Miele G 7883 User Manual
Have a look at the manual Miele G 7883 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 171 Miele manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Disposal of the packing material The protective packing materials are environmentally safe and can be recycled. Ensure that any plastic wrappings, bags, etc. are disposed of safely and kept out of the reach of children. Danger of suffocation! Disposal of the appliance Appliances contain materials which can be recycled. Please contact your local authorities about recycling in your area. Ensure that the machine presents no danger to children while being stored for disposal. See Important Safety Instructions. Caring for the environment 52
Please refer to the installation diagram supplied with the machine. ,Furniture and fittings installed near the machine must be of a commercial standard (able to withstand the effects of steam). Installation options –Free-standing –Undercounter The machine can be installed under a continuous counter or sink drain. The recess must be at least 60 cm wide, 60 cm deep and 82 cm high. Positioning and securing the machine To ensure stability, the machine must be aligned and screwed to the counter. ^Open the door. ^Secure the machine to the front edge of the worktop using the screws to the left and right of the front trim. ^When not mounted undercounter, floor mounting brackets must be used. Do not use silicone sealant to seal the gaps between the machine and any neighboring units. This will hinder ventilation to the circulation pump. Steam Deflector (protects the countertop) Depending on the requirements for an undercounter installation, a steam deflector can be ordered from the Miele Technical Service Department. The underside of the countertop is protected from steam damage by a stainless steel plate. Installation 53
Removing the lid (if necessary) If necessary, remove the lid from the machine to make installation possible. ^Open the door. ^Remove the fixing screws on the left and right sides using a phillipshead screwdriver. ^Pull the machine lid approx. 5 mm forwards, lift it upwards and remove.Important for machines with steam condenser (depending on model) ^To prevent countertop damage by steam, the supplied self adhesive protective foil (25 x 58 cm) must be placed underneath the countertop near the steam condenser. Installation 54
Water inlet ^The machine must be connected to the water supply in accordance with local and national regulations. ^The washer is constructed so it may be connected to a supply without an extra non-return valve, unless required by code. ^An acceptable water pressure (flow rate) is 10 - 147 psi. However, the recommended pressure is 25 - 60 psi. If the water pressure is below 30 psi, the fill time will take longer. If the Fill/Drain fault code F..E is displayed, contact the Technical Service Department. ^The machine is supplied to be connected to a standard cold (coded blue)orhot (coded red) water supply to a maximum temperature of 158 °F (70 °C.) Connect the water intake hoses to the cold and hot water faucets. If no hot water supply is available, the hot water intake hose with thered marking needs to be connected to cold water by a y-adapter. For a DI water connection (H 2O pure), see the next page.^Water valves with 3/4 male hose thread are to be provided on site. They should be easily accessible so the water supply can be turned off if necessary. ^The inlet hoses are 5 ½feet (1.7 m) long, terminating in a3/4 female hose thread.The water inlet filters in the threads must not be removed. ^Large surface area filters are enclosed in the kit supplied with the machine. Install these filters between the water valve and the water inlet hose (see illustration in Machine Care/Cleaning the filters in the water inlet). The large surface area filter for DI water is made from stainless steel and can be recognized by its matte surface. ,Do not cut the inlet hose or damaged it in any way. ^ See the supplied installation diagram. Plumbing 55
DI-Water connection The machine comes with a standard connection for a pressure-resistant system. The recommended water pressure (flow rate) is 25 - 60 psi however, water pressure of 10 - 147 psi is acceptable. ^The DI pressure-tested hose (marked H 2O pure) with a3/4 hose thread must be connected to the on-site water valve for DI purified water. If the DI water connection is not used, the electronics needs to be reprogrammed by a Miele technician. The water intake hose remains at the rear side of the machine. Plumbing 56
Drainage ^The drainage system is fitted with a non-return valve which prevents dirty water from flowing back into the machine via the drain hose. ^The machine should preferably be connected to aseparatedrainage system onsite. If separate drainage is not available contact your Miele application specialist for advice. The onsite drain connection point should be located between 1 ft. (0.3 m) and 3 ft. (1 m)above the lower edge of the machine. If it is lower than 1 ft. (0.3 m), lay the hose in a curve at a height of at least 1 ft. (0.3 m). The drainage system must be able to take a minimum drainage flow of 16 l/min. ^The drain hose is approx. 5 ft. (1.5 m) long, is flexible and has an internal diameter of 7/8in. (22 mm). It must not be shortened. Hose clamps are supplied for securing it in position. ^ A longer drain hose (up to 12 ft. [4 m] long) is available to order from the Miele Technical Service Department. ^ The drainage system must not exceed 12 ft. (4 meters). ^ See the supplied installation diagram. Plumbing 57
,All electrical work must be performed by a qualified person in accordance with local and national safety regulations. The machine comes equipped for connection to a 208 V, 60 Hz, 3 phase power supply. It is equipped with a 6 ft. long, 12/4 AWG power cord, without a plug. A plug, rated for the required power which will fit the receptacle, is to be supplied by the electrician doing the installation. It should be connected to the main power supply. Voltage: 208 V, 3 phase Frequency: 60 Hz Rated Load: 6 kW Circuit breaker: 3 x 20 A Black : connect to L1 (hot) Red: connect to L2 (hot) White: connect to L3 (hot) Green: connect to GND (ground)It can be converted to use a single phase power supply in accordance with the conversion and wiring diagram. The cord must be changed from a 12/4 AWG to a 10/3 AWG. Contact Miele Technical Service for more information Voltage: 208 V, 1 phase Frequency: 60 Hz Rated Load: 6 kW Circuit breaker: 2 x 30 A ^Connection should be made via a suitable isolator, with an On/Off button easily accessible for servicing work. ^A damaged power cord must only be replaced with a genuine Miele cord by a Miele service technician. WARNING THIS APPLIANCE MUST BE GROUNDED Electrical connection 58
Grounding connection ^The ground lead must be connected to the screw connection point (marked with the ground symbol8) at the back of the machine. The machine must only be operated with the voltage, frequency and fusing shown on thedata plate located on the rear of the machine, and on the plinth (behind the service panel). Theconversion diagramand the wiring diagramis secured to the inner side of the service panel. Removing the service panel Disconnect the machine from the main electrical supply. ^Remove the fixing screws,a, from the service panel. ^Hold the service panel at both sides and pull upwards. ^Unscrew the facing,b. Remove the plastic protective cap. ^See the supplied installation diagram. Re-assembling the service panel ^Refit the plastic protective cap, facing and service panel in the reverse order to which they were removed. Electrical connection 59
English Metric Height: 33 7/16 (325/16) 85 (82) cm Width: 23 5/8 60 cm Depth: 23 5/8 60 cm Voltage: 208 V Power cord approx. 5’ 11 1.8 m Water pressure (flow rate): Recommended 25 - 60 psi 1.72 - 4.13 bar Acceptable 10 - 147 psi .7 - 10 bar Cold or Hot water connection up to max. 158°F 70 °C DI-Water connection Recommended 25 - 60 psi 1.72 - 4.13 bar Acceptable 10 - 147 psi .7 - 10 bar Delivery head: min. 12 0.3 m max. 39 3/81 m Drainage length: max. 13’ 1 4 m Water intake hose approx. 5’ 7 1.7 m Drain hose: approx. 4’ 7 1.4 m Noise level in dB (A): Sound pressure level LpA At machine 1 m (39 3/8) away Free stand unit: 64.8 52.9 Built under counter: 62 50.1 Technical data 60