Page 71
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 Hardware Configurations Page 2-5 Carriers in Multi-Carrier Cabinets 2 Port Carrier (J58890BB) Table 2-2 describes the function of each carrier slot. Table 2-2. Port Carrier Circuit Pack Slots Error Code Circuit PackTest Result Description/ Recommendation POWER UNIT (right side)Power Unit (+5V)649A Required for DC-powered systems. TRI PLS OUTPUT DC-Powered POWER UNIT/...
Page 72
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 Hardware Configurations Page 2-6 Carriers in Multi-Carrier Cabinets 2 Expansion Control Carrier (J58890AF) The Expansion Control Carrier is located in position A of each EPN. Table 2-3 describes the function of each carrier slot. Table 2-3. Expansion Control Carrier Slots Slot Name Circuit Pack Code Notes POWER UNIT (left side)Power Unit (+5V)631DA1 Required for AC-powered...
Page 73
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 Hardware Configurations Page 2-7 Carriers in Multi-Carrier Cabinets 2 Switch Node Carrier (J58890SA) Switch Node carriers house the components of a Center Stage Switch (CSS). The first switch node is located in carrier E of the PPN. If duplicated in a Critical Reliability configuration, its duplicate is located in carrier D of the PPN. The second switch node is located in carrier...
Page 74
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 Hardware Configurations Page 2-8 PNC Cabling — Fiber Hardware 2 PNC Cabling — Fiber Hardware The term “fiber” is used to refer to all the hardware needed for the three basic types of connections used to form multi-PN systems. Fiber administration specifies the endpoints to be connected, optional DS1 CONV locations, and parameters for DS1 Facility Line encoding and equalization....
Page 75
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 Hardware Configurations Page 2-9 PNC Cabling — Fiber Hardware 2 Figure 2-2. Fiber Link Connection Hardware To I/O Connector Plate 9823-Type Lightwave Transceiver9823-Type Lightwave Transceiver TX RXTX RX To I/O Connector PlateFL2P-P-xx Fiber-Optic Cables FL2P-P-xx Fiber-Optic Cables FL2P-P-xx Fiber-Optic Cables To I/O Connector PlateTX RX TX RX9823-Type Lightwave Transceiver...
Page 76
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 Hardware Configurations Page 2-10 PNC Cabling — Fiber Hardware 2 EI-to-SNI or EI-to-EI Intracabinet Metallic Cabling Metallic cable may be substituted for optical cable for “fiber” connections between EIs or between an EI and an SNI in the same MCC cabinet. The same I/O plate connectors are used. The metallic cables should not be used for intercabinet connections, since doing so...
Page 77
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 Hardware Configurations Page 2-11 PNC Cabling — Fiber Hardware 2 The DS1 CONV to EI/SNI cable is a shielded metallic Y-cable held in place at the EI/SNI port connector by a 4B retainer and at the DS1 CONV port connector by a 4C retainer. The cable end with one 25-pair amphenol connector attaches to the I/O Plate connector for the EI or SNI. The end with two 25-pair amphenol...
Page 78
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 Hardware Configurations Page 2-12 Circuit Packs 2 Figure 2-3. Typical DS1 CONV Connections to Remote EPNs 1. Place duplicate pairs in different carriers. 2. When removing two or more, the maximum cable distance between any two remoted end points is 100 miles (161 km). For example, if the EPN is 75 miles (121 km) from the PPN, then EPN 2 can only be 25 miles (40.2 km) from the...
Page 79
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 Hardware Configurations Page 2-13 Circuit Packs 2 Table 2-5. Circuit packs and modules supported by DEFINITY Apparatus Code Name Type 631DA1 AC Power Unit Power 631DB1 AC Power Unit Power 644A1 DC Power Unit Power 645B1 DC Power Unit Power 649A DC Power Unit Power 676B DC Power Supply Power 982LS Current Limiter Power CFY1B Current Limiter Power CPP1 Memory Expansion Control...
Page 80
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 Hardware Configurations Page 2-14 Circuit Packs 2 TN459B Direct Inward Dialing Trunk Port TN464C/D/E/F DS1 Interface - T1, 24 Channel - E1, 32 Channel Port TN465/B/C Central Office Trunk Port TN467 Analog Line Port TN468B Analog Line Port TN479 Analog Line Port TN497 Tie Trunk Port TN553 Packet Data Line Port TN556/B ISDN-BRI 4-Wire S/T-NT Line (A-Law) Port TN570/B/C Expansion...