settings. (not used on this game)
    (c) Displays the PCB serial number.
    (e) Allows the display to be paused. When set to ON the display will pause each time
    the Select switch is pressed IP. Resume normal display by pressing the Select
    switch UP again. (No sound will be produced while the screen is paused)
    (f) For testing the Game PCB. (This function is only for factory testing)
    (g) When selected, the Data Initialization Menu appears. To reset all the game
    settings to factory default and clear all stored data select YES from the Data
    Initialization menu and press the Enter button.
    NOTE: The game 
    will not function correctly unless the software version is the
    same for both game PCBs.
     OTHERS
    ROM Ver.  2001/06/01  WED  12:34:56
    CLOCK  - - - -/ - - / - -  - - -   - -: - -: - -
    S/N  123456 - 123456
    LANGUAGE ENG
    PAUSE OFF
    NAOMI TEST MODE
    BACKUP MEMORY INITIALIZE
     EXIT
    SELECT SW : CHOOSE  ENTER SW : ENTER
    (a)
    (b)
    (c)
    (d)
    (e)
    (f)
    (g) 
    						
    							Page 54
    7. MAINTENANCE
      
    Adjustment or maintenance on this machine should be carried out by
    qualified personnel only.
    Ensure that the 
    POWER to the machine is turned OFF before commencing
    any maintenance work. (Trouble shooting, service or repairs etc.)
      
    Einstellungen und Wartung des Gerätes dürfen nur von dafür qualifiziertem
    Fachpersonal vorgenommen werden.
    Vor Beginn aller Wartungsarbeiten (Fehlersuche, Reparaturen etc.) muß der
    Netzstecker gezogen werden.
      
    Justeringer eller vedligehold af denne maskine bør kun udføres af
    kvalificeret personale.
    Sørg for, at strømmen til maskinen er slukket før der foretages nogen form
    for arbejde (fejlfinding, reparation etc.)
      
    Los ajustes y el mantenimiento de esta máquina deben ser realizados sólo
    por personal cualificado.
    Asegúrese de que la máquina está desconectada antes de comenzar
    cualquier trabajo de mantenimiento (reparaciones, resolución de
    problemas, etc.)
      
    L’installation, le service, le réglage, ou la maintenance doivent être
    effectués uniquement par les personnes qualifiées.
    S’assurer que l’interrupteur soit sor OFF avant de commencer tout travail
    de maintenance (localisation d’une panne, rèparations, etc.)
      
    Μετατρπές ή επιδιρθώσεις στα µηανήµατα πρέπει να γίννται µν απ
    ε)υσιδτηµένα άτµα.
    Να είναι σίγυρα κλειστ τ ρεύµα πριν πιαδήπτε δυλειά στ
    µηάνηµα.
      
    Regolazioni e manutenzione su questa macchina devono essere fatti solo
    da personale specializzato.
    Assicurarsi che la macchina sia SPENTA prima di incominciare qualsiasi
    lavoro di manutenzione (guasti, riparazioni etc.)
      
    Justering eller vedlikehold på denne maskinen skall bare utføres av
    kvalifiserte personell.
    Forsikre deg om at strømmen er slått av før du påbegynner noe som helst
    vedlikeholdsarbeid (feilsøking, reparasjon osv.) 
    						
    							Page 55
      
    Aanpassingen of onderhoud aan deze machine dient alleen uitgevoerd te
    worden door bekwaam personeel.
    Zorg ervoor dat de machine UITgeschakeld is voordat er enig
    onderhoudswerk wordt verricht (troubleshooting, reparaties etc.)
      
    Afinações ou manutenção nesta maquina, deverão ser efectuadas sómente
    por pessoal qualificado.
    Certifique-se que a maquina se encontra desligada sempre que iniciar
    qualquer tipo de trabalho de manutenção. (identifação de avarias,
    reparação etc.)
    	 		 	
    	Justeringar och underhåll på denna maskin skall endast utföras av
    kvalificerad personal.
    Försäkra dig om att strömmen är avstängd innan underhållsarbete påbörjas
    (felsökning, reparationer etc.)
    
     
    
     
    
    
    Tätä laitetta saa säätää tai huoltaa vain siihen ammattipätevyyden omaava
    henkilökunta.
    Varmista, että laite on kytketty POIS PÄÄLTÄ ennen työn aloittamista. 
    						
    							Page 56 7-1 Greasing the Gun Assy
    The Gun Assembly should be checked for correct operation daily.
    The gun Assembly should be re-greased every 6 months.
    1. Remove 6off security screw (M6x16), 1off security screw (M6x16), with flat
    washer, and remove the Front Vac-Form.
    2. Apply grease to the areas shown below.
    Use silicon grease Part No. 95000018
    3. Reassemble in reverse order.
    Security screw (M6x16)
    Security screw (M6x16) Security screw (M6x16)
    Flat washer
    Front Vac-Form 
    						
    							Page 57 7-2 Removing the Gun Assy
    1. Remove 4off security screw (M6x20), with flat washer.
    2. Remove the Top Vac-Form by lifting it up and over the Gun Assy.
    Flat washer
    Security screw (M6x20)
    Top Vac-Form
    Security screw (M6x20)Security screw (M6x20)
    Top Vac-Form 
    						
    							Page 58 3. Remove 6off security screw (m6x16) and remove the Front Vac-Form.
    4. Remove 40ff pozi head screw (M6x35) and remove the Gun Assy Cover.
    Security screw (M6x16)
    Security screw (M6x16)
    Front Vac-Form
    Pozi head screw (M6x35)Pozi head screw (M6x35)
    Gun Assy Cover 
    						
    							Page 59 5. Remove the 2off upper security screws (M6x20), slacken the 2off lower security
    screws (M6x20) and remove the Rear Access Panel.
    6. Remove 1off hex head screw (M8x35), with flat washer.
    Security screw (M6x20)
    Security screw (M6x20) (loosen) Rear Access Panel
    Flat washer
    Hex head screw (M8x35) 
    						
    							Page 60
    7. Disconnect the connector.
    8. Remove 2off hex head screws (M8x25), with flat washers, and withdraw the Gun
    Assy while lifting up the Gun Assy Cover.
    9. Reassemble in reverse order.
    Note: After refitting the Gun Assy ensure that the Gun is reinitialized. (see 6-2-4-2 page 47)
    Gun Assy Cover
    Hex head screw (M8x25)
    Flat washer
    Gun Assy
    Connector 
    						
    All Namco manuals Comments (0)