Home
>
Lucent Technologies
>
Communications System
>
Lucent Technologies Spirit 2448, 1224 Controller Communications System Customer Installation Instrctions Manual
Lucent Technologies Spirit 2448, 1224 Controller Communications System Customer Installation Instrctions Manual
Here you can view all the pages of manual Lucent Technologies Spirit 2448, 1224 Controller Communications System Customer Installation Instrctions Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 11
nF. Connect Telephone Lines to Controller Remove one line cord for each incoming telephone line from the controller box. Additional cords and longer cords up to 25’ long may be purchased at your phone store or from your AT&T representative. LABEL EACH END OF EACH CORD WITH A LINE CORD LABEL. Pull a line cord through the opening in the bottom rear of the controller and then hook it into the opening in the bottom front. Plug the line cord into a modular jack on the line card of the controller. The line...
Page 12
Step 4 Wiring Runs You may choose to wire your SPIRIT Communications System using either 4-pair business wiring materials or 2-pair customer convenience wiring materials. Each run from the controller to a telephone location should be numbered and labeled. Materials for labeling the wiring are included with the controller. Do not skip this important step. If you choose to wire your system with customer convenience wiring, use the labels provided to label EACH END of EVERY wiring run. Proceed to page...
Page 13
Step 4A Business (4-pair) Wiring n You may choose to wire your location with 4-pair business wiring to be ready for future communications needs. The materials you will need for this installation are available from your AT&T representative or authorized dealer. List of Materials You will need the following materials: screwdriver (flathead) scissors drill and bits appropriate for your walls l l l You will also need the following kits, available from your AT&T representative or authorized...
Page 14
n Mount Jack Panel Boxes Mount the jack panel boxes near the controller, creating a jack field. You will need one jack panel box for every six telephones in your system. If possible, the jack field should be two to six inches below the controller if the controller is wall-mounted. Mounting screws for the jack panel boxes are included in the wiring installation kit. If you are installing the boxes on a sturdy supporting structure, such as studs or cross members, attach the boxes directly to the walls....
Page 15
n Run Cable to all Telephone Locations Select a cable extension kit with the right length of cable (100 or 200 feet) for one cable run. For runs over 200 feet, run a 200-foot cable, terminate it in a modular connecting block, plug in another cable, and repeat, up to a maximum of 1000 feet. Select a Cable Extension Kit with the right length of cable (100 or 200 feet) for one cable run. For runs over 200 feet, you will have to run a 200 foot cable, terminate it in a modular connecting block, and plug in...
Page 16
nInstall Modular Connecting Blocks Install a modular connecting block at each telephone location Find the modular connecting block from the Cable Extension Kit and the cable installation tool from the Wiring Installation Kit. Choose the location for the connecting block according tothe figure. Cut the cable, making sure you allow at least4 inches extra. Fasten the cable to the connecting block as shown in steps A-K, below. Loosen screw. Remove cover and set aside. Use cable stripping part of cable...
Page 17
Cable clip CableTELEPHONE LOCATION Modular connecting block Route your other cables and terminate each one in a modular connecting block. Be sure to label both ends of each cable run identically. Typical cable installation for one telephone location. ‘ Identical labels i Finish your installation by routing cables to all other telephone locations and installing modular connecting blocks for each one. Be sure to label both ends of each cable run identically. Cable clip Dress the cables neatly through the...
Page 18
n l l l l Step 4B Wiring Run, Using Customer Convenience Wiring Customer convenience wiring materials are available at your local phone store. Different situations require different materials. For instance, if a telephone location is less than 25 feet from the controller, you may choose to buy a 25’ D4BU line cord and plug one end in the modular connecting block of the telephone and the other end in the corresponding modular connecting block in the controller. Use telephone wire clips to secure the...
Page 19
Typical Installation Using Customer Convenience Wiring Note to installers: The SPIRIT system requires a reversal in the station set wiring. This reversal is in the telephone (tinsel) cord that is packed with the telephone, so all other station set wiring should be straight. 14
Page 20
Step 5 Install Telephone Sets SPIRIT telephone sets are available in 6-Button and 24-Button models. The models are installed the same way. SPIRIT telephones are not like regular telephones and will not work if plugged directly into the Network Interface Jacks. Regular telephones will not work if they are plugged into the station jacks on your controller. Record Installation Date Turn the telephone over. Write the installation date on the label located on the bottom of the set above the base. n n...