MikroTik Router OS V3.0 User Manual
Here you can view all the pages of manual MikroTik Router OS V3.0 User Manual. The MikroTik manuals for Router are available online for free. You can easily download all the documents as PDF.
Page 481
watch-address. The default setting means that if watch-address is set and is not reachable, the router will reboot about every 6 minutes. send-email-from(text; default:) - e-mail address to send the support output file from. If not set, the value set in /tool e-mail is used send-email-to(text; default:) - e-mail address to send the support output file to send-smtp-server(text; default:) - SMTP server address to send the support output file through. If not set, the value set in /tool e-mail is used...
Page 482
UPS Monitor Document revision 2.3 (February 6, 2008, 4:08 GMT) This document applies to MikroTik RouterOS V3.0 Table of Contents TableofContents Summary Specifications Description UPSMonitorSetup PropertyDescription Notes Example RuntimeCalibration Description Notes Example UPSMonitoring PropertyDescription Example General Information Summary 0$! +$3 0$! ` a ( !-:- 0!) ...
Page 483
Packages required:ups License required:level1 Home menu level:/system ups Standards and Technologies:APCssmartprotocol Hardware usage:Not significant Description Cabling +$3 0$! &) 0$! $ ! 0$! 8 & 0!) * 0$! +$3 H 7H 0 Router Side (DB9f)SignalDirectionUPS Side (DB9m) 2ReceiveIN2 3SendOUT1 5Ground4 7CTSIN6 9 ...
Page 484
nominal-battery-voltage(read-only: integer) - the UPSs nominal battery voltage rating (this is not the UPSs actual battery voltage) offline-after(read-only: time) - when will the router go offline offline-time(time; default:5m) - how long to work on batteries. The router waits that amount of time and then goes into hibernate mode until the UPS reports that the utility power is back •0- the router will go into hibernate mode according the min-runtime setting and 10% of battery power event. In this case,...
Page 485
Example [admin@MikroTik] system ups> rtc 0 UPS Monitoring Command name:/system ups monitor Property Description battery-charge(percentage) - the UPSs remaining battery capacity as a percent of the fully charged condition battery-voltage- the UPSs present battery voltage. The typical accuracy of this measurement is ±5% of the maximum value (depending on the UPSs nominal battery voltage) frequency(percentage) - when operating on-line, the UPSs internal operating frequency is synchronized to the line within...
Page 486
output-voltage: 226Vload: 45%temperature: 39Cfrequency: 50Hzreplace-battery: nosmart-boost: nosmart-trim: nooverload: nolow-battery: no [admin@MikroTik] system ups> 6 [admin@MikroTik] system ups> monitor 0on-line: noon-battery: yestransfer-cause: Line voltage notch or spikeRTC-running: noruntime-left: 19moffline-after: 4m46sbattery-charge: 94%battery-voltage: 24Vline-voltage: 0Voutput-voltage: 228Vload: 42%temperature: 39Cfrequency: 50Hzreplace-battery: nosmart-boost: nosmart-trim:...
Page 487
VRRP Document revision 1.6 (February 6, 2008, 4:08 GMT) This document applies to MikroTik RouterOS V3.0 Table of Contents TableofContents GeneralInformation Summary Specifications Description Notes VRRPRouters Description PropertyDescription Notes AsimpleexampleofVRRPfailover Description ConfiguringMasterVRRProuter ConfiguringBackupVRRProuter Testingfailover General Information Summary O $ &O$ ! #3-::C O$ ...
Page 489
name(name) - assigned name of the VRRP instance on-backup(name; default:) - script to execute when the node switch to backup state on-master(name; default:) - script to execute when the node switch to master state password(text; default:) - password required for authentication depending on method used can be ignored (if no authentication used), 8-character long text string (for plain-text authentication) or 16-character long text string (128-bit key required for AH authentication) preemption-mode(yes |...