Home
>
Lucent Technologies
>
Communications System
>
Lucent Technologies Lucent Call Centers Little Instruction Book For Advanced Administration
Lucent Technologies Lucent Call Centers Little Instruction Book For Advanced Administration
Here you can view all the pages of manual Lucent Technologies Lucent Call Centers Little Instruction Book For Advanced Administration. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 101
Lucent Call Center’s Little Instruction Book for advanced administration 585-210-936 Issue 1 December 1999 Multi-site applications 79 Administering multi-site ELAI Inflow vector When the receiving switch receives the interflow request, the call first routes to a VDN. The VDN maps the call to the receiving switch’s inflow vector. Inflow checking is enabled using conditional goto commands in the inflow vector. Call acceptance or denial is then executed using one of the vector commands listed...
Page 102
Multi-site applications 80 Administering multi-site ELAI Lucent Call Center’s Little Instruction Book for advanced administration 585-210-936 Issue 1 December 1999 Vector commands ELAI vector commands can be categorized in one of three ways: call acceptance, call denial, or neutral. Each is addressed in one of the following tables. To accept an interflow call, the receiving switch generates a call acceptance message if at least one of the vector conditions are true, shown in Table 3....
Page 103
Lucent Call Center’s Little Instruction Book for advanced administration 585-210-936 Issue 1 December 1999 Multi-site applications 81 Administering multi-site ELAI If the receiving switch decides it is unable to accept the interflow call, it executes one of the commands shown in Table 4 to deny the call. queue-to splitCall terminates to agent Call queued to split route-toTerminates to valid local destination Successfully seizes a non-PRI trunk Results in a Look-Ahead Interflow call...
Page 104
Multi-site applications 82 Administering multi-site ELAI Lucent Call Center’s Little Instruction Book for advanced administration 585-210-936 Issue 1 December 1999 The vector commands shown in Table 5 are considered neutral because they generate neither call acceptance nor denial messages. Table 5: Neutral Vector Commands Command Conditions adjunct routingAlways announcementAnnouncement unavailable check splitCall neither terminates nor queues collect ced/cdpd digitsAlways considerAlways - used...
Page 105
Lucent Call Center’s Little Instruction Book for advanced administration 585-210-936 Issue 1 December 1999 Multi-site applications 83 Administering multi-site ELAI Using the conditional interflow-qpos command To achieve FIFO results, Enhanced Look-Ahead Interflow adds a conditional vector command to LAI functionality. The interflow-qpos conditional command is used in a route-to or goto command. This conditional command applies interflow processes only to those calls that are not expected...
Page 106
Multi-site applications 84 Administering multi-site ELAI Lucent Call Center’s Little Instruction Book for advanced administration 585-210-936 Issue 1 December 1999 FIFO example The following are sample steps from a FIFO processing vector: 1. announcement 3501 2. wait-time 0 secs hearing music 3. queue-to skill 1 pri m 4. goto step 7 if interflow-qpos < 9 5. wait-time 30 secs hearing music 6. goto step 5 if interflow-qpos >= 9 7. route-to number 93031234567 with cov n if interflow-qpos = 1 8....
Page 107
Lucent Call Center’s Little Instruction Book for advanced administration 585-210-936 Issue 1 December 1999 Multi-site applications 85 Administering multi-site ELAI Setting the minimum expected wait time The minimum expected wait time (EWT) threshold is used to help determine which calls you want to be answered locally. Minimum EWT is used when the local agents (in the first split/skill to which the call is queued) are handling a significantly higher number of calls than you would prefer, and...
Page 108
Multi-site applications 86 Administering multi-site ELAI Lucent Call Center’s Little Instruction Book for advanced administration 585-210-936 Issue 1 December 1999 Tips on administering multi-site ELAI Keep the following in mind as you administer ELAI: nThe Look-Ahead Interflow and Basic Call Vectoring features must be enabled on the System Parameters Customer-Options form. nBoth the sending switch and receiving switch must have the Basic Call Vectoring and the Look-Ahead Interflow features...
Page 109
Lucent Call Center’s Little Instruction Book for advanced administration 585-210-936 Issue 1 December 1999 Multi-site applications 87 Administering multi-site ELAI For detailed information on administering ELAI call vectors for multi-site applications, please refer to the “Look-Ahead Interflow” chapter of the DEFINITY Enterprise Communications Server Call Vectoring/Expert Agent Selection (EAS) Guide.
Page 110
Multi-site applications 88 Performing daily maintenance Lucent Call Center’s Little Instruction Book for advanced administration 585-210-936 Issue 1 December 1999 Performing daily maintenance From the DEFINITY ECS, you can view or print the following reports to help monitor trunk traffic and performance and determine the cause of problems. nRegularly use the Display Events form and execute a display events command for the appropriate vectors. Vector events will identify and indicate the...