Namco Aqua Jet Operators Manual
Here you can view all the pages of manual Namco Aqua Jet Operators Manual. The Namco manuals for Games are available online for free. You can easily download all the documents as PDF.
Page 21
Page PB 6-3-2-1 High Score Initialization a. Select “HIGH SCORE INITIALIZE” on the GAME OPTIONS screen and press the start button. The screen will change to the HIGH SCORE INITIALIZE screen. b. Move the Control Arm up or down to select the required item. c. The high score is initialized (reset) by pressing the start button, and the screen returns to the GAME OPTIONS screen. d. If “NO is selected and the start button pressed, nothing is reset and the screen returns to the GAME OPTIONS screen. HI SCORE...
Page 22
Page 25 6-3-3 I/O Test a. Select item (3) “I/O TEST” on the menu screen. b. Move the Control Arm up or down to select the required item. c. Press the start button to enter the selected test. d. Select “EXIT” and press the start button to return to the menu scr\ een I/O TEST DIP 12345678 .................................... (a) SWITCH TEST .................................... (b) AIR SPRING TEST .................................... ( c ) EXIT CONTROL:CHOOSE START:ENTER (a) Displays the state of the PCB...
Page 23
Page PB 6-3-3-1 Switch Test a. Select “SWITCH TEST” on the menu screen and press the start button. The following screen is displayed. b. Operate the accelerator lever and start button together to return to menu screen I/O TEST TEST SW ON............... (a) COIN SW OFF............... (b) SERVICE SW OFF............... ( c ) START BUTTON OFF............... (d) ACCEL LEVER 0000 0000 FREE............... (e) SWING0000 0000 CENTRE........... ( f ) HANDLE POLE 0000 0000............... ( g ) START+LEVER:EXIT (a)...
Page 24
Page 27 6-3-3-2 Air Spring Test WARNING The ride moves during the Air Spring test. Ensure that hands and feet are clear before starting the test. a. Select ‘AIR SPRING’ test on the I/O TEST screen and press the start button. The following screen is displayed. b. Move the Control Arm up or down to select the required item. c. Press the start button to enter the selected test. d. Select “EXIT” and press the start button to return to the menu screen AIR SPRING TEST NOW AIR SPRING OFF...
Page 25
Page PB MONITOR TEST GRADATION PATTERN CROSSHATCH PATTERN [CRT] CROSSHATCH PATTERN [PROJECTOR] WHITE WINDOW [H] WHITE WINDOW [M] WHITE WINDOW [L] INTERLACE PATTERN VIEW ANGLE ADJUST [CRT] VIEW ANGLE ADJUST [PROJECTOR] FULL WHITE EXIT CONTROL:CHOOSE START:ENTER 6-3-4 Monitor Test a. Select “MONITOR TEST” on the menu screen and press the start button. The following screen is displayed. b. Select an item by moving the control arm up or down. When the start button is pressed the screen will change to the...
Page 26
Page 29 6-3-5 Sound Test a. Select “SOUND TEST ” on the menu screen and press the start button. The following screen is displayed. b. Move the Control Arm up or down to select the required item. c. Press the start button to enter the selected test. d. Move the control arm up or down to alter the setting of the selected item. d. Select “EXIT” and press the start button to return to the menu screen SOUND TEST `[DEFAULT IN GREEN] GAME VOLUME FRONT SP 2C.................... (a) TANK S P 2 C ..................
Page 27
Page PB 6-3-6 ADS Data Select “ADS DATA ” on the menu screen and press the start button. The book keeping data for the game will be displayed. 6-3-7 Others Select “OTHERS” on the menu screen and press the start button. This screen is used to test the PCB and to reset the game to factory settings.
Page 28
Page 31 7 INITIALIZATION Adjustments When Replacing Parts (Initialization) The following adjustments should always be performed after replacing the game PC board, ROM, or Control Pots. The game will not operate correctly if these adjustments are not made. a) Ensure that Control Handle assembly and Ride assembly are in the neutral stand-by position. b) Slide the test switch “ON” while pressing the service switch. The following screen will be displayed on the monitor. VOLUME INITIALIZE TEST SW ON COIN...
Page 29
Page PB 8. REMOVING AND REPLACING ASSEMBLIES AND PARTS. WARNING • Adjustments or maintenance on this machine should be carried out by qualified personnel only. • Do not make any alterations to this machine without prior approval. Doing so could cause unforeseeable danger. • Only parts specified by Namco Europe Ltd. should be used when replacing or repairing parts (including screws). • Ensure that power to the machine is turned OFF before commencing any maintenance work (troubleshooting, repairs etc.) •...
Page 30
Page 33 8-2 Ride Assembly 8-2-1 Replacing the Swing Potentiometer WARNING • Make sure that the power is turned OFF before commencing any work. • Do not let any one get on the ride assembly while replacing the potentiometer to prevent injury by trapped hands or fingers. 1) Remove the two pozi head screws (with flat and spring washers)(M5x10) and remove the potentiometer cover. 2) Remove the two pozi head screws (with flat and spring washers)(M5x10) and remove the maintenance cover. 3) Disconnect the...