    							 11kind of powder was used last. This is extremely 
    dangerous.  To begin cleaning the dispenser, lower the 
    powder cleaning chute on the rear panel behind the powder 
    reservoir.  Be certain that you have a container under the 
    chute to catch all the powder from the reservoir and powder 
    box.  Lift the powder shut-off door to allow the powder to 
    flow out. The cleaning brush can be used to remo ve any 
    remaining powder.  When empty, remove the reservoir tube 
    and reservoir base by sliding the latch on top of the 
    Dispenser to the left.  Then lift the reservoir base up and 
    out.  Place the rubber cap on the end of powder tube to 
    prevent powder spillage. Powder feed tube can be easily 
    removed by inserting J shaped rod in small hole in the 
    motor coupling as shown in Figure A. Then unscrew 
    powder-dispensing tube by turning in counter clockwise 
    direction. Be careful to catch any remaining powder that 
    may still be in the tube.  Now with the powder chute 
    closed, press in the powder box from the back and release 
    it.  The box will pop out slight ly for easy removal and 
    cleaning. To reassemble the dispenser, push the powder 
    box back in unt il it clicks in, slide the powder tube back 
    through the bushings in the powder box and screw it to the 
    motor shaft until finger tight.  Place looped end of J shaped 
    rod under motor coupling to assist in aligning the powder 
    feed tube to the coupling threads. See Figure B.  Snap the 
    reservoir base back inside the powder box and lock in with 
    the sliding latch.  Reinstall the reservoir tube. 
     
     
     
     
     
     
     
     
     
     
               Figure A  Figure B  
    						
    							 12 Suggestions/Tips 
     
    1.  If exposed to a sudden change in temperature, allow the 
    1200 DPS 30 minutes to stabilize to the new location 
    before use. 
    2.  The hinged dust cover can be tilted back for ease of use. If 
    lowered into place during use, however, it will prevent any 
    air drafts from affecting the accuracy of the scale. The dust 
    cover can also be slid off the hinges and removed if needed. 
    We recommend storing the 1200 DPS with the dust cover 
    on and covering the platform as added protection to prevent 
    anything from hitting the platform and damaging the load 
    cell. 
    3.  The 1200 DPS has a drift warning. If anything causes the 
    readings to drift over 0.3 grains, the scale will beep. The 
    scale should be re-zeroed by pressing the CAL/ZERO 
    button.  
    						
    							 131200 DPS Load Sheet 
     
    Cartridge Load  Powder  Powder Primer   Comments 
     Number  Type  Weig ht  Bullet   
    						
    							 14  
    Lyman Products Corp 
    475 Smith Street  
    Middletown, CT 06457  
    						