Step 6 Connect Controller To Wiring Runs Business (4-pair) Wiring Following the numbers on your wiring run labels, plug one end of a jumper cord into the jack panel box (see page 7). Then pull the cord through the controller the same way you pulled the line cords. Now plug the jumper cord into the appropriate jack in a station card in the controller. When all the cords are installed, remove any slack from the cords in the controller by gently pulling down on the cords at the bottom rear of the...
Page 22
Step 7 Install Optional Equipment. The processor card in the main controller has jacks for the call reporting (SMDR) feature, an external alert, and a music on hold source (see figure below). Call Reporting (SMDR) Feature To take advantage of the call reporting (SMDR) feature that the SPIRIT system offers, you will need to install a printer. The black jack (labeled SMDR) on the processor card provides easy identification of where to connect your printer. Caution. Plugging your printer into any jack other...
Page 23
Step 8 Put the Panel Back On. Locate and engage the bottom two hooks on the panel into the housing. Lift up until the top two hooks on the panel engage and then pull down. Tighten the screw at the bottom of the panel. Step 9 Power Up the System. Turn on the power switch located on the bottom left of the power supply unit. A green LED will light. If the LED does not light, make sure that the power supply unit is plugged into a working AC outlet not controlled by a switch. If it still does not light, call...
Page 24
Troubleshooting Your SPIRIT Communications System is designed to work effectively, but a problem may occur. If that happens, the following checklist may be helpful in solving the problem. 3 3 Is the controller properly connected to a source of AC power? The power supply must be plugged in and turned on. The green light near the power switch should be on. Note: A large system may have two power supplies. IS the problem isolated to one SPIRIT telephone? 1.Problems with one station may be related to...
Page 25
CAUTION: lTO REMOVE A CARD, FIRST TURN OFF THE POWER AT THE POWER SUPPLY UNIT(S). lHANDLE THE CARD BY THE PLASTIC FACEPLATE OR LEVERS ONLY. STATIC DISCHARGE CAN DAMAGE THE CARDS. l lONCE REMOVED, CARDS SHOULD NOT BE SET ON A METAL SURFACE. DO NOT TURN ON THE POWER UNTIL YOU ARE SURE ALL CARDS ARE FIRMLY SEATED. nService Technician Diagnostics Diagnostics can be accessed only from station 10. All stations should be idle when the diagnostics are run (no telephone calls in progress). Since the...
Page 26
nWhat Each Test Does This section gives an overview of what each test does. lA ROM test failure indicates a problem with the system CPU card read only memory. lA RAM test failure indicates a problem with the system CPU card read/write memory. lA SYS test failure indicates a problem that can’t be isolated to a specific card. The problem is some type of short or open circuit on or between cards and the backplane. This test requires at least one working station card and one working line card. Bus...
Page 27
Telephone SeIf Test Your telephones may be tested by running a self test procedure at each telephone set. l Press INTERCOM. lLift receiver. l Dial # k #. All of the indicator lights on the set should go ON. lPress any button on the telephone. All of the indicator lights should go OFF. Press any button on the set. l The telephone should ring once. The receiver and the speakerphone microphone should be ON. Now, check the indicator lights at every button by pressing the button. You should be able to...
Page 28
A Line Card Failure By Itself (L1 to L6) A single line card failure with no other failures points to a defective line card. The card should be replaced or exchanged with one known to be good. If the new card also fails, look for a connector or controller problem. If only one station card is in the system, the station card may have a problem. A Station Card Failure By Itself (S1 to S6) A single station card failure with no other failures points to defective station card, an attendant adjunct problem, or a...
Page 29
Key To Indicator Lights During Controller Self Test UnusedUnusedUnused Light 22 Light 23 Light 24 UnusedUnusedUnused Light 19Light 20Light 21 UnusedUnusedUnused Light 16Light 17Light 18 S4S5S6 Light 13 Light 14 Light 15 S1 S2S3 Light 10 Light 11Light 12 L4L5L6 Light 7Light 8Light 9 L1L2L3 Light 4Light 5Light 6 ROMRAM SYS Light 1 Light 2Light 3 Card Numbers LS LSLSCLSLSLS 1 12233P445566 U. Replacement Parts You may order the following SPIRIT Communicator System equipment: PartOrder Number 6-Button...
Page 30
INTERFERENCE INFORMATION FCC REGULATIONS PERTAINING TO THIS EQUIPMENT NOTICE Federal Communications Commission (FCC) rules require that you be notified of the following: FCC (Part 15) This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions in the installation, administration and user manuals may cause interference to radio and television communications. This equipment has been tested and found to comply with the limits for...