    							INSTALLATION INSTRUCTIONS 
    						
    							Disposal of the packing
    material
    The protective packing materials are
    environmentally safe and can be
    recycled.
    Ensure that any plastic wrappings,
    bags, etc. are disposed of safely and
    kept out of the reach of children.
    Danger of suffocation!
    Disposal of the appliance
    Appliances contain materials which can
    be recycled. Please contact your local
    authorities about recycling in your area.
    Ensure that the machine presents no
    danger to children while being stored
    for disposal. See Important Safety
    Instructions.
    Caring for the environment
    52 
    						
    							Please refer to the installation
    diagram supplied with the machine.
    ,Furniture and fittings installed
    near the machine must be of a
    commercial standard (able to
    withstand the effects of steam).
    Installation options
    –Free-standing
    –Undercounter
    The machine can be installed under a
    continuous counter or sink drain. The
    recess must be at least 60 cm wide,
    60 cm deep and 82 cm high.
    Positioning and securing the
    machine
    To ensure stability, the machine must be
    aligned and screwed to the counter.
    ^Open the door.
    ^Secure the machine to the front edge
    of the worktop using the screws to
    the left and right of the front trim.
    ^When not mounted undercounter,
    floor mounting brackets must be
    used.
    Do not use silicone sealant to seal
    the gaps between the machine and
    any neighboring units. This will
    hinder ventilation to the circulation
    pump.
    Steam Deflector (protects the
    countertop)
    Depending on the requirements for an
    undercounter installation, a steam
    deflector can be ordered from the Miele
    Technical Service Department.
    The underside of the countertop is
    protected from steam damage by a
    stainless steel plate.
    Installation
    53 
    						
    							Removing the lid (if necessary)
    If necessary, remove the lid from the
    machine to make installation possible.
    ^Open the door.
    ^Remove the fixing screws on the left
    and right sides using a phillipshead
    screwdriver.
    ^Pull the machine lid approx. 5 mm
    forwards, lift it upwards and remove.Important for machines with steam
    condenser (depending on model)
    ^To prevent countertop damage by
    steam, the supplied self adhesive
    protective foil (25 x 58 cm) must be
    placed underneath the countertop
    near the steam condenser.
    Installation
    54 
    						
    							Water inlet
    ^The machine must be connected to
    the water supply in accordance with
    local and national regulations.
    ^The washer is constructed so it may
    be connected to a supply without an
    extra non-return valve, unless
    required by code.
    ^An acceptable water pressure (flow
    rate) is 10 - 147 psi. However, the
    recommended pressure is
    25 - 60 psi.
    If the water pressure is below 30 psi,
    the fill time will take longer.
    If the Fill/Drain fault code F..E is
    displayed, contact the Technical
    Service Department.
    ^The machine is supplied to be
    connected to a standard cold (coded
    blue)orhot (coded red) water supply
    to a maximum temperature of 158 °F
    (70 °C.)
    Connect the water intake hoses to the
    cold and hot water faucets.
    If no hot water supply is available, the
    hot water intake hose with thered
    marking needs to be connected to
    cold water by a y-adapter.
    For a DI water connection (H
    2O
    pure), see the next page.^Water valves with
    3/4 male hose
    thread are to be provided on site.
    They should be easily accessible so
    the water supply can be turned off if
    necessary.
    ^The inlet hoses are 5
    ½feet (1.7 m)
    long, terminating in a3/4 female hose
    thread.The water inlet filters in the
    threads must not be removed.
    ^Large surface area filters are
    enclosed in the kit supplied with the
    machine.
    Install these filters between the water
    valve and the water inlet hose (see
    illustration in Machine Care/Cleaning
    the filters in the water inlet). The
    large surface area filter for DI water is
    made from stainless steel and can be
    recognized by its matte surface.
    ,Do not cut the inlet hose or
    damaged it in any way.
    ^
    See the supplied installation diagram.
    Plumbing
    55 
    						
    							DI-Water connection
    The machine comes with a standard
    connection for a pressure-resistant
    system. The recommended water
    pressure (flow rate) is 25 - 60 psi
    however, water pressure of 10 - 147 psi
    is acceptable.
    ^The DI pressure-tested hose (marked
    H
    2O pure) with a3/4 hose thread
    must be connected to the on-site
    water valve for DI purified water.
    If the DI water connection is not
    used, the electronics needs to be
    reprogrammed by a Miele technician.
    The water intake hose remains at the
    rear side of the machine.
    Plumbing
    56 
    						
    							Drainage
    ^The drainage system is fitted with a
    non-return valve which prevents dirty
    water from flowing back into the
    machine via the drain hose.
    ^The machine should preferably be
    connected to aseparatedrainage
    system onsite.
    If separate drainage is not available
    contact your Miele application
    specialist for advice.
    The onsite drain connection point
    should be located between 1 ft.
    (0.3 m) and 3 ft. (1 m)above the
    lower edge of the machine.
    If it is lower than 1 ft. (0.3 m), lay the
    hose in a curve at a height of at least
    1 ft. (0.3 m).
    The drainage system must be able to
    take a minimum drainage flow of
    16 l/min.
    ^The drain hose is approx. 5 ft. (1.5 m)
    long, is flexible and has an internal
    diameter of
    7/8in. (22 mm). It must
    not be shortened. Hose clamps are
    supplied for securing it in position.
    ^
    A longer drain hose (up to 12 ft. [4 m]
    long) is available to order from the
    Miele Technical Service Department.
    ^
    The drainage system must not
    exceed 12 ft. (4 meters).
    ^
    See the supplied installation diagram.
    Plumbing
    57 
    						
    							,All electrical work must be
    performed by a qualified person in
    accordance with local and national
    safety regulations.
    The machine comes equipped for
    connection to a 208 V, 60 Hz, 3 phase
    power supply. It is equipped with a 6 ft.
    long, 12/4 AWG power cord, without a
    plug. A plug, rated for the required
    power which will fit the receptacle, is to
    be supplied by the electrician doing the
    installation. It should be connected to
    the main power supply.
    Voltage: 208 V, 3 phase
    Frequency: 60 Hz
    Rated Load: 6 kW
    Circuit breaker: 3 x 20 A
    Black : connect to L1 (hot)
    Red: connect to L2 (hot)
    White: connect to L3 (hot)
    Green: connect to GND (ground)It can be converted to use a single
    phase power supply in accordance
    with the conversion and wiring diagram.
    The cord must be changed from a
    12/4 AWG to a 10/3 AWG. Contact
    Miele Technical Service for more
    information
    Voltage: 208 V, 1 phase
    Frequency: 60 Hz
    Rated Load: 6 kW
    Circuit breaker: 2 x 30 A
    ^Connection should be made via a
    suitable isolator, with an On/Off
    button easily accessible for servicing
    work.
    ^A damaged power cord must only be
    replaced with a genuine Miele cord
    by a Miele service technician.
    WARNING
    THIS APPLIANCE MUST BE
    GROUNDED
    Electrical connection
    58 
    						
    							Grounding connection
    ^The ground lead must be connected
    to the screw connection point
    (marked with the ground symbol8) at
    the back of the machine.
    The machine must only be operated
    with the voltage, frequency and
    fusing shown on thedata plate
    located on the rear of the machine,
    and on the plinth (behind the service
    panel).
    Theconversion diagramand the
    wiring diagramis secured to the inner
    side of the service panel.
    Removing the service panel
    Disconnect the machine from the
    main electrical supply.
    ^Remove the fixing screws,a, from
    the service panel.
    ^Hold the service panel at both sides
    and pull upwards.
    ^Unscrew the facing,b. Remove the
    plastic protective cap.
    ^See the supplied installation diagram.
    Re-assembling the service
    panel
    ^Refit the plastic protective cap,
    facing and service panel in the
    reverse order to which they were
    removed.
    Electrical connection
    59 
    						
    							English Metric
    Height: 33
    7/16 (325/16) 85 (82) cm
    Width: 23
    5/8 60 cm
    Depth: 23
    5/8 60 cm
    Voltage: 208 V
    Power cord approx. 5’ 11 1.8 m
    Water pressure (flow rate):
    Recommended 25 - 60 psi 1.72 - 4.13 bar
    Acceptable 10 - 147 psi .7 - 10 bar
    Cold or Hot water
    connection up to max. 158°F 70 °C
    DI-Water connection
    Recommended 25 - 60 psi 1.72 - 4.13 bar
    Acceptable 10 - 147 psi .7 - 10 bar
    Delivery head: min. 12 0.3 m
    max. 39
    3/81 m
    Drainage length: max. 13’ 1 4 m
    Water intake hose approx. 5’ 7 1.7 m
    Drain hose: approx. 4’ 7 1.4 m
    Noise level in dB (A):
    Sound pressure level LpA At machine 1 m (39
    3/8) away
    Free stand unit: 64.8 52.9
    Built under counter: 62 50.1
    Technical data
    60 
    						