Page 131
DEFINITY Enterprise Communications Server and System 75 and System 85 Terminals and Adjuncts Reference 555-015-201Issue 11 December 1999 The 6400 Series Telephones 7-27 The 6416D+ and 6416D+M Telephones 7 Applications for the Modular 6416D+M Telephone Only If the Modular 6416D+M telephone is being used with a DEFINITY switch, the manner in which the telephone and the analog adjunct interact depends on the switch release to which your telephone is connected. (Your system manager can give you more...
Page 132
DEFINITY Enterprise Communications Server and System 75 and System 85 Terminals and Adjuncts Reference 555-015-201Issue 11 December 1999 The 6400 Series Telephones 7-28 The 6416D+ and 6416D+M Telephones 7 Speaker (Listen-Only) Feature The 6416D+ and 6416D+M telephones have a two-way speaker phone; however, the telephones can also be optioned instead for a 1-way, listen-only speaker. If this is the case, use the SPEAKER button on the front of the telephone for turning on and off the speaker. The Speaker...
Page 133
DEFINITY Enterprise Communications Server and System 75 and System 85 Terminals and Adjuncts Reference 555-015-201Issue 11 December 1999 The 6400 Series Telephones 7-29 The 6416D+ and 6416D+M Telephones 7 Call Appearance/Feature Buttons The 6416D+ and 6416D+M telephones have 16 call appearance/feature buttons, each equipped with a red and a green light. Usually, at least two of these buttons are administered as call appearances for the telephone ’s primary extension number, where calls are placed and...
Page 134
DEFINITY Enterprise Communications Server and System 75 and System 85 Terminals and Adjuncts Reference 555-015-201Issue 11 December 1999 The 6400 Series Telephones 7-30 The 6416D+ and 6416D+M Telephones 7 Below is a list of the 12 default softkey features assigned to the 6416D+ and 6416D+M telephones and the order in which they appear. On 6416D+ and 6416D+M telephones connected to a DEFINITY ECS Release 6.1 or later, the system manager can choose to administer alternate features for use with the...
Page 135
DEFINITY Enterprise Communications Server and System 75 and System 85 Terminals and Adjuncts Reference 555-015-201Issue 11 December 1999 The 6400 Series Telephones 7-31 The 6416D+ and 6416D+M Telephones 7 Table 7-6. Alternate Softkey Features on the 6416D+ and 6416D+M Connected to a DEFINITY ECS Release 6.1 and Later Abbreviation Feature AcctAccount Code Entry ADAbbreviated Dialing buttons (can be multiple AD buttons) CFrwdCall Forwarding All Calls CParkCall Park CPkUpCall Pickup CnLWCCancel Leave Word...
Page 136
DEFINITY Enterprise Communications Server and System 75 and System 85 Terminals and Adjuncts Reference 555-015-201Issue 11 December 1999 The 6400 Series Telephones 7-32 The 6416D+ and 6416D+M Telephones 7 Other Physical Features Pull-out tray Five quick reference cards are provided in the tray located under the base of every 6400 Series telephone. Handset The 6416D+ and 6416D+M telephones are equipped with an AJ2A handset which can accept either a handset or a headset. Dial pad The 6416D+ and 6416D+M...
Page 137
DEFINITY Enterprise Communications Server and System 75 and System 85 Terminals and Adjuncts Reference 555-015-201Issue 11 December 1999 The 6400 Series Telephones 7-33 The 6416D+ and 6416D+M Telephones 7 Ringing The 6416D+ and 6416D+M telephones have electronic tone ringing with eight possible ringing patterns which you can select by pressing the CONF button while on-hook. The loudness of the tone ringer can be controlled by the VOLUME “arrow” button. (The user must NOT be on a speakerphone call. If the...
Page 138
DEFINITY Enterprise Communications Server and System 75 and System 85 Terminals and Adjuncts Reference 555-015-201Issue 11 December 1999 The 6400 Series Telephones 7-34 The 6416D+ and 6416D+M Telephones 7 A D8W modular cord MUST be used for all 2-wire installations requiring auxiliary power. If using an auxiliary power supply such as a Lucent Technologies 1151A, it is acceptable to have a D2R cord connected from the wall jack to the LINE jack found on the power supply. For 2-wire operation, if you need...
Page 139
DEFINITY Enterprise Communications Server and System 75 and System 85 Terminals and Adjuncts Reference 555-015-201Issue 11 December 1999 The 6400 Series Telephones 7-35 The 6416D+ and 6416D+M Telephones 7 Administration The 6416D+ and 6416D+M telephones can be administered as themselves on a DEFINITY system starting with Release 6.1 software. These telephones will NOT work with any DEFINITY switch release prior to Release 6.1. Button Numbering The following button diagrams of the 6416D+ and 6416D+M...
Page 140
DEFINITY Enterprise Communications Server and System 75 and System 85 Terminals and Adjuncts Reference 555-015-201Issue 11 December 1999 The 6400 Series Telephones 7-36 The 6416D+ and 6416D+M Telephones 7 Administering the Analog Adjunct on the Modular 6416D+M Telephone As noted above, all 6416D+ and 6416D+M can be administered as themselves ONLY IF they are connected to a DEFINITY ECS Release 6.1 (or later). In Native Mode the Modular 6416D+M telephone is administered through a digital line circuit...