Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Administration For Network Connectivity Instructions Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 281
Networking Screens 261 Administration for Network Connectivity 555-233-504— Issue 1 — April 2000 CID: 77730 A Screens Reference When adding an access endpoint with the ITC administered as restricted, its associated port can be a channel from a DS1 circuit pack with Zero Code Suppression administered as zcs or b8zs. For an existing access endpoint, ITC can only be changed from restricted to unrestricted if its associated port is a channel of a DS1 circuit pack with its Zero Code Suppression field...
Page 282
Networking Screens A Screens Reference Administration for Network Connectivity CID: 77730 555-233-504 — Issue 1 — April 2000 262 Data Module — Type ethernet Use the ethernet data module type to define an interface between port 17 on the C-LAN board and the LAN. This data module associates a link number and extension number with the C-LAN port address. Common FieldsSee Common Data Module Fields (256) for descriptions of fields on this screen that are not listed below. Network uses 1’s for broadcast...
Page 283
Networking Screens 263 Administration for Network Connectivity 555-233-504— Issue 1 — April 2000 CID: 77730 A Screens Reference Data Module — Type ppp Use the ppp data module for direct point to point TCP/IP connections between DCS nodes. This data module associates a link number and destination node with the port address and node name for the local node. The fields on this form can be changed only when the corresponding port on the C-LAN circuit pack has been busied-out. Common FieldsSee Common...
Page 284
Networking Screens A Screens Reference Administration for Network Connectivity CID: 77730 555-233-504 — Issue 1 — April 2000 264 The valid subnets for each Class of address are: Notice that all 5 valid Class C subnet masks can also be valid Class B or Class A subnet masks, and all 13 valid Class B subnet masks can also be valid Class A subnet masks. For example, 255.255.255.224 is a valid subnet mask for all three address classes. It allows 6 (2 3-2) subnetworks for Class C addresses, 2046 (211-2)...
Page 285
Networking Screens 265 Administration for Network Connectivity 555-233-504— Issue 1 — April 2000 CID: 77730 A Screens Reference Destination DigitsUsed to enable access to the correct trunk group at the far end of the connection. This is typically the trunk access code (TAC) plus the extension of data module on the far end. If you use just the extension, then you must administer UDP and AAR route patterns to access the correct trunk group. Destination Node NameName of the node at the far end of this...
Page 286
Networking Screens A Screens Reference Administration for Network Connectivity CID: 77730 555-233-504 — Issue 1 — April 2000 266 Data Module — Type procr-intf (used for BX.25 connections with the si model) Use the procr-intf data module type to define an interface between the Processor Interface circuit pack and the DS1 facilities carrying the X.25 data for the connection to far end switch. This data module associates a link number with a physical channel number and extension number for the PI port...
Page 287
Networking Screens 267 Administration for Network Connectivity 555-233-504— Issue 1 — April 2000 CID: 77730 A Screens Reference Common FieldsSee Common Data Module Fields (256) for descriptions of fields on this screen that are not listed below. Physical ChannelA number used by the switch software to identify the physical channel. Maintenance ExtensionThe extension used to perform maintenance functions on the standby physical channel in a duplicated system. This is the extension specified on the dial...
Page 288
Networking Screens A Screens Reference Administration for Network Connectivity CID: 77730 555-233-504 — Issue 1 — April 2000 268 Assigned Member Ext and NameDisplay only. Extension and name of a previously administered user who has an associated Data Extension button and who will share the use of the module. ClockingDisplays only when the Destination Number field is set to eia (and Link = 1). This field sets the clocking for the physical layer of the protocol. Valid Value Usage internal, external...
Page 289
Networking Screens 269 Administration for Network Connectivity 555-233-504— Issue 1 — April 2000 CID: 77730 A Screens Reference Data Module - type X.25 (used for BX.25 connections with the r model) This form applies only to the r model. Common FieldsSee Common Data Module Fields (256) for descriptions of fields on this screen that are not listed below. Baud RateSpecifies the data transmission rate for this connection. Endpoint TypeMust be assigned as adjunct. An endpoint type is a type of packet...
Page 290
Networking Screens A Screens Reference Administration for Network Connectivity CID: 77730 555-233-504 — Issue 1 — April 2000 270 Error Logging?Used to record X.25 protocol errors in the hardware error log. Permanent Virtual Circuit?Indicates that the logical channels for PVC are allowed for this port; default is y (cannot be changed). Switched Virtual Circuit?Indicates that the Switched Virtual Circuit is not allowed for this port; default is n (cannot be changed). Highest PVC Logical...