Motorola Mc3090z Owners Manual
Have a look at the manual Motorola Mc3090z Owners Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 249 Motorola manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Technical Specifications A - 9 SE4500 Standard Range Imager Decode Zones SE4500-SR Figure A-3 shows the decode zone for the SE4500-SR. Typical values appear. Table A-3 lists the typical distances for selected bar code densities. The minimum element width (or “symbol density”) is the width in mils of the narrowest element (bar or space) in the symbol. Figure A-3SE4500-SR Decode Zone In. cm0 20 mil Code 39 Depth of Field 24.7 5 10 15 20 25 012.7 25.438.1 50.863.5 13 mil (100% UPC) 14.7 1.615.5 15 mil PDF417 0 cmW i d t h o f F i e l d 0 4.511.4 922.9 22.9 * * * Minimum distance determined by symbol length and scan angle. 9 11.4 in. Note: Typical performance at 73˚F (23˚C) on high quality symbols in normal room light. Vcc = 3.3V 4.5 12.4 15 mil Data Matrix 2.8 10.1 10 mil PDF417 * 10.6 7.5 mil Code 39 * 6.67 mil PDF417 3.47.1 5 mil Code 39 2.17.5
A - 10 MC919Z Integrator Guide Supplement Table A-5 SE4500-SR Decode Distances Symbol Density/ Bar Code TypeBar Code Content/ ContrastNote 2 Typical Working Ranges NearFar 5.0 mil Code 39 ABCDEFGH 80% MRD2.1 in 5.33 cm7.5 in 19.05 cm 6.67 mil PDF4174 Col, 20 Rows 80% MRD3.4 in 8.64 cm7.1 in 18.03 cm 7.5 mil Code 39ABCDEF 80% MRDNote 1 10.6 in 26.92 cm 10 mil PDF4173 Col, 17 Rows 80% MRDNote 1 10.1 in 25.65 cm 13 mil UPC-A012345678905 80% MRD1.6 in 5.08 cm15.5 in 39.37 cm 15 mil PDF41780% MRD Note 1 14.7 in 37.34 cm 15 mil Data Matrix18 x 18 Modules 80% MRD2.8 in 7.11 cm12.4 in 31.50 cm 20 mil Code 39123 80% MRDNote 1 24.7 in 62.74 cm Notes: 1. Near distances are field-of-view (FOV) limited. 2. Contrast is measured as Mean Reflective Difference (MRD) at 670 nm. 3. Working range specifications at temperature = 23°C, pitch=18°, roll=0°, skew=0°, photographic quality, ambient light ~30 ft-c, humidity 45-70% RH. 4. Distances measured from front edge of scan enginechassis.
Technical Specifications A - 11 SE4500-HD Figure A-4 shows the decode zone for the SE4500-HD. Typical values appear. Table A-6 lists the typical distances for selected bar code densities. The minimum element width (or “symbol density”) is the width in mils of the narrowest element (bar or space) in the symbol. Figure A-4SE4500-HD Decode Zone Depth of Field 13 mil (100% UPC) 6.4 5 mil PDF417 1.66.8 1.63.8 15 mil PDF417 0 cm W i d t h o f F i e l d 0 5.1 4.0 10.2 10.2 * * Minimum distance determined by symbol length and scan angle. 4.0 in.Note: Typical performance at 73°F (23°C) on high quality symbols in normal room light. Vcc = 3.3V 7.5 mil Code 39*6.1 6.67 mil PDF4171.34.5 10 mil PDF417*5.1 4 mil PDF4171.83.5 2.05.1 2.03 mil Code 391.63.8 5 mil Code 39*5.0 5 mil Data Matrix1.83.6 In . cm0 012 30.5 2 5.14 10.26 15.28 20.310 25.4 11.1 20 mil Code 39 * 2.06.115 mil Data Matrix
A - 12 MC919Z Integrator Guide Supplement Table A-6SE4500-HD Decode Distances Symbol Density/ Bar Code TypeBar Code Content/ ContrastNote 2 Typical Working Ranges NearFar 3.0 mil Code 3980% MRD 1.6 in 4.06 cm3.8 in 9.65 cm 4.0 mil PDF41780% MRD 1.8 in 4.57 cm3.5 in 8.89 cm 5.0 mil Code 39ABCDEFGH 80% MRDNote 1 5.0 in 12.70 cm 5.0 mil PDF41780% MRD 1.6 in 4.06 cm3.8 in 9.65 cm 5 mil Data Matrix18 x 18 Modules 80% MRD1.8 in 4.57 cm3.6 in 9.15 cm 6.67 mil PDF4174 Col, 20 Rows 80% MRD1.3 in 3.30 cm4.5 in 11.43 cm 7.5 mil Code 39ABCDEF 80% MRDNote 1 6.1 in 15.49 cm 10 mil PDF4173 Col, 17 Rows 80% MRDNote 1 5.1 in 12.95 cm 13 mil UPC-A012345678905 80% MRD1.6 in 4.06 cm6.8 in 17.27 cm 15 mil PDF41780% MRD Note 1 6.4 in 16.26 cm 15 mil Data Matrix18 x 18 Modules 80% MRD2.0 in 5.08 cm6.1 in 15.49 cm 20.0 mil Code 39123 80% MRDNote 1 11.1 in 28.19 cm Notes: 1. Near distances are FOV limited. 2. Contrast is measured as Mean Reflective Difference (MRD) at 670 nm. 3. Working range specifications at temperature = 23°C, pitch=18°, roll=0°, skew=0°, photographic quality, ambient light ~30 ft-c, humidity 45-70% RH. 4. Distances measured from front edge of scan enginechassis.
Technical Specifications A - 13 Mobile Computer Pin-Outs Figure A-5Pin Locations m Table A-7Pin-Outs PIN NumberSignal NameFunction 1 USB_GND USB 2 USB_D_PLUS USB 3 TXD RS232C 4 RXD RS232C 5 DCD RS232C 6 RTS RS232C 7 DSR RS232C 8 GND Ground, 2.5A max. 9 RI RS232C 10 CRADLE_DET Grounded by cradle when in cradle 11 DTR RS232C 12 Not connected Not connected 13 POWER_IN 12V, 2.5A max 14 CTS RS232C 15 USB_5V_DET USB 16 USB_D_MINUS USB 17 EXT_PWR_OUT 3.3V @500mA 18 17 9
A - 14 MC919Z Integrator Guide Supplement Accessory Specifications Single Slot Serial/USB Cradle Four Slot Ethernet Cradle Table A-8Single SLot Serial/USB Cradle Technical Specifications FeatureDescription Dimensions Height: 13.02 cm (5.13 in.) Width: 15.24 cm (6.0 in.) Depth: 15.24 cm (6.0 in.) Input Power 12 VDC Interface Serial and USB Operating Temperature -25°C to 50°C (-13°F to 122°F) Storage Temperature -40°C to 70°C (-40°F to 158°F) Charging Temperature 0°C to 40°C (32°F to 104°F) Humidity 5% to 95% non-condensing Drop 76.2 cm (30.0 in.) drops to vinyl tiled concrete at room temperature Electrostatic Discharge (ESD) +/- 15 kV air +/- 8 kV contact Table A-9Four Slot Ethernet Cradle Technical Specifications FeatureDescription Dimensions Height: 10.16 cm (4.0 in.) Width: 48.77 cm (19.00 in.) Depth:15.24 cm (6.0 in.) Input Power 12 VDC Interface Ethernet Operating Temperature -25°C to 50°C (-13°F to 122°F) Storage Temperature -40°C to 70°C (-40°F to 158°F) Charging Temperature 0°C to 40°C (32°F to 104°F)
Technical Specifications A - 15 Four Slot Charge Only Cradle Four Slot Battery Charger Humidity 5% to 95% non-condensing Drop 76.2 cm (30.0 in.) drops to vinyl tiled concrete at room temperature Electrostatic Discharge (ESD) +/- 15 kV air +/- 8 kV contact Table A-9Four Slot Ethernet Cradle Technical Specifications (Continued) FeatureDescription Table A-10Four Slot Charge Only Cradle Technical Specifications FeatureDescription Dimensions Height: 10.16 cm (4.0 in.) Width: 48.77 cm (19.00 in.) Depth:15.24 cm (6.0 in.) Input Power 12 VDC Operating Temperature -25°C to 50°C (-13°F to 122°F) Storage Temperature -40°C to 70°C (-40°F to 158°F) Charging Temperature 0°C to 40°C (32°F to 104°F) Humidity 5% to 95% non-condensing Drop 76.2 cm (30.0 in.) drops to vinyl tiled concrete at room temperature Electrostatic Discharge (ESD) +/- 15 kV air +/- 8 kV contact Table A-11Four Slot Battery Charger Technical Specifications FeatureDescription Dimensions Height: 10.16 cm (4.0 in.) Width: 15.24 cm (6.0 in.) Depth: 15.24 cm (6.0 in.) Input Power 12 VDC Operating Temperature 0°C to 45°C (32°F to 113°F) Storage Temperature -40°C to 70°C (-40°F to 158°F) Charging Temperature 0°C to 40°C (32°F to 104°F)
A - 16 MC919Z Integrator Guide Supplement Magnetic Stripe Reader Figure A-6Magnetic Stripe Reader (MSR) Technical Specifications (Continued) Humidity 5% to 95% non-condensing Drop 76.2 cm (30.0 in.) drops to vinyl tiled concrete at room temperature Electrostatic Discharge (ESD) +/- 15 kV air +/- 8 kV contact Table A-11Four Slot Battery Charger Technical Specifications (Continued) FeatureDescription FeatureDescription Interface Serial with baud rate up to 19,200 Format ANSI, ISO, AAMVA, CA DMV, user-configurable generic format Swipe Speed 5 to 50 in. (127 to 1270 mm) /sec, bi-directional Decoders Generic, Raw Data Mode Buffered, unbuffered Track Reading Capabilities Tracks 1 and 3: 210 bpi Track 2: 75 and 210 bpi, autodetect Operating Temperature -25°C to 50°C (-13°F to 122°F) Storage Temperature -40°C to 70°C (-40°F to 158°F) Humidity 5% to 95% non-condensing Drop 1.22 m (4 ft.) drops to concrete Electrostatic Discharge (ESD) +/- 15 kV air +/- 8 kV contact
Technical Specifications A - 17 Accessory CAM and MSR Pin-Outs Figure A-7CAM and MSR Serial Connector Table A-12CAM and MSR Serial Connector Pin-outs PinSignal 1 USB_5V_DET 2 USB_D_MINUS 3 USB_D_PLUS 4 GND 5 GND 6 PWR_EXT_OUT 7 CRADLE_DET* 8 DSR 9 DCD 10 TXD 11 CTS 12 DTR 13 RI 14 RTS 15 RXD