Motorola Mc3090z Owners Manual
Have a look at the manual Motorola Mc3090z Owners Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 249 Motorola manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Tag Locator 5 - 3 Locating Tags Using a .csv File 1.Select the Import Tags button to import a list of saved tags from a .csv file. The following window appears. Figure 5-2Opening a .csv File 2.Select the desired .csv file to import the tags to the list. Figure 5-3Tag List 3.Select a tag from the list to search.
5 - 4 MC919Z Integrator Guide Supplement 4.Select the Locate button or press and hold the trigger. Move the mobile computer in all directions to get the relative position of the tag, indicated by a beep, the vertical progress bar, or both. Figure 5-4Tag Search Use the Options menu to turn the beeper on and off and to display data in ASCII or hexadecimal format. Figure 5-5Options Menu
Chapter 6 Troubleshooting Introduction This chapter provides troubleshooting solutions for potential problems during MC919Z operating. Troubleshooting MC919Z Table 6-1Troubleshooting the MC919Z ProblemCauseSolution MC919Z does not turn on.Battery not charged. Charge or replace the battery. Battery not installed properly.Ensure battery is installed properly. System crash. Perform a warm boot. If the MC919Z still does not turn on, perform a cold boot. Rechargeable battery did not charge.Battery failed. Replace battery. If the MC919Z still does not operate, try a warm boot, then a cold boot. Refer to Resetting the MC9190 in the MC9190-G Integration Guide. MC919Z removed from cradle while battery was charging.Insert MC919Z in cradle and begin charging. The battery requires approximately four hours to recharge fully. Cannot see characters on display.MC919Z not powered on.Press the Power button.
6 - 2 MC919Z Integrator Guide Supplement During data communication, no data was transmitted, or transmitted data was incomplete.MC919Z removed from cradle or unplugged from host computer during communication.Replace the MC919Z in the cradle, or reattach the Synchronization cable and re-transmit. Incorrect cable configuration.See the System Administrator. Communication software was incorrectly installed or configured.Perform setup. Refer to refer to the MC9190-G Integration Guide for details. Ensure that Microsoft ActiveSync 4.5 or greater is installed on the host computer. No sound is audible. Volume setting is low or turned off.Turn on or increase volume. MC919Z turns itself off. MC919Z is inactive. The MC919Z turns off after a period of inactivity. If the MC919Z is running on battery power, this period can be set to 30 sec., 1, 2, 3, 4, 5 or 6 minutes. If the MC919Z is running on external power, this period can be set to 1, 2, 3, 5, 10, 15 and 30 minutes. For Windows Mobile 6.5 devices, Check the power settings by tapping Start > Settings > System > Power > Advanced. Change the setting if you need a longer delay before the automatic shutoff feature activates. Battery is depleted. Replace the battery. Battery is not inserted properly.Insert the battery properly. Tapping the window buttons or icons does not activate the corresponding feature.LCD screen not aligned correctly.Re-calibrate the screen. The system is hung. Warm boot the system. To perform a warm boot (refer to Resetting the MC9190-G in the MC9190-G Integration Guide). A message appears stating that the MC919Z memory is full.Too many files stored on the MC919Z.Delete unused memos and records. You can save these records on the host computer. Too many applications installed on the MC919Z.If you have installed additional applications on the MC919Z, remove them to recover memory. For Windows Mobile 6.5 devices, tap Start > Settings > System > Remove Programs. Select the unused program and tap Remove. Table 6-1Troubleshooting the MC919Z (Continued) ProblemCauseSolution
Troubleshooting 6 - 3 Bluetooth Connection The MC919Z does not accept scan input.Scanning application is not loaded.Verify that the MC919Z is loaded with a scanning application. See the System Administrator. Unreadable bar code. Ensure the symbol is not defaced. Distance between exit window and bar code is incorrect.Ensure MC919Z is within proper scanning range. MC919Z is not programmed for the bar code.Ensure the MC919Z is programmed to accept the type of bar code being scanned. MC919Z is not programmed to generate a beep.If a beep on a good decode is expected and a beep is not heard, check that the application is set to generate a beep on good decode. Battery is low. If the scanner stops emitting a laser beam when the trigger is pressed, check the battery level. When the battery is low, the scanner shuts off before the MC919Z low battery condition notification. Note: If the scanner is still not reading symbols, contact the distributor or Zebra. Table 6-1Troubleshooting the MC919Z (Continued) ProblemCauseSolution Table 6-2Troubleshooting Bluetooth Connection ProblemCauseSolution MC919Z cannot find any Bluetooth devices nearby.Too far from other Bluetooth devices.Move closer to the other Bluetooth device(s), within a range of 10 meters (30 feet). The Bluetooth device(s) nearby are not turned on.Turn on the Bluetooth device(s) you wish to find. The Bluetooth device(s) are not in discoverable mode.Set the Bluetooth device(s) to discoverable mode. If needed, refer to the device’s user documentation for help. MC919Z keeps powering down to protect memory contents.The MC919Z’s battery is low. Recharge the battery. There is a delay in the Bluetooth stack re-initializing during a resume from suspend.This is the normal behavior. No solution required.
6 - 4 MC919Z Integrator Guide Supplement Four Slot Charge Only Cradle Four Slot Ethernet Cradle Table 6-3Troubleshooting the Four Slot Charge Only Cradle ProblemCauseSolution MC919Z charge indicator LED does not light. Cradle is not receiving power.Ensure the power supply is securely connected and receiving power. MC919Z is not seated correctly in the cradle. Ensure the battery is properly installed in the MC919Z, and re-seat the MC919Z in the cradle. The battery is not properly installed in the MC919Z. The battery in the MC919Z is faulty.Verify that other batteries charge properly. If so, replace the faulty battery. Note: The Four Slot Charge Only Cradle has no power indication. Table 6-4Troubleshooting the Four Slot Ethernet Cradle SymptomCauseSolution Attempt by the MC919Z to ActiveSync failed.Cannot perform ActiveSync connection.ActiveSync over an Ethernet connection is not available with Windows Mobile 6.5 and ActiveSync 4.5. During communications, no data was transmitted, or transmitted data was incomplete.MC919Z removed from cradle during communications.Replace MC919Z in cradle and retransmit. MC919Z has no active connection.An icon will be visible in the status bar if a connection is currently active. MC919Z has successfully connected through the cradle, but no data is being transmitted over the connection.Data is being transferred over the wireless link.Temporarily disable the WLAN connection to force data transmission through the cradle. Once you have completed your data transmission, re-enable the WLAN connection.
Troubleshooting 6 - 5 All Communication Status LEDs are flashing red.The cradle could not configure itself, or it has lost the lease on its IP address.Connect the cradle to an Ethernet network with a correctly functioning DHCP server. Failed automatic cradle configuration via local DHCP service.Connect a properly configured DHCP server or DHCP relay agent to the subnet, and power cycle the cradle. Check the DHCP server log to verify that the cradle is receiving a response to its DHCP request. The Ethernet link may be down.Ensure the ethernet cable is connected to an active hub. Communication Status LED does not light up.MC919Z has been inserted incorrectly into the cradle.Remove, wait a minute, and then reinsert the MC919Z, ensuring it fits snugly onto the connector at the bottom of the cradle. Cradle is not receiving power.Ensure the power supply is securely connected and receiving power. Battery is not recharging.MC919Z removed from the cradle too soon.Replace the MC919Z into the cradle. It can take up to four hours to recharge a completely depleted battery pack if MC919Z is suspended or longer if the MC919Z is on. For Windows Mobile 6.5 devices, view battery status by tapping Start > Settings > System > Power. Battery is faulty. Verify that other batteries charge properly. If so, replace the faulty battery. MC919Z is not inserted correctly into the cradle.Remove the MC919Z and reinsert it correctly. Verify charging is active. For Windows Mobile 6.5 devices, view battery status by tapping Start > Settings > System > Power. Warning Message - “!” Unable to obtain a server assigned IP address. Try again later or enter an IP address in Network Settings.”This message occurs if a suspend/resume cycle is performed and the MC919Z is not associated (e.g. due to being out of range).Ta p OK to close the message. The MC919Z will obtain address information and communicate through the ethernet cradle. Table 6-4Troubleshooting the Four Slot Ethernet Cradle (Continued) SymptomCauseSolution
6 - 6 MC919Z Integrator Guide Supplement Four Slot Spare Battery Charger Single Slot Serial/USB Cradle Table 6-5Troubleshooting The Four Slot Spare Battery Charger SymptomPossible CauseAction Batteries not charging.Battery was removed from the charger or charger was unplugged from AC power too soon.Ensure the charger is receiving power. Confirm main battery is charging. If a battery is fully depleted, it can take up to four hours to fully recharge a battery. Battery is faulty. Verify that other batteries charge properly. If so, replace the faulty battery. Battery contacts not connected to charger.Verify that the battery is seated in the battery well correctly with the contacts facing down. Table 6-6Troubleshooting the Single Slot Serial/USB Cradle SymptomPossible CauseAction LEDs do not light when MC919Z or spare battery is inserted.Cradle is not receiving power.Ensure the power cable is connected securely to both the cradle and to AC power. MC919Z is not seated firmly in the cradle.Remove and re-insert the MC919Z into the cradle, ensuring it is firmly seated. Spare battery is not seated firmly in the cradle.Remove and re-insert the spare battery into the charging slot, ensuring it is firmly seated. MC919Z battery is not charging.MC919Z was removed from cradle or cradle was unplugged from AC power too soon.Ensure cradle is receiving power. Ensure MC919Z is seated correctly. Confirm that the battery is charging. If a MC919Z battery is fully depleted, it can take up to four hours to fully recharge a battery (if the MC919Z is off and longer if the MC919Z is operating). For Windows Mobile 6.5 devices, view battery status by tapping Start > Settings > System tab > Power. Battery is faulty. Verify that other batteries charge properly. If so, replace the faulty battery. The MC919Z is not fully seated in the cradle.Remove and re-insert the MC919Z into the cradle, ensuring it is firmly seated. Spare battery is not charging.Battery not fully seated in charging slot.Remove and re-insert the spare battery into the cradle, ensuring it is firmly seated. Battery inserted incorrectly.Ensure the contacts are facing down and toward the back of the cradle. Battery is faulty. Verify that other batteries charge properly. If so, replace the faulty battery.
Troubleshooting 6 - 7 Cable Adapter Module During data communications, no data was transmitted, or transmitted data was incomplete.MC919Z removed from cradle during communications.Replace MC919Z in cradle and retransmit. Incorrect cable configuration.See the System Administrator. Communications software is not installed or configured properly.Perform setup as described in the Accessories section of the MC9190-G Integration Guide. Ensure that Microsoft ActiveSync 4.5 or greater is installed on the host computer. Table 6-6Troubleshooting the Single Slot Serial/USB Cradle (Continued) SymptomPossible CauseAction Table 6-7Troubleshooting The Cable Adapter Module SymptomPossible CauseAction MC919Z battery is not charging.MC919Z was removed from CAM or CAM was unplugged from AC power too soon.Ensure CAM is receiving power. Ensure MC919Z is attached correctly. Confirm that the battery is charging. If a MC919Z battery is fully depleted, it can take up to four hours to fully recharge a battery (if the MC919Z is off and longer if the MC919Z is operating). For Windows Mobile 6.5 devices, view battery status by tapping Start > Settings > System > Power. Battery is faulty. Verify that other batteries charge properly. If so, replace the faulty battery. The MC919Z is not fully attached to the CAM.Detach and re-attach the CAM to the MC919Z, ensuring it is firmly connected. During data communications, no data was transmitted, or transmitted data was incomplete.MC919Z detached from CAM during communications.Re-attach MC919Z to CAM and retransmit. Incorrect cable configuration.See the System Administrator. Communications software is not installed or configured properly.Perform setup as described in the Accessories section of the MC9190-G Integration Guide.
6 - 8 MC919Z Integrator Guide Supplement Magnetic Stripe Reader Table 6-8Troubleshooting the Magnetic Stripe Reader SymptomPossible CauseAction MSR cannot read card.MC919Z detached from MSR during card swipe.Re-attach MC919Z to MSR and reswipe the card. Faulty magnetic stripe on card.See the System Administrator. MSR application is not installed or configured properly.Ensure the MSR application is installed on the MC919Z. Ensure the MSR application is configured correctly. MC919Z battery is not charging.MC919Z was removed from MSR or MSR was unplugged from AC power too soon.Ensure MSR is receiving power. Ensure MC919Z is attached correctly. Confirm that the battery is charging. If a MC919Z battery is fully depleted, it can take up to four hours to fully recharge a battery (if the MC919Z is off and longer if the MC919Z is operating). For Windows Mobile 6.5 devices, view battery status by tapping Start > Settings > System > Power. Battery is faulty. Verify that other batteries charge properly. If so, replace the faulty battery. The MC919Z is not fully attached to the MSR.Detach and re-attach the MSR to the MC919Z, ensuring it is firmly connected. During data communications, no data was transmitted, or transmitted data was incomplete.MC919Z detached from MSR during communications.Reattach MC919Z to MSR and retransmit. Incorrect cable configuration.See the System Administrator. Communications software is not installed or configured properly.Perform setup as described in the Accessories section of the MC9190-G Integration Guide.