Home > Lyman > Firearms accessories > Lyman Digital Powder Scale Instructions Manual

Lyman Digital Powder Scale Instructions Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Lyman Digital Powder Scale Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 16 Lyman manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							 
     
    1200 DPS  
    Programmable 
    Digital Powder System 
     
      
    						
    							 2
    WARNINGS AND CAUTIONS: 
     
     
     
    • If the 1200 DPS does not read zero on the display, 
    DO NOT DISPENSE POWDER.  The scale must 
    be zeroed before use. If powder is dispensed with a 
    scale that does not read zero, the charge will not be 
    correct and could be dangerous.  
     
    • Be careful not be get powder between the platform and 
    the scale body. This can affect scale readings. If powde
    r
    does drop into this area, carefully remove it with the
    supplied brush. Do not attempt to remove the platform. 
     
    • Slide switch on underside of unit is to set the (Hz). This 
    is factory preset for domestic models and should not
    need to be changed. Should you have a problem with
    your scale, make sure the switch is set to match the input
    voltage on the power adapter. Domestic 115V is 60 Hz
    and 220V is 50Hz. 
      
    						
    							 3
     
     
    Hinged Dust Cover 
    Powder 
    Feed  
    Tube 
    Platform
    Powder  
    Pan 
    Weight 
    Clea ning 
    Powder Reservoir
    Reservoir 
    Base 
    Powder 
    Box 
    Powder Chute 
    Shown in the down position Powder 
    Shut-Off 
    Storage for Powder Adapter Port for Future Additions 
    Currently Not Used  Powder Adapter Outlet  
    						
    							 4 Congratulations on your purchase of the Lyman 1200 DPS (Digital 
    Powder System). This is a precision piece of equipment and should 
    be handled with care. Before using the 1200 DPS Powder 
    Dispenser, please read these instructions fully and become familiar 
    with the key pads and other operating features listed in the 
    diagrams.  If you have read the instructions and you still do not 
    understand some of the operations, call us at 1-800-22-LYMAN 
    except AK, HI, CT and foreign, who may call 860-632-2020. This 
    operation manual should be kept with the 1200 DPS at all times for 
    easy reference. 
     
    Introduction 
     
    Your New 1200 DPS (digital powder system) is the state of the art 
    in reloading technology.  It is the fastest powder dispenser 
    available and contains a programmable memory to store and recall  
    all of your favorite loads quickly and easily.   
     
    A. Set-Up 
     
    1.  Select a location for the 1200 DPS that is level and stable. 
    It is recommended that the 1200 DPS be located away from 
    a loading bench equipped with a reloading press. Most 
    benches are not heavy enough to prevent vibrations being 
    transferred to the scale. The scale should also be away from 
    any source of air currents. The 1200 DPS is sensitive 
    enough to have readings affected by any of these 
    co nd it io ns. 
    2.  Plug the power adapter into a wall outlet and connect it to 
    the dispenser. Install the powder reservoir tube by pressing 
    it into the top of the unit above the feed tube. 
    3.  Remove end cap from powder feed tube. 
     
    B.  Warm-Up and ON/OFF 
     
    1. Press the ON/OFF button to turn on the 1200 DPS.  
    						
    							 52.  The 1200 DPS is equipped with an automatic 30-minute 
    warm-up feature. This feature allows the precise electronics 
    time to stabilize. The LCD display will alternate between 
    warm-up and a count down clock. In the warm-up mode, 
    the scale, powder dispenser and calibration features will be 
    blocked, however, the user can st ill enter settings into the 
    memory as well as recall and edit exist ing memory. We 
    recommend that the scale be allowed to fully warm-up 
    before use to ensure the highest accuracy level. If this is not 
    possible, the warm-up mode can be cancelled by pressing 
    the CANCEL button. This will allow full access to all o f 
    the 1200 DPS functions, however, accuracy could be 
    slightly reduced until full warm-up is reached. 
    3. To turn off the 1200 DPS, press and hold the ON/OFF 
    button. The 1200 DPS will return to the warm-up mode if 
    the power is shutoff for any length o f t ime. Always turn off 
    the 1200 DPS using the ON/OFF button first, and then 
    unplug the power transformer.  
     
    C.  Calibration 
     
    1.  After warm-up (or if cancel is pressed to exit warm-up) the 
    unit will be in Scale and Dispense mode. We recommend 
    that the scale be calibrated before use. This should be done 
    without the powder pan on the platform.  
    2. Press the CAL/ZERO button to reset the scale to zero. 
    3. Press and hold the CAL/ZERO button. The LCD will 
    display “Cal 20g”. 
    4. Place the 20 gram weight onto the platform and press the 
    CAL/ZERO button again. (Press and Release – Do Not 
    Hold) 
    5.  The LCD will display 0.0 Remove the 20 gram weight. The 
    LCD will display approximately -308.6. 
    6. Press CAL/ZERO one more time to reset zero. 
      
    						
    							 6 D.  Scale and Dispense Mode 
    1.  The scale and dispenser are now active.  Place the powder 
    pan onto the platform and press the CAL/ZERO button to 
    zero the scale. 
    2.  Place the desired smokeless powder (black powder or 
    Pyrodex should NEVER be used) into the powder 
    reservoir. 
    3.  The scale will read in grains (default) unless changed. To 
    select the weighing unit desired, press the UNIT button to 
    select the appropriate grains, grams or ounces.   
    4.  Key in the desired charge weight using the keypad. If you 
    make a mistake press the CANCEL button to clear the 
    complete charge weight or press BACKSPACE to clear 
    the last digit. While the desired charge weight is displayed, 
    press the ENTER button to dispense powder. The 
    dispenser will stop automatically when the selected charge 
    weight is reached. We recommend that the first several 
    charges be placed back into the reservoir. This allows the 
    1200 DPS to fully stabilize and fill the charge tube with 
    powder. After a charge is dispensed, the LCD will display 
    “CT=001” indicating the first charge for 2 seconds. This is 
    a count of the number of charges that have been dispensed. 
    5. Press the ENTER button again to dispense another charge 
    at the selected weight in memory. 
    6.  To pause the dispenser while a charge is being dropped, 
    press the ENTER button.  Press the ENTER button again 
    to resume charging. 
    7.  The dispenser will continue to drop the selected weight 
    until it is changed. To change the selected weight, key in a 
    new weight on the keypad and press the ENTER button. 
    The dispenser will drop the new selected charge weight. 
     
    D-2 Manual - Trickle Mode 
     
    To manually dispense a charge, press and hold the FAST 
    button. The dispenser will run the feed tube at high speed until 
    the button is released. Press and hold the TRICKLE button to  
    						
    							 7run the dispenser at low speed. The feed tube will turn slowly 
    until the button is released. 
     
    D-3 Auto - Trickle Mode 
     
    You can speed up the dispensing process by adding powder to 
    the powder pan and then bring it up to the selected weight by 
    pressing the ENTER button. By utilizing a powder measure to 
    add almost all the powder to the powder pan and using the 
    dispenser to automatically finish trickling to the exact weight, 
    the dispensing time will decrease considerably. 
     
    E. Storing New Memory 
     
    The 1200 DPS will store up to 20 of your favorite loads in 
    memory. Each load in memory has three input lines. 
        Cartridge Name    C=___ 
      Powder Type    P=___ 
        Weight of Powder       W    0.0 
    A load is not stored in memory unt il all t hree input lines 
    have been co mpleted and the enter button pushed after the 
    weight is input.  To edit input mistakes made during entry, 
    the BACK SPACE button will remove the last character 
    entered or pushing the CANCEL button will erase the 
    entire line. 
     
    To store loads in memory: 
     
    1. Press the NEW MEM button. The LCD will display 
    “Mem=01” indicating the first memory position. 
    2. Press the ENTER button. The LCD will flash “CART”,  
    (cartridge) then display “C=_” 
    3.  Enter the name of the cartridge using the cell phone type 
    keypad. Pressing the same key repeatedly will change the 
    letters or number represented by that key. When the proper 
    number or letter is present, wait several seconds and the 
    display will shift to the next space. When the name is  
    						
    							 8displayed, press the ENTER button. The CANCEL , or  
    BACK SPACE can be used for editing the input line.  
    4.  The LCD will flash “POWD”, then display “P=_”. Enter 
    the name of the powder and press the ENTER button. 
    5.  The LCD will flash “WGHT”, then display “W 0.0 gn”. 
    6. Use the UNIT button, if necessary, to change to grams or 
    ounces. 
    7.  Enter the charge weight and press the ENTER button. 
    8.  The load is saved. The LCD will now display “MEM=02” 
    indicating the second memory position, to prompt the user 
    for the next entry. Enter the next load into memory as 
    described above. 
    9. Press the CAL/ZERO but to n to  exit  t he me mo r y mo de. 
     
    F.  Recall A Load From Memory 
     
    1. Press the RECALL button. The LCD will display “C=_ _ 
    _ _”. 
    2. Press the RECALL button again and the LCD will display 
    the first cartridge in the memory.  Press the ENTER button 
    to select this cartridge. The LCD will scroll through the 
    information stored for this cartridge. Press the ENTER 
    button again to dispense this load.  
    WARNING: Be sure that the correct powder is in the 
    reservoir. 
    3.  To scroll through the other loads in memory press the 
    RECALL button repeatedly. The FAST button and the 
    TRICKLE button can also be used to scroll through the 
    memory. Pressing the FAST button will mo ve the displa y 
    to the next memory location and pressing the TRICKLE  
    button will move the display to the previous location. 
    4. Press the CAL/ZERO button to exit from memory and 
    return to the standard Scale and Dispense mode. 
    G. Recall Memory Using A Cartridge Name 
    1.  To recall a load in memory using the cartridge name, press 
    the RECALL button. The LCD will display “C=_ _ _ _”.  
    						
    							 92.  Key in the name of the cartridge using the keypad and press 
    the ENTER button. The LCD will display the cartridge 
    and the scroll through the load information. If more than 
    one cartridge is stored in memory using the same cartridge 
    name, the first one stored will be displayed. 
    3.  To dispense this load, press the ENTER button again. 
    WARNING: Be sure that the correct powder is in the 
    reservoir. 
    4.  Follow steps discussed in F (3) to select other cartridges. 
    5. Press the CAL/ZERO button to exit from memory and 
    return to the standard Scale and Dispense mode. 
     
    H.  Recall Memory Using a Memory Location Number 
      
    The 1200 DPS will store 20 loads in memory. Each load is 
    automatically assigned a number from 1 to 20. It may be faster 
    to locate a load by using its memory location number. 
    1. Press the RECALL button and the LCD will display “C=_ 
    _ _ _”. 
    2. Press the ٠/MEM# button (on the keypad) and the LCD 
    will display “MEM=01” the first memory position. 
    3.  Key in the memory location number and press the ENTER  
    button. The LCD will display the cartridge stored at that 
    memory number and scroll through the load information. 
    4.  If the selected load is not correct, press the ٠/MEM# 
    button again (after step 3) to choose a new memory 
    location number. 
    5. Press  the ENTER button to dispense this load. 
    WARNING: Be sure that the correct powder is in the 
    reservoir. 
     
    I.  Edit Memory 
     
    1.  Follow steps discussed in F,G, or H to select a load in 
    memory that you want to edit. 
    2. Press the EDIT MEM button to edit the cartridge name, 
    powder or weight.   
    						
    							 103. Press the ENTER button to move from cartridge name to 
    powder to weight. 
    4. Press the CANCEL button to clear the entire entry or press 
    the BACKSPACE button to clear the last number or letter. 
    5.  Enter the new information as needed.  Press the ENTER 
    button repeatedly until the next cartridge name appears. 
    6. Press the CAL/ZERO button to exit from memory and 
    return to the standard Scale and Dispense mode. 
     
    J.  Delete Memory 
     
    1.  Follow steps discussed in F, G or H to select a load in 
    memory. 
    2.  Press and hold the CANCEL button to delete the selected 
    lo ad in me mo r y. The  LCD w ill d isp la y t he ne xt  me mo r y 
    entry. 
    3. Press the CAL/ZERO button to exit from memory and 
    return to the standard Scale and Dispense mode. 
    NOTE: The memory location vacated by deleting a load 
    will remain open until a new load is entered into 
    memory at this location. This is to keep the other 
    memory locations the same. They will not shift up one 
    location. 
     
    Cleaning The 1200 DPS 
     
    Caution: Do not turn unit upside down and shake as 
    this could harm the load cell. 
    The cleaning procedure listed below may seem difficult, 
    but after you become familiar with the dispenser it is 
    relatively easy. The 1200 DPS was designed to be 
    sufficient ly disassembled for thorough cleaning 
     
    The 1200 DPS must be cleaned after use or when changing 
    the type of powder.  It is Strongly recommended that 
    powder NOT be left in the powder dispenser when finished 
    loading or when putting it away as you may forget what  
    						
    All Lyman manuals Comments (0)