Page 61
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 Maintenance Architecture Page 1-35 Protocols 1 Frequency Response Table 1-9 lists the analog-to-analog frequency response for station-to-station or station-to-CO trunk, relative to loss at 1 kHz for the United States. Table 1-10 lists the analog-to-digital frequency response of the system for station or CO-trunk-to-digital interface (DS0), relative to loss at 1 kHz for the United...
Page 62
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 Maintenance Architecture Page 1-36 Protocols 1 Insertion Loss for Port-to-Port; Analog or Digital Table 1-11 lists the insertion loss in the system for different connection types for the United States. Table 1-12 shows the overload and cross-talk characteristics. Intermodulation Distortion Table 1-13 lists the intermodulation distortion in the system for analog-to-analog and...
Page 63
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 Maintenance Architecture Page 1-37 Protocols 1 Quantization Distortion Loss Table 1-14 lists the quantization distortion loss in the system for analog port to analog port. Table 1-15 lists the quantization distortion loss in the system for analog port to digital port and digital port to analog port. Terminating Impedance: 600 Ohms nominal Trunk balance impedance (selectable): 600...
Page 64
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 Maintenance Architecture Page 1-38 Service Codes 1 ERL and SFRL Talking State Echo-Return Loss (ERL) and Single-Frequency Return Loss (SFRL) performance is usually dominated by termination and/or loop input impedances. The system provides an acceptable level of echo performance if the ERL and SFRL are met. Peak Noise Level nAnalog to analog — 20 dBrnC (decibels above reference...
Page 65
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 Maintenance Architecture Page 1-39 Facility Interface Codes 1 n9.0Y — Totally protected terminal equipment The product line service code is 9.0F indicating it is terminal equipment with fully protected premises wire at the private line ports. Facility Interface Codes A Facility Interface Code (FIC) is a five-character code (United States only) that provides the technical...
Page 66
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 Maintenance Architecture Page 1-40 Multimedia Interface (MMI) 1 Multimedia Interface (MMI) The Multimedia Interface handles the following protocols: nInternational Telecommunications Union (ITU) H.221 — Includes H.230, H.242, H.231, and H.243 protocol nAmerican National Standards Institute (ANSI) H.221 — Includes H.230, H.242, H.231, and H.243 protocol nBONDING (Bandwidth On Demand...
Page 67
Hardware Configurations Page 2-1 Multi-Carrier Cabinet 2 DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 2 2Hardware Configurations The DEFINITY System supports a variety of configurations consisting of a PPN and up to 21 EPNs. In addition, the system may use a Center Stage Switch (CSS) consisting of one or two Switch Nodes. This chapter describes the PPN and EPN cabinets, and the configuration of carriers and circuit packs...
Page 68
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 Hardware Configurations Page 2-2 Multi-Carrier Cabinet 2 n-48V DC battery plant nGlobal MCC uses 50-60 Hz at 200-240 VAC power source Figure 2-1. Multicarrier Cabinet (J58890A) Configurations Processor Port Network Cabinet The PPN cabinet, pictured above, is the primary cabinet in all G3r systems. It contains the Switch Processing Element (SPE) that controls the system and one Port...
Page 69
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 Hardware Configurations Page 2-3 Carriers in Multi-Carrier Cabinets 2 If the system has a Center Stage Switch, the E position holds a Switch Node Carrier. In a CSS system with duplicated PNC, the D position holds a Switch Node Carrier that duplicates the one in E position. In large systems requiring a CSS with two Switch Nodes, the second SN is located in an EPN cabinet, for both...
Page 70
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 Hardware Configurations Page 2-4 Carriers in Multi-Carrier Cabinets 2 Table 2-1 describes the function of each slot in the PPN Control Carrier. Table 2-1. PPN Control Carrier Circuit Pack Slots Slot Name Circuit Pack Code Notes POWER UNIT (right side)Power Unit (+5V)649A Required for DC-powered systems. TRI PLS OUTPUT DC-Powered cabinets SYS ACCESS/ MAINTENANCESystem Access and...