Page 431
DEFINITY Enterprise Communications Server and System 75 and System 85 Terminals and Adjuncts Reference 555-015-201Issue 11 December 1999 CALLMASTER Voice Terminals 13-11 13 the top feature button on the CALLMASTER VI, has a green status light associated with it. These buttons can be used for features assigned during administration. NOTE: The CALLMASTER V does not have any Feature-Only buttons. Listen-Only SPEAKER Only the CALLMASTER V has a one-way, listen-only speaker. If the user wishes to speak to the...
Page 432
DEFINITY Enterprise Communications Server and System 75 and System 85 Terminals and Adjuncts Reference 555-015-201Issue 11 December 1999 CALLMASTER Voice Terminals 13-12 13 When the user sets the volume for the headset or handset or for the tone ringer on the CALLMASTER II and III, IV, or on the CALLMASTER V, the display on the voice terminal shows a “bar array” that indicates the volume setting. LOG IN and RELEASE buttons On the CALLMASTER II, CALLMASTER III, and CALLMASTER IV, the LOG IN and RELEASE...
Page 433
DEFINITY Enterprise Communications Server and System 75 and System 85 Terminals and Adjuncts Reference 555-015-201Issue 11 December 1999 CALLMASTER Voice Terminals 13-13 13 CALLMASTER is administered as a 7405D with a D401 display, as a 7406D, or as any other set with a 1-line display format. The default is the 2-line display. To change this setting, see the DEFINITY ECS CALLMASTER II, CALLMASTER III, and CALLMASTER IV Voice Terminals Instructions for Programming the Options, 555-015-172. Other Physical...
Page 434
DEFINITY Enterprise Communications Server and System 75 and System 85 Terminals and Adjuncts Reference 555-015-201Issue 11 December 1999 CALLMASTER Voice Terminals 13-14 13 Cords A D8W-87 line cord and a Handset cord are provided with all CALLMASTER voice terminals. An EIA/TIA Data cord is also shipped in the box with the CALLMASTER VI set. Kneewell Adapter (602 CALLMASTER only) An optional adapter is available for connecting two headsets or handsets to the 602 CALLMASTER. This adapter allows the handset...
Page 435
DEFINITY Enterprise Communications Server and System 75 and System 85 Terminals and Adjuncts Reference 555-015-201Issue 11 December 1999 CALLMASTER Voice Terminals 13-15 13 Wiring Information on the CALLMASTER IV The CALLMASTER IV voice terminal works in both 4-wire and 2-wire DCP configurations. The table on the next page shows pin assignments for the line cord and jack block interface *U-T=“Tip” U-R = “Ring” Table 13-1. The DCP Line Interface for the CALLMASTER IV CONNECTOR BLOCK DCP JACK INTERFACE...
Page 436
DEFINITY Enterprise Communications Server and System 75 and System 85 Terminals and Adjuncts Reference 555-015-201Issue 11 December 1999 CALLMASTER Voice Terminals 13-16 13 The design of this product allows it to operate on either 2-wire or 4-wire DCP circuits. In order for the terminal to function properly in either 2-wire or 4-wire installations, there must be NO INTERCONNECTIONS between the wire pairs used for 2-wire and 4-wire operation. Bridging or paralleling of these pairs can result in damage to...
Page 437
DEFINITY Enterprise Communications Server and System 75 and System 85 Terminals and Adjuncts Reference 555-015-201Issue 11 December 1999 CALLMASTER Voice Terminals 13-17 13 Notes: These ranges can be extended to 5,000 feet (1524 m) for 24 AWG wire and 4,000 feet (1219 m) for 26 AWG wire with the use of a Data Link Protector. Refer to EXPOSED PORT PROTECTION . In 2-wire installations, the CALLMASTER III and CALLMASTER IV can be connected to a TN2181 port board. Distance Limitations for the CALLMASTER V...
Page 438
DEFINITY Enterprise Communications Server and System 75 and System 85 Terminals and Adjuncts Reference 555-015-201Issue 11 December 1999 CALLMASTER Voice Terminals 13-18 13 The CALLMASTER II, CALLMASTER III, and CALLMASTER IV can be used only with a DEFINITY ECS G3V3 and above. The CALLMASTER II and CALLMASTER III must be aliased as a 602 CALLMASTER. The CALLMASTER IV voice terminal can be administered as itself. The CALLMASTER V and CALLMASTER VI can be used only with a DEFINITY ECS Release 6.1 and...
Page 439
DEFINITY Enterprise Communications Server and System 75 and System 85 Terminals and Adjuncts Reference 555-015-201Issue 11 December 1999 CALLMASTER Voice Terminals 13-19 13 Figure 13-6. Button Numbering for Administering the 602 CALLMASTER Voice Terminal Connected to a System 75, a DEFINITY G1 or G3, or a DEFINITY ECS Drop 12 3 45 6 78 9ABC DEF MNO JKL GHI PRS TUVWXY *O# Oper Co nfere nce Trans fe r Hold Mute Me ssa ge Re lea se 5 * Feature Button #6 is preassigned as a Mute Button. It is recommended...
Page 440
DEFINITY Enterprise Communications Server and System 75 and System 85 Terminals and Adjuncts Reference 555-015-201Issue 11 December 1999 CALLMASTER Voice Terminals 13-20 13 Figure 13-7. Button Numbering for Administering the 602 CALLMASTER Voice Terminal Connected to a System 85 or a DEFINITY G2 Drop 123 456 789ABC DEF MNO JKL GHI PRS TUVWXY *O# Oper Conference Transfe r Hold Mute Messa ge 8 NOTE: The Hold Button is Button #1.Feature Button Assignments Button Assignments 3-12 13-30 12 7 11 6 10 5 9 3 8...