11kind of powder was used last. This is extremely dangerous. To begin cleaning the dispenser, lower the powder cleaning chute on the rear panel behind the powder reservoir. Be certain that you have a container under the chute to catch all the powder from the reservoir and powder box. Lift the powder shut-off door to allow the powder to flow out. The cleaning brush can be used to remo ve any remaining powder. When empty, remove the reservoir tube and reservoir base by sliding the latch on top of the Dispenser to the left. Then lift the reservoir base up and out. Place the rubber cap on the end of powder tube to prevent powder spillage. Powder feed tube can be easily removed by inserting J shaped rod in small hole in the motor coupling as shown in Figure A. Then unscrew powder-dispensing tube by turning in counter clockwise direction. Be careful to catch any remaining powder that may still be in the tube. Now with the powder chute closed, press in the powder box from the back and release it. The box will pop out slight ly for easy removal and cleaning. To reassemble the dispenser, push the powder box back in unt il it clicks in, slide the powder tube back through the bushings in the powder box and screw it to the motor shaft until finger tight. Place looped end of J shaped rod under motor coupling to assist in aligning the powder feed tube to the coupling threads. See Figure B. Snap the reservoir base back inside the powder box and lock in with the sliding latch. Reinstall the reservoir tube. Figure A Figure B
12 Suggestions/Tips 1. If exposed to a sudden change in temperature, allow the 1200 DPS 30 minutes to stabilize to the new location before use. 2. The hinged dust cover can be tilted back for ease of use. If lowered into place during use, however, it will prevent any air drafts from affecting the accuracy of the scale. The dust cover can also be slid off the hinges and removed if needed. We recommend storing the 1200 DPS with the dust cover on and covering the platform as added protection to prevent anything from hitting the platform and damaging the load cell. 3. The 1200 DPS has a drift warning. If anything causes the readings to drift over 0.3 grains, the scale will beep. The scale should be re-zeroed by pressing the CAL/ZERO button.
131200 DPS Load Sheet Cartridge Load Powder Powder Primer Comments Number Type Weig ht Bullet
14 Lyman Products Corp 475 Smith Street Middletown, CT 06457