Page 71
^Insert the cover strip into the space between the appliance and the side panel. For side-by-side combinations, the cover strips (on both sides of the appliance) are applied to the outermost spaces only. ^ Attach the light switch cover. Attaching the toe-kick panel The maximum height of the toe-kick panel is 4 from the top of the floor. Do not cover the ventilation slits in the base panel. Risk of damage to the appliance. ^If required, cut the toe-kick panel to the required length and height. ^ Attach...
Page 72
Mounting the air separator The air separator on the inside of the freezer door keeps the supply and exhaust air separate. This prevents warm exhaust air from flowing into the machine, optimizing the energy performance of the unit. ^If necessary, shorten the three parts of the air separator. ^Insert the foam pieces back into the sides.^Open the freezer door. ^Wedge the air separator at the bottom of the freezer door, so it connects in place. Installing the appliance 72
Page 73
Aligning the Ice/Water Dispenser If necessary the depth of the Ice/Water dispenser can be aligned from inside the custom door cut-out. This allows the dispenser to be aligned with the custom door to achieve the best possible appearance. ^Press the dispenser back and pull downwards to remove.^Remove the cover and the plastic grill. ^ Remove the screw from the rear casing, then lift the tab on the drip tray up and off. Installing the appliance 73
Page 74
^Pull the rear cover forward and out. ^ To remove the drip tray, begin by carefully unclipping the water sensors, then bend them gently upward. Once the drip tray has been removed, the four aligners can be accessed to adjust the Ice/Water Dispenser to your liking.^Loosen the screws of the four clamps. ^Insert a screwdriver into one of the four slots and push sideways until the dispenser is aligned with the custom door (the gray arrow will adjust to the rear; the black arrow will adjust front)....
Page 75
Attaching the frame and the shelf For3/4 (19 mm) thick custom doors: ^Slide the cover frame onto the Ice/Water Dispenser and press until it is flush with the door surface (be sure the word TOP on the cover frame is upward). For 1 1/2 / (38 mm) thick custom doors: ^ Press the extension frame onto the cover frame. ^ Slide the cover frame onto the dispenser an press until the it is flush with the door surface (be sure the word TOP on the cover frame is upward). ^ Insert the cover frame. Installing the...
Page 76
All plumbing work should be carried out by a suitably qualified and competent person, in accordance with all applicable local and national regulations. The manufacturer is not liable for damage to property due to an incorrect installation or water connection. The water quality must conform to country requirements for drinking water. – The appliance is only suitable for connection to the cold water supply. – The water pressure must be between 25 and 120 psi (1.72-8.25 bar). – A separate shut-off valve...
Page 77
Preparing the water connection The connection to the household water supply must be installed before the appliance is installed. ^Turn off the main water valve to prevent damage caused by leaking water. ^Attach the connecting pipe to the shut-off valve, according to the instructions supplied by the manufacturer of the ice cube maker installation kit. ^Install the connecting pipe. Always observe the indicated clearance dimensions to prevent damage to the connecting pipe when pushing in the...
Page 78
Connecting the water supply When connecting the water pipe to the solenoid valve of the appliance, follow the instructions supplied by the manufacturer of the ice cube maker installation kit. When bending the water pipe, be sure not to kink it, otherwise there is a risk of leaks and water damage. Use bending aids. ^ Remove the cap from the appliance connection,1. ^ Bend the water pipe to suit the location of the connection on the appliance,2.^Push the union nut and seal onto the water pipe. ^Push the end...
Page 79
,Avoid the risk of electrical shock - Plug into a grounded 3-prong outlet. - Do not move the ground plug. - Do not use an adapter. - Do not use an extension cord. Failure to follow these instructions can result in death, fire, or electrical shock. Improper connection of the equipment grounding conductor may result in electric shock. If you are in any doubt as to whether the appliance has been properly grounded, have the appliance checked by a qualified electrician or service technician. Installation,...
Page 80
The Miele RemoteVision system is designed to send messages directly to Miele and/or your PC. For information on set-up and installation of the RemoteVision module see the Installation section of this manual.Be sure your wireless system meets the following requirements –Windows XP ®or newer operating system, Mac®OS X 10.3 or higher –Cable or DSL modem –Microsoft ®Internet Explorer 6 or higher, Safari 2.0 or higher, Firefox 1.5 or higher * Please note that each wireless router manufacturer supplies their...